Catalog excerpts

DS-4*7 / 4*2-1

Pressure Switches nyaropa®- HYDROSTAR

 Open the catalog to page 1
DS-4*7 / 4*2-2

DS-4*7/4*2 The Pressure Switch for Safety Switching DGBM-Roll-No. G. 9212767.3 Reduction of faults, caused by Micro-Switches, to a minimum. Statistically up to 106 switching cycles without faulty switching. Fully interchangeable to DS-307/302. - Same dimensions. Electrical lifetime considerably increased. 2 Micro-Switches with a) different contact design b) different contact material. All mounting dimensions like DS-307/302 Preferred application: air craft plants, lifting platforms ... Electrical Connection Switching symbols without pressure DS-417 double NOC 2 1 Function pressure increase Function...

 Open the catalog to page 2
DS-4*7 / 4*2-3

Pressure Switch, Characteristics DS-4*7 DS-4*7 1. General Design Connection Adjustment Safety Mounting position 2. Hydraulic data Switching pressure range Switching accuracy Ambient temperature Fluid 3. Electric data Switch Spring-loaded piston, because of mechanical turn is possible to get the spring screwed on “block” Thread G ¼ female or subplate, pitch circle ø 44 mm Adjustable screw top or knurled knob Locking screw 20-150 bar Variations of less than 1% - 40 °C bis + 90 °C Oil, oil-in-water-emulsion Electro-mechanical double-throw switch or, resp., double NCC or double NOC for standard performance:...

 Open the catalog to page 3
DS-4*7 / 4*2-4

Standard DS-4*7/4*2 S = Viton®fluoroelastomers G = 2 tapped holes B = 2 mounting holes SL = silver contacts Additionals notes = Flange mounting F = Pressure Switch with integrated F/P 90°-subplate (p max. = 350 bar) = scale and knurled knob V2 AS-H2** = with lock E 10 H2 SCH** = panel mounting = lead seal (not for version PO with scale) = brass housing MS** = special sealing (low function) SS** only for following pressure ranges: 5- 55 bar 10-100 bar 40-240 bar 20-350 bar Viton® is a registered trademark of DuPont Performance Elastomers. NOTE ! The unit may only be installed by technical specialists....

 Open the catalog to page 4

All Hydropa catalogs and technical brochures

  1. DS-307 / 302

    8  Pages

  2. DS-507 / 502

    8  Pages

  3. DS-802/M/B

    2  Pages

  4. WE 10 AH

    11  Pages

  5. 2 SPG

    9  Pages

  6. ZAH10 DR

    1  Page

  7. WE6AH

    14  Pages

  8. DMH-630 R

    11  Pages

  9. Hand pumps

    12  Pages

  10. ZA 6 RE -*

    1  Page

  11. Z 6 R *

    1  Page

  12. ZN 6 DMD - *

    1  Page

  13. ZN 6 DB - *

    1  Page

  14. ZN 6 DR-*

    4  Pages

  15. 3 SP-B

    4  Pages

  16. 2 SP-B

    4  Pages

  17. 1 SP-B

    4  Pages

  18. DS-4*7/4*2

    4  Pages

Archived catalogs

  1. DS-117/112

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.