TP08

TP08

TP08

Product catalog summary
Introduction
TP08 is a small-sized, non-steady-state probe designed for measuring thermal conductivity or resistivity with high accuracy. It complies with ASTM D 5334-00, D 5930-97, and IEEE 442-1981 standards. The probe is suitable for various materials including soils, sediments, and foodstuffs. It uses the Non-Steady-State Probe (NSSP) method, which is fast and does not require critical sample sizes.

Design and Specifications
The TP08 is a smaller version of the TP02, designed for situations where the larger size of TP02 is impractical. It features a needle with a thermocouple junction and a heating wire. The probe measures power, time, and temperature directly, providing absolute measurements. The needle is 70 mm long with a diameter of 1.2 mm, suitable for samples around 80 ml. The probe operates effectively as long as a 20 mm radius around the needle is covered.

Standards and Calibration
TP08 adheres to ASTM and IEEE standards for thermal conductivity measurement. It can be integrated into measurement systems like the Campbell Scientific CR10X. Calibration can be verified using Calibration Reference Cylinders traceable to NPL. The probe is suitable for ISO certified labs.

Applications and Options
TP08 is ideal for studies involving ocean sediments, small samples, and high-cost samples like uranium sludge. It requires a minimum sample radius of 20 mm. Optional containers and guiding tubes are available for specific applications. The probe is protected to IP 68 standards, with the total sensor protected to IP 67.

Additional Information
For high accuracy calibration, CRC Calibration Reference Cylinders are available. The TP08 manual is available as a free PDF. For permanent soil installations, the TP01 model is recommended. Turnkey systems and additional solutions are available from Hukseflux.
See more

Catalog excerpts

TP08-1

TP08 SMALL SIZE NON-STEADY-STATE PROBE FOR THERMAL CONDUCTIVITY MEASUREMENT TP08 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level. It works in compliance with the ASTM D 5334-00, D 5930-97 and IEEE 442-1981 standards. The TP08 is a small version of type TP02, made for situations where the length of TP02 poses a problem. The standard TP08 probe has proven suitability in soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials. The Non-Steady-State Probe (NSSP) measurement method (also known as transient line source, thermal needle, hot needle, heat pulse- and hot wire technique) has the fundamental advantages that it is fast and absolute while the sample size is not critical. Hukseflux is specialised in NSSP design. Special models have been developed for in-situ field experiments. For permanent installation in soils, a dedicated model, TP01, is available. TP08 has been designed and tested in collaboration with the Applied Physics Group of Wageningen University. Figure 1 TP08 Small Size Non-Steady-State Probe: The probe consists of a needle (3) with a single thermocouple junction (6) and a heating wire, (5). It is inserted into the medium that is investigated. In the base, (2), a temperature sensor, (4), is mounted. All dimensions are in mm. INTRODUCTION The standards of the American Society for Testing and Materials (ASTM) and Institute of Electrical and Electronics Engineers (IEEE) describe proven methods for determining the thermal conductivity of materials. ASTM D 5334-00 and D 5930-97 and IEEE Std 442-1981 " Standard Test Methods" specify the use of Non-Steady-State Probes (NSSP) in various applications. In general a NSSP consists of a heating wire, representing a perfect line source, and a temperature sensor capable of measuring the temperature at this source. The probe is inserted in the medium that is investigated. The NSSP principle relies on a unique property of a line source: after a short transient period the temperature rise, ∆T, only depends on heater power, Q, and medium thermal conductivity, λ: ∆T = (Q / 4 π λ) (ln t + B) With ∆T in K, Q in W/m, λ in W/mK, t the time in s and B a constant. By measuring the heater power, and tracing the temperature in time (for TP08 typically during 2 minutes), λ can be calculated. The sample size is not critical, as long as a 20 mm radius around the needle is covered. The measurements of Q, t and ∆T are all direct measurements of power, time, and temperature respectively. These are done without need of reference materials. The measurement with TP08 is absolute. TP08 can be obtained as a separate probe for incorporation in the user's measurement and control system. It is suitable for operation with the Campbell Scientific CR10X. TP08 DESIGN Hukseflux specialises in Non-Steady-State probe design. The primary model of the Hukseflux product range is the TP02. This model offers optimal measurement accuracy by a combination of its design features. For some applications however the requirements regarding the sample size are such that the needle length and diameter of TP02 are too large. For this category of samples, TP08 has been designed. Having a needle length of 70 mm, with the junction at around 17 mm from the tip, and a diameter of 1.2 mm, samples of around 80 ml can be analysed. (35 mm depth). In some cases samples can even be smaller (consult Hukseflux). Version 0616 (page 1 of 2) Hukseflux reserve the right to alter specifications without prior notice HUKSEFLUX™ THERMAL SENSORS . WWW.HUKSEFLUX.COM . [email protected]

 Open the catalog to page 1
TP08-2

TP08 DESIGN (CONTINUED) In TP08 the reference junction of the thermocouple is located in the base. A high quality measurement with TP08 requires that not only the sample but also the base are at a stable (preferably the same) temperature. Usually this is achieved by clamping the base into the same material (metal) that holds the sample. MORE INFORMATION / OPTIONS Standards: ASTM standards can be obtained from ASTM at http://www.astm.org. Alternative designs: Hukseflux is specialised in NSSP design. Alternative models, for instance smaller, more robust or temperature resistant have been manufactured...

 Open the catalog to page 2

All Hukx catalogs and technical brochures

  1. SRA30-M2-D1

    3  Pages

  2. SR30-M2-D1

    7  Pages

Archived catalogs

  1. TRSYS20

    4  Pages

  2. SR25

    4  Pages

  3. SR15 series

    4  Pages

  4. TP02

    2  Pages

  5. TP01

    1  Page

  6. TRSYS01

    1  Page

  7. TNS01

    1  Page

  8. THISYS

    3  Pages

  9. WS01

    1  Page

  10. CRC series

    1  Page

  11. GT series

    2  Pages

  12. TPSYS02

    1  Page

  13. THASYS

    2  Pages

  14. IR02-TR

    1  Page

  15. DR01

    2  Pages

  16. ALUSYS

    1  Page

  17. SR11-TR

    1  Page

  18. NF02

    1  Page

  19. HFP01

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.