TP01
1Pages

{{requestButtons}}

Catalog excerpts

TP01 - 1

TP01 THERMAL PROPERTIES SENSOR The TP01 is a sensor for the long-term monitoring of soil thermal conductivity, thermal diffusivity and heat capacity. TP01 is designed for long term (permanent) installation in soils. It covers the the thermal conductivity (λ) range of 0.3 to 4 W/m.K, which is sufficient for most anorganic soil types. The core of TP01 is a differential temperature sensor (2 thermopiles) (1) measuring the radial differential temperature with record breaking sensitivity. The sensor performs a temperature measurement around a heating wire (2). Both heating wire and sensor are incorporated in a very thin plastic foil. The low thermal mass makes it suitable for estimating thermal diffusivity (a). Dividing λ by the thermal diffusivity, a, gives the volumetric heat capacity Cv, which varies with water content. The thermopile signal minus the initial offset (U - U0) when heating with power Q depends on λ and a of the medium. U - U0 = ( Eλ Q / λ ) F( a t ) Eλ is a calibration constant, t is time, F is a function that equals 1 for large at. By looking at the steady state signal amplitude λ can be determined. Cv and a can be found by looking at the 63% response time for F. The detection of changes in Cv (and water content) is the strong point of TP01; the resolution is much better than the accuracy. The product manual can be obtained via e-mail. Programs for use with the Campbell Scientific CR10X and CR1000 are available. Hukseflux has a broad product range of sensors for thermal conductivity measurement; please consult the product catalogue. See also needle type probes: TP02 and TP08. SUGGESTED USE Scientific study of the heat storage as part of the surface energy balance Redundancy for soil moisture content TP01 SPECIFICATIONS Figure 1 above: TP01 sensor: thermopiles (1), heating wire (2), cable (3). Dimensions in mm. below: graphs in different soil types: signal amplitude varies with 1/ λ, signal response time varies with a. All dimensions are in mm. Temperature range: Sensor thickness (nominal): Required readout: 2 diff voltage channels 1 V , 5 mV range Voltage input (nominal): Typical heating cycle duration: Heating power / m (nominal): Version 0618 (page 1 of 1) Hukseflux reserve the right to alter specifications without prior notice HUKSEFLUX™ THERMAL SENSORS . WWW.HUKSEFLUX.COM . INFO@HUKSEFLUX.COM

Open the catalog to page 1

All Hukseflux Thermal Sensors B.V. catalogs and technical brochures

  1. SBG04

    5 Pages

  2. FHF06

    4 Pages

  3. TRSYS20

    4 Pages

  4. FHF05 series

    6 Pages

  5. HTR02 series

    3 Pages

  6. SRA01

    2 Pages

  7. RA01

    2 Pages

  8. VU01

    2 Pages

  9. SR25

    4 Pages

  10. SR30-M2-D1

    6 Pages

  11. SR15 series

    4 Pages

  12. TP08

    2 Pages

  13. TP02

    2 Pages

  14. TRSYS01

    1 Pages

  15. TNS01

    1 Pages

  16. THISYS

    3 Pages

  17. HF03 / LI19

    1 Pages

  18. HF02

    2 Pages

  19. ALUSYS

    1 Pages

  20. WS01

    1 Pages

  21. CRC series

    1 Pages

  22. GT series

    2 Pages

  23. TPSYS02

    1 Pages

  24. THASYS

    2 Pages

  25. IR02-TR

    1 Pages

  26. DR01

    2 Pages

  27. SR11-TR

    1 Pages

  28. NF02

    1 Pages

  29. HFP01

    1 Pages