GB505D

GB505D

GB505D

Product catalog summary
Overview: The Hydraulics International, Inc. (HII) air driven gas booster is designed to increase gas pressure from 50 psi (3.4 bar) to 6000 psi (414 bar). It can be powered by a low-pressure air compressor or high-pressure air storage such as SCUBA, SCBA, or nitrogen bottles. The booster operates with a dry, hydrocarbon-free high-pressure section, separated from the drive section.
Key Features:
  • Boosts gas pressure from 50 psi to 6000 psi.
  • Can hold pressure indefinitely without power consumption and restart under full load.
  • Intrinsically safe due to compressed air operation, reducing risks of heat, flame, spark, or electrical shock.
  • Contamination-free operation with separation between drive and gas sections using static seals and dual vents.
Optional Controls:
  • GB505D increases the number of fills by up to 50% and eliminates cascading, allowing filling from storage as low as 50 psi.
Applications: Ideal for general aviation, municipal fire, rescue, recreational and technical divers, dive shops, yachts, and rescue services.
Performance:
  • Low pressure air controls include a filter and on/off valve.
  • High pressure air controls feature an HP regulator, relief valve, and on/off valve.
  • Gas fill accessory kit includes inlet and outlet hose assemblies with connectors, filter, valve, gauge, and bleeder.
  • Watertight protective case with wheels, dimensions: 22”L x 14”W x 9”H (559 mm x 356 mm x 229 mm).
  • Safety low and high-pressure pilot valves automatically stop and restart the booster.
  • Outlet pressure relief valve included.
Specifications:
  • Model 3G-DS-29: Weight 20 lbs (9 kg), Boost displacement per cycle 1.12 in³ (18.4 cm³), Maximum pressure 6000 psi (414 bar).
  • Model 3G-TS-9/29: Weight 22 lbs (10 kg), Boost displacement per cycle 1.77 in³ (29 cm³), Maximum pressure 6000 psi (414 bar).
Performance Curve: The performance curve indicates gas outlet flow rates and pressures for different models, showing efficiency and capacity under various conditions.
See more

Catalog excerpts

GB505D-1

COMPACT GAS BOOSTER SERIES 3G Hydraulics International, Inc. (HII) air driven gas booster is designed to boost gas from as low as 50 psi (3.4 bar) up to 6000 psi (414 bar). The unit may be driven with a low pressure conventional air compressor or regulated high-pressure air storage supply (SCUBA, SCBA or NITROGEN bottles). The high-pressure sections of the booster operate dry, hydrocarbon-free with complete separation from drive section. IDEAL FOR GENERAL AVIATION, MUNICIPAL FIRE, RESCUE, RECREATIONAL & TECHNICAL DIVERS, DIVE SHOPS, YACHTS AND RESCUE SERVICES OPTIONAL CONTROLS: KEY BENEFITS: Increase Number of Fills: Up to 50% Eliminate Cascading: Allows you to fill or top-off Low Pressure Air Controls Filter and on/off valve High Pressure Air Controls HP regulator, relief valve and on/off valve Gas Fill Accessory Kit Includes inlet 5-foot hose assembly with CGA connector; outlet 5-foot hose assembly with high pressure filter, on/off valve, gauge, and DIN/CGA connector with bleeder Watertight Protective Case with Wheels 22”L x 14”W x 9”H (559 mm x 356 mm x 229 mm) Boost gas pressure from 50 psi to 6000 psi Hold Pressure. Can be controlled to stop at any predetermined pressure and hold that pressure indefinitely without consuming power, and restart under full load Intrinsically Safe. Compressed air reduces risk of heat, flame, spark, or electrical shock Contamination FREE. Separation between drive and gas section uses three static seals with dual vents Safety Low & High Pressure Pilot Valves Set to automatically stop & restart the booster Outlet Pressure Relief Valve PERFORMANCE: Approximate fill-time* for a 19-ft3 (0.54-m3) O2 Bottle to 3,000-psi (207 bar) SYSTEM PRESSURE AFTER EQUALIZATION APPROX. FILL-TIME APPROX. FILL RATES *Based on 100-psi shop air and 80 cycles per minute. NOTE: DO NOT exceed 200 psi/min. transfer rate for pure oxygen and 50 -70 psi /min. during mixing. HYDRAULICS INTERNATIONAL, INC.® (HII) 9201 Independence Ave., Chatsworth, CA 91311 USA (Phone) 818.407.3400 | (Fax) 818.407.3428 www.hiigroup

 Open the catalog to page 1
GB505D-2

SPECIFICATIONS: Model Maximum Pressure Boost Displacement Per Cycle Drive Section Boost Section PERFORMANCE CURVE (Assume an air drive source of approximately 100 psi from 1/4” I.D. piping operating at maximum speed) 3G-DS-29 A GAS OUTLET FLOW - SCFM (NL/MIN) GAS OUTLET FLOW - SCFM (NL/MIN) Dashed lines represent approximate air consumption: A : 4 SCFM B : 7 SCFM C : 10 SCFM D : 13 SCFM (113 NL/MIN) (198 NL/MIN) (283 NL/MIN) (368 NL/MIN) Dashed lines represent approximate air consumption: A : 4 SCFM B : 7 SCFM C : 10 SCFM D : 13 SCFM (113 NL/MIN) (198 NL/MIN) (283 NL/MIN) (368 NL/MIN) HYDRAULICS...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.