Pressure sensor 528 -1 ... 0 – 60 bar
9Pages

{{requestButtons}}

Catalog excerpts

Pressure sensor 528 -1 ... 0 – 60 bar - 1

Pressure transmitter Relative and absolute pressure transmitter Type 528 The compact type 528 pressure transmitter is based upon the well proven ceramic technology developed by Huba Control over 20 years ago. These transmitters are suitable for applications across a broad spectrum of industries. + Compact, rugged construction + Negligible temperature influence on accuracy + Large selection of connections available + Saving time by quick cable mounting by the customer with swift connector Huba Control Type 528 | Technical data subject to change | Edition 09/2020

Open the catalog to page 1
Pressure sensor 528 -1 ... 0 – 60 bar - 2

Technical overview Pressure range Relative Absolute Operating conditions Medium FPM -15 ... +125 ºC EPDM -40 ... +125 ºC Medium NBR -20 ... +100 ºC Temperature MVQ -40 ... +125 ºC FPM -40 ... +125 ºC Ambient -30 ... +85 ºC Storage -50 ... +100 ºC < 4 bar 3.0 x fs Tolerable overload / Rupture pressure > 4 bar 2.5 x fs Materials Cover Plug accommodation Pressure connection Materials in contact with medium Sensor Sealing material Stainless steel 1.4404 / AISI 316L Polyarylamide 50% GF UL 94 V-0 Stainless steel 1.4404 / AISI 316L PVDF Ceramic Al2O3 (96%) FPM, EPDM, NBR, MVQ Electrical overview...

Open the catalog to page 2
Pressure sensor 528 -1 ... 0 – 60 bar - 3

Accuracy Parameter Test conditions: Characteristic line 1) Resolution max. Thermal characteristic 2) Long term stability acc. IEC EN 60770-1 max. Order code selection in bar Pressure range (relative) 3) 0 ... 1 bar 8 1 1 0 ... 1.6 bar 8 1 2 0 ... 2.5 bar 8 1 4 Pressure range 0 ... 4 bar 8 1 5 3) (absolute) 0 ... 6 bar 8 1 7 0 ... 10 bar 8 3 0 0 ... 16 bar 8 3 1 ( -15 ... +120 ºC) 0 FPM Fluoro elastomer EPDM Ethylene propylene ( -30 ... +120 ºC) 1 Sealing material NBR Butadiene Acylonitrile 2 ( -30 ... +120 ºC) 3 MVQ Silicone polymer FPM Fluoro elastomer ( -30 ... +120 ºC) 5 standard 0...

Open the catalog to page 3
Pressure sensor 528 -1 ... 0 – 60 bar - 4

Order code selection in psi Pressure range (relative) 1) 0 ... 15 psi 8 B 1 0 ... 20 psi 8 B 2 0 ... 30 psi 8 B 4 Pressure range 0 ... 60 psi 8 B 5 (absolute) 1) 0 ... 100 psi 8 B 7 0 ... 150 psi 8 C 0 0 ... 200 psi 8 C 1 FPM Fluoro elastomer ( -15 ... +120 ºC) 0 EPDM Ethylene propylene ( -30 ... +120 ºC) 1 Sealing material NBR Butadiene Acylonitrile 2 MVQ Silicone polymer ( -30 ... +120 ºC) 3 FPM Fluoro elastomer ( -30 ... +120 ºC) 5 standard 0 Application for oxygen applications 0 1 1 1 with drinking water approval NSF 61 0 4 1 1 0 ... 5 V 7 ... 33 VDC 1 1 ... 6 V 8 ... 33 VDC 6 12 ... 33...

Open the catalog to page 4
Pressure sensor 528 -1 ... 0 – 60 bar - 5

Order code selection in MPa Pressure range (relative) 1) 0 ... 0.1 MPa 8 G 1 0 ... 0.16 MPa 8 G 2 0 ... 0.25 MPa 8 G 4 Pressure range 0 ... 0.4 MPa 8 G 5 (absolute) 1) 0 ... 0.6 MPa 8 G 7 0 ... 1 MPa 8 H 0 0 ... 1.6 MPa 8 H 1 FPM Fluoro elastomer ( -15 ... +120 ºC) 0 EPDM Ethylene propylene ( -30 ... +120 ºC) 1 Sealing material NBR Butadiene Acylonitrile 2 MVQ Silicone polymer ( -30 ... +120 ºC) 3 FPM Fluoro elastomer ( -30 ... +120 ºC) 5 standard 0 Application for oxygen applications 0 1 1 1 with drinking water approval NSF 61 0 4 1 1 0 ... 5 V 7 ... 33 VDC 1 1 ... 6 V 8 ... 33 VDC 6 12...

Open the catalog to page 5
Pressure sensor 528 -1 ... 0 – 60 bar - 6

Accessories (supplied loose) Order number Swift connector Female connector DIN EN 175301-803-A with seal Female connector DIN EN 175301-803-C with seal Corner-wire box for connector M12x1 Corner-wire box for connector M12x1 with cable 2.0 m Straight-wire box for connector M12x1 Straight-wire box for connector M12x1 with cable 2.0 m Mounting bracket with screw Heat sink with outside thread G ½ sealed at front - inside thread G ½ Heat sink with outside thread G ½ sealed at front - inside thread G ¼ Heat sink with outside thread G ¼ sealed at front - inside thread G ¼ Calibration certificate...

Open the catalog to page 6
Pressure sensor 528 -1 ... 0 – 60 bar - 7

Swift connector Metri Pack 150 P2S Series Huba Control Type 528 | Technical data subject to change | Edition 09/2020

Open the catalog to page 7
Pressure sensor 528 -1 ... 0 – 60 bar - 8

Electrical connections 2 wire Connector DIN EN 175301-803-A or C Swift connector Metri Pack 150 P2S Series blue green Swift connector Metri Pack 150 P2S Series Device design with explosion protection: 4 ... 20 mA The grounding connection is conductively connected to the transmitter housing. Connector DIN EN 175301-803-A Device design with explosion protection: ratiom. 10 ... 90% The electronic GND is connected with a 1MΩ resistor to the transmitter housing. Not connected with transmitter housing Huba Control Type 528 | Technical data subject to change | Edition 09/2020

Open the catalog to page 8
Pressure sensor 528 -1 ... 0 – 60 bar - 9

Huba Control AG Headquarters Schweiz Industriestrasse 17 CH-5436 Würenlos Telefon Niederlassung Deutschland Vestiging Nederland Succursale France Branch Office United Kingdom Unit 13 Berkshire House, County Park Technopôle Forbach-Sud Business Centre, Shrivenham Road

Open the catalog to page 9