TP01
1 /1Page

TP01

TP01
1 /1Page

Catalog excerpts

TP01-1

TP01 THERMAL PROPERTIES SENSOR The TP01 is a sensor for the long-term monitoring of soil thermal conductivity, thermal diffusivity and heat capacity. TP01 is designed for long term (permanent) installation in soils. It covers the the thermal conductivity (λ) range of 0.3 to 4 W/m.K, which is sufficient for most anorganic soil types. The core of TP01 is a differential temperature sensor (2 thermopiles) (1) measuring the radial differential temperature with record breaking sensitivity. The sensor performs a temperature measurement around a heating wire (2). Both heating wire and sensor are incorporated in a very thin plastic foil. The low thermal mass makes it suitable for estimating thermal diffusivity (a). Dividing λ by the thermal diffusivity, a, gives the volumetric heat capacity Cv, which varies with water content. The thermopile signal minus the initial offset (U - U0) when heating with power Q depends on λ and a of the medium. U - U0 = ( Eλ Q / λ ) F( a t ) Eλ is a calibration constant, t is time, F is a function that equals 1 for large at. By looking at the steady state signal amplitude λ can be determined. Cv and a can be found by looking at the 63% response time for F. The detection of changes in Cv (and water content) is the strong point of TP01; the resolution is much better than the accuracy. The product manual can be obtained via e-mail. Programs for use with the Campbell Scientific CR10X and CR1000 are available. Hukseflux has a broad product range of sensors for thermal conductivity measurement; please consult the product catalogue. See also needle type probes: TP02 and TP08. SUGGESTED USE Scientific study of the heat storage as part of the surface energy balance Redundancy for soil moisture content TP01 SPECIFICATIONS Figure 1 above: TP01 sensor: thermopiles (1), heating wire (2), cable (3). Dimensions in mm. below: graphs in different soil types: signal amplitude varies with 1/ λ, signal response time varies with a. All dimensions are in mm. Temperature range: Sensor thickness (nominal): Required readout: 2 diff voltage channels 1 V , 5 mV range Voltage input (nominal): Typical heating cycle duration: Heating power / m (nominal): Version 0618 (page 1 of 1) Hukseflux reserve the right to alter specifications without prior notice HUKSEFLUX™ THERMAL SENSORS . WWW.HUKSEFLUX.COM . [email protected]

 Open the catalog to page 1

All Hukx catalogs and technical brochures

  1. SRA30-M2-D1

    3  Pages

  2. SR30-M2-D1

    7  Pages

Archived catalogs

  1. TRSYS20

    4  Pages

  2. SR25

    4  Pages

  3. SR15 series

    4  Pages

  4. TP08

    2  Pages

  5. TP02

    2  Pages

  6. TRSYS01

    1  Page

  7. TNS01

    1  Page

  8. THISYS

    3  Pages

  9. WS01

    1  Page

  10. CRC series

    1  Page

  11. GT series

    2  Pages

  12. TPSYS02

    1  Page

  13. THASYS

    2  Pages

  14. IR02-TR

    1  Page

  15. DR01

    2  Pages

  16. ALUSYS

    1  Page

  17. SR11-TR

    1  Page

  18. NF02

    1  Page

  19. HFP01

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.