One source from start to finish

Open the catalog to page 2
RADOX® cables and system solutions - 3

Innovation to achieve the goal The HUBER+SUHNER group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Our main markets are communication, transport and industry. Under one roof, we combine technological capabilities in the three core fields of radio frequency, fiber optics and low frequency. Increasing engine efficiency, lower power consumption and smaller space restrictions gave rise to higher temperature in the engine compartment. Temperatures of -70 to +200 °C (3000 h) are commonplace. The wiring is exposed to various fluids,...

Open the catalog to page 3
RADOX® cables and system solutions - 5

Automotive wires and cables 7 Automotive cable systems 43 Technical and delivery information 51

Open the catalog to page 5
RADOX® cables and system solutions - 6

HUBER+SUHNER Automotive products

Open the catalog to page 6
RADOX® cables and system solutions - 7

Low voltage cable for road vehicles, class D and F according to ISO 6722 and ISO 19642, temperature rating -40 to +150 °C/200 °C A growing demand of sensors, higher operating temperatures and restricted space are typical in today's motor compartments. These cables have been developed with these specific requirements in mind. These cables are class D temperature range cables with reduced outer diameter. They have superb resistance to motor oils, fluids and hydrolysis. Thanks to their electron beam cross-linked RADOX insulation, these cables have excellent resistance to extremes of...

Open the catalog to page 7
RADOX® cables and system solutions - 8

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 0.35 to 6 mm2 60/1500 V DC -55 to +150 °C (3000 h) 3 x cable dia. Composition of cable 1. Conductor stranded tinned or bare copper 2. Insulation RADOX 155S, extruded irradiation cross-linked polyolefin, various colours Characteristics and specialities • High and l ow temperature resistance • Ozone and weathering resistance • Resistant to pressure at high temperature • Resistant to motor oils, fuels and hydrolysis • Flame retardant • High ab rasion resistance • Easy to strip and process Application Low...

Open the catalog to page 8
RADOX® cables and system solutions - 9

Extract from our delivery programme Dimensions according to ISO 6722-1/ISO 19642, structure A HUBER+SUHNER Automotive products 9

Open the catalog to page 9
RADOX® cables and system solutions - 10

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 0.14 to 1 mm2 60 V DC -55 to +150 °C (3000 h) 3 x cable dia. Composition of cable 1. Conductor stranded, tin plated 2. Insulation RADOX 155S, extruded irradiation cross-linked polyolefin, various colours Characteristics and specialities • High and l ow temperature resistance • Ozone and weathering resistance • Resistant to pressure at high temperature • Resistant to motor oils, fuels and hydrolysis • Flame retardant • High ab rasion resistance • Easy to strip and process Application Low voltage cable...

Open the catalog to page 10
RADOX® cables and system solutions - 11

Extract from our delivery programme HUBER+SUHNER Automotive products 11

Open the catalog to page 11
RADOX® cables and system solutions - 12

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 0.14 to 6 mm2 60/600 V DC -55 to +200 °C (3000 h) 3 x cable dia. Composition of cable 1. Conductor stranded bare copper 2. Insulation ETFE, extruded fluoropolymer, various colours Characteristics and specialities • High and 1 ow temperature resistance • Ozone and weathering resistance • Resistant to pressure at high temperature • Resistant to hot motor oils, fuels and hydrolysis • Flame retardant • High ab rasion resistance • Easy to strip and process Application Low voltage cable for use in road...

Open the catalog to page 12
RADOX® cables and system solutions - 13

Extract from our delivery programme Dimensions according to ISO 6722-1/ISO 19642 HUBER+SUHNER Automotive products 13

Open the catalog to page 13
RADOX® cables and system solutions - 14

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 0.35 10 mm2 60/1500 V DC -55 to +150 °C (3000 h) 3 x cable dia. Composition of cable 1. Conductor stranded tinned or bare copper, special coating 2. Insulation RADOX 155S, extruded irradiation cross-linked polyolefin (FLR91X), various colours Characteristics and specialities • Barrier sealed, avoids penetration of fluids along conductor (fluids such as water and AdBlue) • High and l ow temperature resistance • Ozone and weathering resistance • Resistant to pressure at high temperature • Resistant to...

Open the catalog to page 14
RADOX® cables and system solutions - 15

Extract from our delivery programme Dimensions according to ISO 6722-1/ISO 19642 structure A HUBER+SUHNER Automotive products 15

Open the catalog to page 15
RADOX® cables and system solutions - 16

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 0.35 to 6 mm2 60/1500 V DC -55 to +150 °C (3000 h) 3 x cable dia. Composition of cable 1. Conductor stranded tinned or bare copper, special coating 2. Insulation RADOX 155S, extruded irradiation cross-linked polyolfin 3. Insulation extruded irradiation crosslinked fluoropolymer (PVDF-X) for hot oil applications Characteristics and specialities • Barrier sealed, avoids penetration of fluids along conductor (fluids such as water, AdBlue and hot oils) • High and l ow temperature resistance • Ozone and...

Open the catalog to page 16
RADOX® cables and system solutions - 17

Extract from our delivery programme Dimensions according to ISO 6722/ISO 19642 structure B HUBER+SUHNER Automotive products 17

Open the catalog to page 17
RADOX® cables and system solutions - 18

HUBER+SUHNER Automotive products

Open the catalog to page 18
RADOX® cables and system solutions - 19

RADOX® battery cables – thin-wall, flexible Power cables for road vehicles, class D according to ISO 6722, operating temperature −40 to +150 °C RADOX battery cables are high temperature resistant products with a reduced outer diameter. The cable is highly resistant to temperature, ozone, weathering, hydrolysis and has excellent resistance to battery acid and cooling agents. It is also resistant against oils, fuels and other fluids used inside and outside of the motor compartment. Thanks to its electron beam cross-linked RADOX insulation, the cable has, despite the reduced outer diameter,...

Open the catalog to page 19
RADOX® cables and system solutions - 20

Number of conductors Cross section Voltage rating Temperature range Min. bending radius 1 10 to 150 mm2 1000 V AC/1500 V DC -55 to +150 °C (3000 h) 3 x cable dia. 1. Conductor stranded bare copper 2. Plastic tape optional 3. Insulation RADOX 155, extruded irradiation cross-linked polyolefi various colours Characteristics and specialities • Excellent high and low temperature resistance • Ozone, weathering and hydrolysis resistance • Outstanding resistance against battery acids, humidity, petrol, brake fluids, engine coolant, window washer, fluids, diesel and various oils • Flame retardant •...

Open the catalog to page 20

All HUBER+SUHNER catalogs and technical brochures

  1. WHITE PAPER

    7 Pages

  2. RF cables

    72 Pages

  3. Antennas

    105 Pages

  4. FO components

    11 Pages

  5. RF components

    44 Pages

  6. Space

    140 Pages

  7. Aviation

    28 Pages

  8. Defense

    146 Pages

  9. FO LISA

    202 Pages

  10. Wires & Cables

    156 Pages

  11. Milcat 7

    2 Pages

  12. VITA 67

    2 Pages

  13. Microbend L

    2 Pages

  14. FO Cables

    160 Pages

  15. Aviation

    28 Pages

  16. RF Connectors

    478 Pages

  17. RF - Guide

    159 Pages

  18. Medical

    20 Pages

  19. Rail CBTC

    12 Pages