Dry cleaning set 36kV
34Pages

{{requestButtons}}

Catalog excerpts

Dry cleaning set 36kV - 1

TECHNICAL SHEET ELBOW 90° PRODUCER: „HUBIX" CHARACTERISTICS Made of white PVC. Polyamide threaded end for tube extensions, nozzles and brushes connection. Weight: 105g APPLICATION Live working up to 36kV a.c. The elbows are the part of the cleaning set. They are used to dry cleaning method of the electrical devices. STORAGE AND MAINTENANCE The elbows should be properly stored to minimize the risk of damage due to storage or transportation. The elbows should be stored generally separated from other equipment to avoid mechanical damage. The elbows should be prevented from excessive heat and sun light. The elbows should be cleaning after each use. Dirty elbows should be cleaned by wiping the exterior surface of a dry cloth. With strong dirty exterior surfaces clean with a cloth dampened with a soft detergent and dry thoroughly. It is recommended to wipe the outer! elbows surface after drying, silicone tissue (supplied with the set). CHECK AND PERIODIC INSPECTION Before use, each part of equipment should be visually inspected by the user. Periodic inspection carried out in accordance with instructions for use. Periodic inspection includes a visual inspection and test of protection against bridging. The visual inspection includes checking: the lack of visible damage the surface of the elbows; the clarity and completeness of the labeling; the validity of the periodic inspection;

Open the catalog to page 1
Dry cleaning set 36kV - 2

Protection against bridging test consists of checking element in the measurement system of the test voltage of 1.2 Un (maximum rated voltage pieces of equipment). The test is passed when no spark-over or electric discharges are observed. Items of equipment damaged, badly worn or soiled not be used in the live working. If moisture should be thoroughly dried before use. For check and periodic inspection to be carried out in according to table.

Open the catalog to page 2
Dry cleaning set 36kV - 3

TECHNICAL SHEET MOVABLE ELBOW 90° PRODUCER: „HUBIX" CHARACTERISTICS Made of white PVC. Polyamide threaded end for tube extensions, nozzles and brushes connection. Weight: 190g APPLICATION Live working up to 36kV a.c. The elbows are the part of the cleaning set. They are used to dry cleaning method of the electrical devices. STORAGE AND MAINTENANCE The elbows should be properly stored to minimize the risk of damage due to storage or transportation. The elbows should be stored generally separated from other equipment to avoid mechanical damage. The elbows should be prevented from excessive...

Open the catalog to page 3
Dry cleaning set 36kV - 4

Protection against bridging test consists of checking element in the measurement system of the test voltage of 1.2 Un (maximum rated voltage pieces of equipment). The test is passed when no spark-over or electric discharges are observed. Items of equipment damaged, badly worn or soiled not be used in the live working. If moisture should be thoroughly dried before use. For check and periodic inspection to be carried out in according to table.

Open the catalog to page 4
Dry cleaning set 36kV - 5

TECHNICAL SHEET ELBOW 135° PRODUCER: „HUBIX" CHARACTERISTICS Made of white PVC. Polyamide threaded end for tube extensions, nozzles and brushes connection. Weight: 100g APPLICATION Live working up to 36kV a.c. The elbows are the part of the cleaning set. They are used to dry cleaning method of the electrical devices. STORAGE AND MAINTENANCE The elbows should be properly stored to minimize the risk of damage due to storage or transportation. The elbows should be stored generally separated from other equipment to avoid mechanical damage. The elbows should be prevented from excessive heat and...

Open the catalog to page 5
Dry cleaning set 36kV - 6

Protection against bridging test consists of checking element in the measurement system of the test voltage of 1.2 Un (maximum rated voltage pieces of equipment). The test is passed when no spark-over or electric discharges are observed. Items of equipment damaged, badly worn or soiled not be used in the live working. If moisture should be thoroughly dried before use. For check and periodic inspection to be carried out in according to table.

Open the catalog to page 6
Dry cleaning set 36kV - 7

TECHNICAL SHEETCIRCULAR BRUSH 9.2013 PRODUCER: „HUBIX” length CHARACTERISTICS Made of polyamide and natural brush. Polyamide threaded end for suction tube, tube extensions and elbows connection. Live working up to 36kV a.c. The brushes are the part of the cleaning set. They are used to dry cleaning method of the electrical devices. The brushes should be properly stored to minimize the risk of damage due to storage or transportation. The brushes should be stored generally separated from other equipment to avoid mechanical damage. The brushes should be prevented from excessive heat and sun...

Open the catalog to page 7
Dry cleaning set 36kV - 8

Protection against bridging test consists of checking element in the measurement system of the test voltage of 1.2 Un (maximum rated voltage pieces of equipment). The test is passed when no spark-over or electric discharges are observed. Items of equipment damaged, badly worn or soiled not be used in the live working. If moisture should be thoroughly dried before use. For check and periodic inspection to be carried out in according to table.

Open the catalog to page 8
Dry cleaning set 36kV - 9

CHARACTERISTICS Made of polyamide and natural brush. Polyamide threaded end for suction tube, tube extensions and elbows connection. Live working up to 36kV a.c. The brushes are the part of the cleaning set. They are used to dry cleaning method of the electrical devices. The brushes should be properly stored to minimize the risk of damage due to storage or transportation. The brushes should be stored generally separated from other equipment to avoid mechanical damage. The brushes should be prevented from excessive heat and sun light. The brushes should be cleaning after each use. Use a dry...

Open the catalog to page 9
Dry cleaning set 36kV - 10

Protection against bridging test consists of checking element in the measurement system of the test voltage of 1.2 Un (maximum rated voltage pieces of equipment). The test is passed when no spark-over or electric discharges are observed. Items of equipment damaged, badly worn or soiled not be used in the live working. If moisture should be thoroughly dried before use. For check and periodic inspection to be carried out in according to table.

Open the catalog to page 10

All Hubix Sp. z o.o. catalogs and technical brochures

  1. Equipment 1kV

    102 Pages

  2. Tools 1kV

    128 Pages

  3. HT

    2 Pages

  4. HS-2

    2 Pages

  5. HN10N

    2 Pages

  6. HN8N

    2 Pages

  7. HSZ

    2 Pages

  8. Hack-saw

    2 Pages

  9. 11923678

    2 Pages

  10. 11923671

    2 Pages

  11. HS-7

    2 Pages

  12. HS1

    2 Pages

  13. 11923694

    2 Pages

  14. 11923683

    2 Pages

  15. 11923670

    2 Pages

  16. 11923586

    2 Pages

  17. 11923708/

    2 Pages

  18. 11923687

    2 Pages

  19. 11923680

    2 Pages

  20. 11923923

    1 Pages

  21. 11923948

    1 Pages

  22. 11923949

    1 Pages

  23. 11923922

    1 Pages

  24. 11923951

    1 Pages

  25. Equipment

    1 Pages

  26. Hand

    1 Pages

  27. Hand tools

    1 Pages

Archived catalogs