1. Catalogs
  2. Hypro Pressure Cleaning
  3. 1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual

1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual

1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual

1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual

Product catalog summary
General Description: The Hypro Series 1541A-SP is a gas engine-driven, self-priming centrifugal pump designed for high-capacity liquid transfer tasks, including water, liquid fertilizers, and compatible chemicals. It is ideal for de-watering applications.
Specifications:
  • Max Flow Rate: 87 GPM
  • Max Pressure: 40 PSI
  • Max Total Head: 92 FT
  • Max Suction Lift: 10 FT
  • Ports: 2" BSP Inlet and Outlet
  • Engine: PowerPro™ 2.5 HP
Safety Information:
  • Avoid pumping flammable or explosive fluids.
  • Do not exceed recommended speed, pressure, and temperature (140˚ F).
  • Secure discharge lines before starting the pump.
  • Regularly inspect hoses and connections.
  • Protect the pump from freezing conditions.
  • Ensure proper ventilation when operating the gasoline engine.
Installation and Operation:
  • Check fuel and oil levels before starting.
  • Prime the pump by filling the chamber with liquid.
  • Start the engine following specified choke and throttle settings.
  • Adjust engine speed according to the application.
Maintenance and Storage:
  • Flush the pump with water or a neutralizing agent before servicing.
  • Drain and clean the pump to prevent corrosion.
  • Store in a clean, dry environment.
Repair Instructions:
  • Carefully disassemble the pump, noting part orientation.
  • Replace worn or damaged components like seals and impellers.
  • Reassemble the pump, ensuring proper clearance between parts.
Troubleshooting:
  • Check for air leaks, blockages, or mechanical seal failures if performance issues arise.
Performance Data: The pump's performance varies with fluid density and viscosity, with a maximum flow rate of 87.2 GPM at 5 PSI.
Parts List: A detailed list of parts with reference numbers and descriptions is provided for maintenance and repair purposes.
Warranty: Hypro offers a limited warranty covering defects in material and workmanship under normal use for one year, with specific terms for different components.
Warranty Overview: Hypro provides a warranty that covers repair or replacement of products at their discretion. This warranty is exclusive and does not cover incidental or consequential damages.
Return Procedures: Products must be flushed of chemicals and labeled before returning to Hypro. A Material Safety Data Sheet may be requested. Hypro reserves the right to dispose of products with unknown substances or charge for testing and disposal.
Technical and Warranty Assistance: For assistance, contact Hypro's technical or service numbers. Provide details such as model number, purchase date, and a description of the problem, including liquid type, temperature, suction lift, discharge pressure, and more.
Shipping Instructions: Obtain a return material authorization before sending products. Ensure shipping charges are prepaid and hazardous materials are properly identified to avoid fines or penalties.
See more

Catalog excerpts

1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual-2

Basket Strainer The basket strainer supplied with this pump is to be used when transferring solutions that may contain debris and solids which could become lodged in the pump or damage the impeller. Because of the high flow capacity of this pump, unknown debris could be siphoned off the bottom of the tank. Install the strainer on the suction side of the pump whenever possible to avoid pump damage. Please Note: It is illegal to ship or transport any hazardous chemicals without United States Environmental Protection Agency Licensing. 1.Always drain and flush pumps before servicing ordisassembling...

 Open the catalog to page 2
1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual-3

Note: Pump must not be run dry. Make sure there is water in the priming chamber. > 1.Stop pump for a short time: Run engine throttled all the way down (fully to the right). Turn engine switch to OFF position.2.Stopping pump for storage:Turn fuel cock to OFF position instead of turning the engine switch off. Let the engine idle for 2 to 3 minutes until fuel in carburetor is depleted and engine stops. If a valve is installed on the discharge hose, you may run pump with valve closed during this procedure. > 1.Drain pump. Flush Pump after Use.One of the most common causes for faulty pump performance...

 Open the catalog to page 3
1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual-5

Performance Data is based on testing with water.Performance will vary with fluid density and/or viscosity. 5PSI10 PSI15 PSI20 PSI25 PSI30 PSI35 PSI40 PSI >

 Open the catalog to page 5
1541A 2" Aluminum Transfer Pump with 2.5 HP PowerPro Engine Operation, Installation & Parts Manual-8

Hypro ("Hypro") warrants to the original purchaser of its products (the "Purchaser") that such products will be free from defects in materialandworkmanship under normal use for the period of one (1) year for all products except: oil crankcase plunger pumps will be free fromdefects in material and workmanship under normal use for the period of five (5) years, and accessories will be free from defects in materialand workmanship under normal use for the period of ninety (90) days. In addition, Hypro warrants to the purchaser all forged brass pump manifolds will be free from defects in material and...

 Open the catalog to page 8

All Hypro Pressure Cleaning catalogs and technical brochures

  1. PRODUCT CATALOG

    236  Pages

  2. Gear Driven

    3  Pages

  3. 9302 Series

    2  Pages

Archived catalogs

  1. 2535S OIPM

    12  Pages

  2. Cleanload OIPM

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.