Single-Phase Central Lighting Inverters Catalog Number Comments Application Designed for indoor installation in commercial or industrial applications. Operation When normal utility-supplied power is present, the LSN model central lighting inverter provides load-side line conditioning with "brownout" protection, and charges the system batteries when required. When utility-supplied power is interrupted, or the voltage varies from predetermined limits, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time). A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards. Construction The LSN cabinet is constructed of steel, finished with a light gray paint and features locking cabinetry and password-protected user interface for security. Louvers at front and top of cabinet allow venting. ORDERING GUIDE Series LSN Central Lighting Inverter S = 10-year Sealed Lead-Calcium G = 20-year Sealed Lead-Calcium N = 25-year Nickel- Cadmium Output Circuit Breaker Ampere Rating (7) Output Circuit Breaker Type Blank = Normally On N = Normally Off Requires a provided external transformer for 208VAC or 240VAC input. 277 and 347VAC input only. Other voltages available. Consult factory. External transformer may be provided. Loading may not exceed 50% of the system’s total rating on any 120VAC leg. Normally On circuit breakers: a maximum of 14 monitored, single pole positions or 20 unmonitored, single pole positions may be specified. Normally Off circuit breakers: a maximum of 8 single pole positions (monitored or unmonitored) may be specified. Normally Off circuit breakers: a maximum rating of 20 amps. The EPO option requires the SMT option. Specify runtime in minutes when ordering. Example: AR120. Available with 1.0, 2.0, 2.7, 3.7, 5.5, and 6.6KVA Series with S batteries only. Available on 1.0 KVA - 4.8KVA Series. Available on 5.5 KVA - 17.5KVA Series. Not available with 120V input on 6.6KVA and above. Not available with 208V input on 12.5 KVA and above. Not available with 240V input on 15.0 KVA and above. Supplied in a wall mounted, NEMA 1 type enclosure. Cannot be used in systems with more than one single-pole output circuit breaker, on systems with different input and output voltages. See System Configuration for 90-Minute Run Time. Type S Battery only; See system configuration for 90-minute run time. Not available on 8.3KVA - 17.5KVA Series. Output Circuit Breaker Supervision Blank = Monitored U = Unmonitored Output Circuit Breaker Voltage Rating A = 120 VAC B = 240 VAC C = 277 VAC D = 208 VAC Output Circuit Breaker Quantity (6) 01 to 20 Other Options & Accessories Options EML = Email Device RSP = Remote Status Panel SMT = System Monitoring Terminal EPO = Emergency Power Off Terminal (8) AR = Alternate Runtime (9) SBC = Short Battery Cabinet (10) IBS = Internal Maintenance Bypass Switch (Make Before Break) C10 = 10 Amp Charger Upgrade (11) C20 = 20 Amp Charger Upgrade (12) CL60 = Cabinet Locks S = Seismic Qualified(15) Accessories MBB = External Maintenance Bypass Switch (13) (Make Before Break) BBM = External Maintenance Bypass Switch (13) (Break Before Make) DSFK__ = Seismic Kit (14)

Open the catalog to page 1
LSN Inverter specification sheet - 2

Single-Phase Central Lighting Inverters OPTIONS AND ACCESSORIES Suffix Email Device A device that automatically notifies the user of system test results and alarm conditions. The Email Device sends detailed notifications to up to six pre-programmed email addresses. Requires customer supplied CAT5 cable connected to user network. Remote Status Panel Provides remote annunciation for the LSN inverter to indicate inverter and alarm status. Owner-installed option. Must be installed within 1,000 ft. of the LSN inverter. Seven-conductor-minimum, 22AWG wire for connection from options board to...

Open the catalog to page 2
LSN Inverter specification sheet - 3

Single-Phase Central Lighting Inverters SPECIFICATIONS KVA/KW Rating Power Factor Range Input/Output Voltage Combinations Available – Single Phase AC Input Circuit Breaker Rating — 120/277V Output Voltage and Maximum Output Current in Amperes Standard Charger Size Heat Output (BTU/Hr) On systems with 120/240VAC output, loading may not exceed 50% of the system’s total KVA rating on any 120V leg. Loading beyond 50% on any 120V leg will cause an unsafe condition and transformer failure will occur. Call our Service Line at 800-848-6439 for alternate load connection configurations. (2) An...

Open the catalog to page 3
LSN Inverter specification sheet - 4

Single-Phase Central Lighting Inverters System Configurations for 90-Minute Runtime Type S Battery Maintenance-Free Sealed Lead-Calcium — 10-Year Design Life Expectancy at 25°C (77°F) ­ Standard LSN system battery; lead calcium grid alloy with electrolyte trapped in absorbent glass mat (AGM) separators. Completely sealed and requires no addition of water over its life expectancy. Polypropylene case and cover includes UL recognized low pressure safety release vents. No gassing will occur in normal use. System Capacity System Configuration Type G Battery Maintenance-Free Sealed Lead-Calcium —...

Open the catalog to page 4