Product Overview: The ESPAB MAX is a spiral wound membrane element designed by Hydranautics for water treatment applications. It features a composite polyamide membrane with an active area of 440 ft2 (40.8 m2).
Performance Specifications: The membrane offers a permeate flow of 9,000 gallons per day (34.1 m3/d) and a salt rejection rate of 99.3% (minimum 99.0%). Typical boron rejection at pH 10 is 96.0%.
Application Data: The maximum applied pressure is 600 psig (4.16 MPa), with a chlorine concentration limit of less than 0.1 PPM. The membrane operates effectively at temperatures up to 113°F (45°C) and within a pH range of 2-11 for continuous use, extending to 1-12.5 for cleaning. Feedwater turbidity should not exceed 1.0 NTU, and the maximum feed flow is 75 GPM (17.0 m3/h). The concentrate to permeate flow ratio must be at least 5:1, and the maximum pressure drop per element is 10 psi.
Test Conditions: Performance data is based on initial testing after 30 minutes of operation using a 1500 PPM NaCl solution at 150 psi (1.05 MPa) and 77°F (25°C), with a permeate recovery of 15% and a pH range of 6.5-7.0. Boron testing involves a 10 mg/L boron solution adjusted to pH 10.
Physical Dimensions: The element measures 40.0 inches (1016 mm) in length, 7.89 inches (200 mm) in diameter, and 1.125 inches (28.6 mm) in core diameter, weighing 36 lbs (16.4 kg).
Packaging and Variability: Each membrane element is supplied with a brine seal, interconnector, and o-rings, packaged in a sealed polyethylene bag with less than 1.0% sodium meta-bisulfite solution, and enclosed in a cardboard box. Variability in permeate flow, membrane active area, and element weight is noted.
Disclaimer: Hydranautics provides this information in good faith but without guarantee, as usage conditions are beyond their control. Users must determine the suitability of the product for their specific applications.
See more

Catalog excerpts

ESPA B MAX-1

Membrane Element Permeate Flow: Salt Rejection: Boron Rejection (Typical)@ pH = 10: Configuration: Membrane Polymer: Membrane Active Area: Spiral Wound Composite Polyamide 2 2 440 ft (40.8m ) Application Data* Maximum Applied Pressure: Maximum Chlorine Concentration: Maximum Operating Temperature: pH Range, Continuous (Cleaning): Maximum Feedwater Turbidity: Maximum Feedwater SDI (15 mins): Maximum Feed Flow: Minimum Ratio of Concentrate to Permeate Flow for any Element: Maximum Pressure Drop for Each Element: * The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures. Test Conditions The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions: 1500 PPM NaCl solution 150 psi (1.05 MPa) Applied Pressure 77 F (25 C) Operating Temperature 15% Permeate Recovery 6.5 - 7.0 pH Range (For boron testing, 10 mg/L boron is added and pH adjusted to 10 with NaOH) PERMEATE CONCENTRATE A, inches (mm) 40.0 (1016) Notice: Permeate flow for individual elements may vary + or - 15 percent. Membrane active area may vary +/-4%. Element weight may vary. All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box. † When tested at standard test conditions with 5.0ppm Boron in feed solution. Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses. 10/07/13 Hydranautics Corporate: 401 Jones Road, Oceanside, CA 92058 1-800-CPA-PURE Phone: 760-901-2500 Fax: 760-901-2578 [email protected]

 Open the catalog to page 1

All Hydranautics catalogs and technical brochures

  1. LFC3-LD

    2  Pages

  2. SWC5-LD

    2  Pages

  3. CPA5-LD

    2  Pages

  4. ESPA2-LD

    2  Pages

  5. Dairy10K

    2  Pages

  6. Dairy5K

    2  Pages

  7. RO Membranes

    2  Pages

  8. SanRO®

    2  Pages

  9. DairyUF®

    2  Pages

  10. DairyRO®

    2  Pages

  11. HYDRAcap®

    2  Pages

  12. ESNA

    2  Pages

  13. LFC

    2  Pages

  14. SWC

    2  Pages

  15. CPA

    2  Pages

  16. ESPA

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.