Overview: The document discusses SanRO membranes by Hydranautics, designed for use in USP classified water systems, particularly in pharmaceutical and cosmetic applications. These membranes are engineered to prevent bacterial growth and ensure high ion removal efficiency with minimal fouling.
Key Features:
  • SanRO Membranes: These are high-performance membranes conforming to FDA Regulation CFR, Title 21, suitable for USP water purification systems.
  • SanRO-HS and SanRO-HS2: These are heat-sanitizable membranes designed for sanitization at 85°C, offering convenience by eliminating the need for chemical handling.
Specifications:
  • Membrane Configuration: Sanitary spiral wound with composite polyamide polymer.
  • Maximum Applied Pressure: 600 psi (4.14 MPa).
  • Operating Temperature: Up to 113°F (45°C).
  • pH Range: Operating range of 3.0 - 10.0, cleaning range of 2.0 - 11.0.
Performance Data:
  • Nominal System Performance: Applied pressure and permeate TDS values are provided for various SanRO models, indicating their efficiency in different conditions.
  • Element Performance: Detailed performance metrics for different SanRO models, including permeate flow rates and rejection percentages.
Applications: The membranes are suitable for bulk pharmaceutical process water, cosmetic formulations, and container rinsing, ensuring compliance with USP 24 water purified classifications.
Additional Information: The document includes contact details for Hydranautics and notes on packaging and liability, emphasizing the user's responsibility to determine product suitability for specific applications.
See more

Catalog excerpts

SanRO®-2

Configuration . . . . . . . . . . . . . . . . . . . . . .Sanitary Spiral WoundMembrane Polymer . . . . . . . . . . . . . . . . .Composite PolyamideMaximum Applied Pressure, psi (MPa) . . . . . . . . . . .600 (4.14) Maximum Pressure Drop per Vessel, psi (MPa) . . . . . .60 (0.41)Maximum Pressure Drop per Membrane, psi (MPa) . . .10 (0.07)Maximum Chlorine Concentration, PPM . . . . . . . . . . . . . . .<0.1 Maximum Operating Temperature, ٰF (C) . . . . . . . . . .113а(45)Operating pH Range . . . . . . . . . . . . . . . . . . . . . . . . . . .3.0 - 10.0Cleaning pH Range . . . . . . . . . . . . ....

 Open the catalog to page 2

All Hydranautics catalogs and technical brochures

  1. LFC3-LD

    2  Pages

  2. SWC5-LD

    2  Pages

  3. CPA5-LD

    2  Pages

  4. ESPA B MAX

    1  Page

  5. ESPA2-LD

    2  Pages

  6. Dairy10K

    2  Pages

  7. Dairy5K

    2  Pages

  8. RO Membranes

    2  Pages

  9. DairyUF®

    2  Pages

  10. DairyRO®

    2  Pages

  11. HYDRAcap®

    2  Pages

  12. ESNA

    2  Pages

  13. LFC

    2  Pages

  14. SWC

    2  Pages

  15. CPA

    2  Pages

  16. ESPA

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.