Harsh environment Connectors and assemblies
72Pages

{{requestButtons}}

Catalog excerpts

Harsh environment Connectors and assemblies - 1

Harsh environment Connectors and assemblies Edition 2019/01

Open the catalog to page 1
Harsh environment Connectors and assemblies - 2

Fitting all environmental conditions

Open the catalog to page 2
Harsh environment Connectors and assemblies - 3

Market segments Overview connectors for harsh environment 6 Overview fiber optic cables for harsh environment assemblies 8 Hermaphroditic expanded beam connector EBC 62 Cleaning of fiber optic connectors 64 Find out more about our products 70 Your partner for system solutions The HUBER+SUHNER Group is a leading global supplier of components and systems for electrical and optical connectivity. Our customers in communications, industrial and transportation markets appreciate that we are specialists with detailed knowledge of practical applications. We offer technical expertise in radio...

Open the catalog to page 3
Harsh environment Connectors and assemblies - 4

Market segments Railway HUBER+SUHNER is the leading supplier of modern communication infrastructures for trainborne, train-to-ground and ground networks. • Copper cable technology • Radio frequency antennas and components • Fiber optic cabling solutions • Engineering services Defense High quality connectivity in • Airborne defence systems Avionics, airborne radar and electronic warfare • Land-based defence systems Radar and electronic warfare, simulation and training systems, air traffic control radar, ILS • Naval defence systems Sonar, radar and electronic warfare, underwater warfare...

Open the catalog to page 4
Harsh environment Connectors and assemblies - 5

Wind/power energy HUBER+SUHNER supplies specific connectivity solutions for applications in • Solar technology • Wind turbines and wind parks • Conventional power generators Ship building HUBER+SUHNER offers an extensive range of components and systems adapted to the requirements of the shipbuilding industry. These include solutions for: • Cruise liners and naval vessels • Ferries and yachts • Port installations Communication equipment HUBER+SUHNER products are used globally in • Mobile communication systems such as 2G, 2.5G, 3G, LTE (Long-Term Evolution), GSM-R, PMR networks • Wireless...

Open the catalog to page 5
Harsh environment Connectors and assemblies - 6

Overview connectors for harsh environment Technical data full ceramic 1.25 mm ferrule and sleeve full ceramic 1.25 mm ferrule and sleeve full ceramic 1.25 mm ferrule and sleeve Protection class Fiber types Mating durability Mechanical performance tensile load 450 N plug ≤ 30 N socket tensile load 500 N plug ≤ 30 N socket tensile load 800 N plug ≤ 30 N socket tensile load 800 N plug ≤ 30 N socket depending on cable type with repeated cleaning 3) further cable types are available 1) HUBER+SUHNER FO Harsh environment – co

Open the catalog to page 6
Harsh environment Connectors and assemblies - 7

HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 7
Harsh environment Connectors and assemblies - 8

Cable type Weight kg/km Overview fiber optic cables for harsh environment assemblies Mobile field cables Rugged minicord breakout cables Simplex cables with tight tube Jellyfree – dry block 12-.../H(ZNG)H-G70-UR glass-armoured multi-fiber loose tube cables 7.0 mm OptiPack cable Glass-armoured riser cables with 2 tubes Glass-armoured riser cables with 4 fibers Rolling stock fiber optic cable RADOX® with 2 fibers HUBER+SUHNER FO Harsh environment – connectors and assembli

Open the catalog to page 8
Harsh environment Connectors and assemblies - 9

HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 9
Harsh environment Connectors and assemblies - 10

Harsh environment connectors according to the HE catalogue. Standard connectors according to the catalogue. Examples PT01 _LCUS_0000_SM09E_02.0_S0 Pigtail one fiber, LC UPC simplex connector on the left, without connector on the right, SM G.652.D, 0.9 mm fiber, 2 m length, SM standard performance PCDS_LCMD_LCMD_O420E_05.5_LL Patch cord duplex zip cord (fig. 8), LC MM standard duplex left and right, OM4 duplex zip cord 2.0 mm, 5.5 m length, MM low loss performance 10 HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 10
Harsh environment Connectors and assemblies - 12

Q-ODC-2 assemblies Q-ODC-2 outdoor connector Features • 2 fibers, single-mode or multi-mode • Compact design with 2 x 1.25 mm ferrules • Built-in socket with square flange • Extension connector for cable chaining • Robust push-pull coupling mechanism - two clearly defined mating states • Highest outdoor installation safety • Waterproof, dust proof and corrosion resistant • Waterproof protection caps available • EMI protected • RoHs compliant • Fulfills performance standard IEC 61753-1 cat. E 11 depending on cable type 2) with repeated cleaning Optical performance Mating/un-mating sequences...

Open the catalog to page 12
Harsh environment Connectors and assemblies - 13

Overview of Q-ODC connector types Q-ODC - push-pull connector for modular cell site installations Q-ODC is used by a growing number of operators who build a modular and flexible cell site cable infrastructure. The push-pull connectors allows for quick and reliable cable connections, e.g. for top-mast boxes or jumpers. Additionally, the interface is designed that it is either mated or unmated - nothing in between. This makes each installation of cell site infrastructure safe. HUBER+SUHNER FO Harsh environment - connectors and assemblies 13

Open the catalog to page 13
Harsh environment Connectors and assemblies - 14

Type QOE1, QOE2, QOE3, QOE4: Q-ODC extension connector Type QOS1, QOS2, QOS3, QOS4: Q-ODC socket – square hole pattern hole pattern HUBER+SUHNER FO Harsh environment – connectors and assemblie

Open the catalog to page 14
Harsh environment Connectors and assemblies - 15

Connector left Q-ODC-2 plug Type QOP2 Connector right Q-ODC-2 plug Type QOP2 HUBER+SUHNER FO Harsh environment - connectors and assemblies 15

Open the catalog to page 15
Harsh environment Connectors and assemblies - 16

Connector left Q-ODC-2 plug Connector right LC connector 16 HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 16
Harsh environment Connectors and assemblies - 17

Connector left Q-ODC-2 plug Connector right LC connector HUBER+SUHNER FO Harsh environment - connectors and assemblies 17

Open the catalog to page 17
Harsh environment Connectors and assemblies - 18

Connector left Q-ODC-2 plug Connector right SC connector 18 HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 18
Harsh environment Connectors and assemblies - 19

Connector left Q-ODC-2 socket Dust cap snap-on with chain Connector right LC connector HUBER+SUHNER FO Harsh environment - connectors and assemblies 19

Open the catalog to page 19
Harsh environment Connectors and assemblies - 20

20 HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 20
Harsh environment Connectors and assemblies - 21

Connector left Q-ODC-2 socket ket, Dust cap snap-on with chain Connector right SC connector HUBER+SUHNER FO Harsh environment - connectors and assemblies 21

Open the catalog to page 21
Harsh environment Connectors and assemblies - 22

22 HUBER+SUHNER FO Harsh environment - connectors and assemblies

Open the catalog to page 22
Harsh environment Connectors and assemblies - 24

Features • Up to 24 fibers, singlemode or multimode • Compact design with MT ferrules • Built-in socket with square flange/hexagonal flange • Extension connector for cable chaining • Robust push-pull coupling mechanism - two clearly defined mating states • Highest outdoor installation safety • Waterproof, dust proof and corrosion resistant • Waterproof protection caps available • RoHs compliant 11 depending on cable type 2) with repeated cleaning Optical performance - MTP performance by fiber type/grade Fiber type/grade Mating/un-mating sequences Mated - connector snaps in and is fully...

Open the catalog to page 24

All HUBER+SUHNER catalogs and technical brochures

  1. Antennas

    109 Pages

  2. WHITE PAPER

    7 Pages

  3. RF cables

    72 Pages

  4. Antennas

    105 Pages

  5. FO components

    11 Pages

  6. RF components

    44 Pages

  7. Space

    140 Pages

  8. Aviation

    28 Pages

  9. Defense

    146 Pages

  10. FO LISA

    202 Pages

  11. Wires & Cables

    156 Pages

  12. Milcat 7

    2 Pages

  13. VITA 67

    2 Pages

  14. Microbend L

    2 Pages

  15. FO Cables

    160 Pages

  16. Aviation

    28 Pages

  17. RF Connectors

    478 Pages

  18. RF - Guide

    159 Pages

  19. Medical

    20 Pages

  20. Rail CBTC

    12 Pages