6000-valve - 2

SECTIONAL CUTAWAY Parallel Passage Precision Load Check Work Port Feeder Cartridge with Anti-Void used as Cylinder Port Full Flow Relief A Lighter Centering Spring Design. "Less Operator Spool Design minimizes the Flow Force Effects on Spool Movement and also provides Superior Thru Neutral Pump Passage Tank Passage Seal/Wiper Combination to give long lasting Leak-Free Protection Patented One O-Ring Seal between sections — Leak-Free Design with Anti-Void used as Main Full Flow Relief

Open the catalog to page 2
6000-valve - 3

The Model 6000 sectional valve is a directional control valve designed for use with parallel, conventional and series circuit hydraulic systems, of open or closed center types. Model 6000 inlets, mid-inlets, outlets and spool sections provide a compact envelope to save Standard spool types include single acting, double acting, motor and double acting float, with non- standard custom designed spools available. Most design requirements can be met with a variety of work port options and end mechanisms. • "Zero leak" spool seals • 4000 psi maximum operating pressure — see page 6. • Open center...

Open the catalog to page 3
6000-valve - 4

The term "Low Effort" was associated with this spool type as a result of the successful design efforts to reduce the variety of flow forces on the spool during The machined notch design in detail A directs the fluid entering the spool land area in such a way as to create a reactionary force on the spool that reduces the force created by the high velocity. The machined notch in detail B cushions the exhausting fluid from the land area by directing the initial flow jet back against the housing land when the grooves are first exposed, then vertical to the spool axis as the groove completely...

Open the catalog to page 4
6000-valve - 6

PRESSURE DROP CURVES THROUGH NEUTRAL THROUGH NEUTRAL PSID INLET TO WORK PORT WORK PORT WORK PORT TECHNICAL DATA Maximum Rated Operating Pressure (Method of verifying rated fatigue pressure of the pressure containing envelope conforms to NFPA Recommended Std.. Vitron Optional WORK PORT TO TANK WORK PORT WORK PORT Maximum number of spool sections (any We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty We make no other warranty, expressed or implied. Performance characteristics shown are typical of...

Open the catalog to page 6
6000-valve - 7

MODEL 6000 VALVE ASSEMBLY INLET PORT MAIN RELIEF VALVE ASSf.- SHUT-Ofr PLUG ASST. -SHUT-OFF PLUG ASSY. -OUTLET PORT POWER BEYOND SPOOL DETAIL AND MOVE ME NT WORK PORT RELIEF VALVE ASSY.

Open the catalog to page 7
6000-valve - 8

INLET SECTION ASSEMBLIES WITH AUXILIARY PORT FOR MAIN RELIEF VALVE. END INLET AND SIDE GAGE PORT (PLUGGED) GAGE PORT USED IN SECTION©OF THE VALVE ASSEMBLY SPECIFICATION SHEET (Pg 30)

Open the catalog to page 8
6000-valve - 9

INLET/OUTLET SECTION ASSEMBLIES WITH AUXILIARY PORT FOR MAIN RELIEF VALVE. TOP INLET / OUTLET PORTS AND OPTIONAL END INLET / OUTLET PORTS USED IN SECTION©OF THE VALVE ASSEMBLY SPECIFICATION SHEET ( Pg 30) SEE PAGE 7 FOR ADDITIONAL DIMENSIONAL INFORMATION

Open the catalog to page 9
6000-valve - 10

MID-INLET SECTION ASSEMBLIES MUST BE ORDERED IN CONJUNCTION WITH ONE OF THE OPTIONS SHOWN (BELOW) OUTLET PORT INLET PORT /—O-RING SIDE CIRCUIT SHOWN WITH R.V. INSTALLED

Open the catalog to page 10
6000-valve - 11

PARALLEL CIRCUIT MANUALLY OPERATED SPOOL SECTION ASSEMBLIES FEATURES HUSCO PATENTED "LOW EFFORT" SPOOLS AND "ZERO LEAK" SPOOL SEALS LOAD CHECK SPRING P/N - 4628- LOAD CHECK POPPET P/N - 6023 LOAD CHECK OPTIONAL AUXILIARY NEUTRAL PASSAGE SPOOL SECTION ASSY PART No. VALVE PORTS STANDARD SPRING CENTERING FORCES USED IN SECT ION (2)OF THE VALVE ASSEMBLY SPECIFICATION SHEET < Pg 30 SEE PAGE 7 FOR ADDITIONAL DIMENSIONAL INFORMATION

Open the catalog to page 11
6000-valve - 12

PARALLEL CIRCUIT HYDRAULIC REMOTE SPOOL SECTION ASSEMBLIES FEATURES HUSCO PATENTED "LOW EFFORT" SPOOLS O-RING SIDE LOAD CHECK SPRING P/N - 46>28 LOAD CHECK POPPET P/N - 6023 NEUTRAL PASSAGE SPOOL SECTION ASSY PART No VALVE PORTS USED IN SECTION @ OF THE VALVE ASSEMBLY SPECIFICATION SHEET ( Pg 30) DIMENSIONAL INFORMATION APPROXIMATE PILOT PRESSURE VS SPOOL TRAVEL 20 PSI -- SPOOL STARTS TO SHIFT 80 PSI -- FLOW BEGINS AT WORK PORT 360 PSI -- FULL SHIFT. FULL WORK PORT PLOW 1000 PSI -- MAXIMUM PILOT PRESSURE USE WITH HUSCO MANUAL HYDRAULIC CONTROLLERS. STD SECTIONAL TYPE: P/N: 7470-Ai5 ( I...

Open the catalog to page 12
6000-valve - 13

PARALLEL CIRCUIT PNEUMATIC REMOTE SPOOL SECTION ASSEMBLIES FEATURES HUSCO PATENTED "LOW EFFORT" SPOOLS AND "ZERO LEAK" SPOOL SEALS LOAD CHECK SPRING P/N - 4628 LOAD CHECK POPPET P/N - 6023 O-RING SIDE-

Open the catalog to page 13
6000-valve - 14

CONVENTIONAL CIRCUIT MANUALLY OPERATED SPOOL SECTION ASSEMBLIES FEATURES HU5C0 PATENTED "LOW EFFORT" SPOOLS AND "ZERO LEAK" SPOOL SEALS LOAD CHECK SPRING P/N - 4628 LOAD CHECK POPPET P/N - 6023 SPRING CENTER SPOOL SECTION ASSY PART No. VALVE PORTS STANDARD SPRING CENTERING FORCES (DOESN'T APPLY TO AUTQ-K.O. SECTION USED IN SECT I ON (2)OF THE VALVE ASSEMBLY SPECIFICATION SHEET ( Pg 30 SEE PAGE 7 FOR ADDITIONAL DIMENSIONAL INFORMATION

Open the catalog to page 14
6000-valve - 15

SERIES CIRCUIT MANUALLY OPERATED SPOOL SECTION ASSEMBLIES FEATURES "ZERO LEAK" SPOOL SEALS LOAD CHECK SPRING P/N - 4628 LOAD CHECK POPPET P/N - 6023 LOAD CHECK O-RING SIDE SPOOL SECTION ASSY PART No. VALVE PORTS STANDARD SPRING CENTERING FORCES USED IN SECT ION (2)OF THE VALVE ASSEMBLY SPECIFICATION SHEET (Pg 30) SEE PAGE 7 FOR ADDITIONAL DIMENSIONAL INFORMATION

Open the catalog to page 15
6000-valve - 16

OUTLET SECTION ASSEMBLIES USED IN SECT I ON (3)OF THE VALVE ASSEMBLY SPECIFICATION SHEET ( Pq 30) REQUIRES UPSTREAM OUTLET PORT SOMEWHERE ELSE IN VALVE ASSY.

Open the catalog to page 16
6000-valve - 17

POWER BEYOND / CLOSED CENTER SECTION ASSEMBLIES TO CREATE A CLOSED CENTER CIRCUIT. PLUG POWER BEYOND PORT. REQUIRES AN UPSTREAM OUTLET PORT IN VALVE ASSY. ASSEMBLY SPECIFICATION SHEET ( Pg 30

Open the catalog to page 17
6000-valve - 18

UNIVERSAL OUTLET/POWER BEYOND OPTION SECTION ASSEMBLIES AUXILIARY VALVE PORT CIRCUIT OPTIONS CALL SOLD SEPARATELY) RELIEF VALVE INSTALLED SHUT-OFF PLUG INSTALLED (OPEN CENTER ) BEYOND PORT AUXILIARY PORT - TO CREATE A CLOSED CENTER CIRCUIT. PLUG POWER BEYOND PORT(S) AND INSTALL SHUT-OFF PLUG IN AUXILIARY PORT WITH 53203 HOLLOW HEX PLUG INSTALLED IN AUXILIARY PORT. ALL PORTS ARE COMMON TO OUTLET ASSEMBLY SPECIFICATION SHEET ( Pq 30) SEE PAGE 7 FOR ADDITIONAL DIMENSIONAL INFORMATION

Open the catalog to page 18

All Husco International catalogs and technical brochures

  1. SCX180

    32 Pages

  2. SCX300

    1 Pages

  3. VF1600e

    1 Pages

  4. VF1200

    1 Pages

  5. 5000-valve

    36 Pages

  6. 6400-valves

    1 Pages

  7. 6600-series

    2 Pages

  8. 7100-valve

    15 Pages

  9. 9210-valve

    6 Pages

  10. 9610-valve

    1 Pages

  11. Suspension

    1 Pages

  12. HEC-808

    2 Pages

  13. HVC

    1 Pages

  14. EHPV

    2 Pages

  15. 5000

    35 Pages

  16. VF1200e

    1 Pages

  17. VF1000

    1 Pages

  18. SCX120

    32 Pages