Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 1

Relative and absolute pressure transmitter Type 528 IO-Link The pressure transmitter Type 528 for industrial applications impresses with its compact and robust design as well as high accuracy and reliability. The hermetically welded stainless steel sensor offers very high overpressure safety and is suitable for use in gases, liquids and all common refrigerants including ammonia. Huba Control offers with the Type 528 a universally applicable pressure transmitter with IO-Link communication technology. IO-Link is a standardized, digital point-to-point connection that allows the user to easily wire the unit and access a wide range of specific device and process data. IO-Link offers numerous possibilities for device diagnostics, allowing the status of the pressure transmitter to be continuously monitored. This makes the 528 IO-Link the ideal pressure transmitter for your Industry 4.0 application. + Compact, rugged construction + Communication via IO-Link 1.1 (Smart Sensor Profile ED2) + Sensor diagnosis function + High flexibility of process connections Huba Control Type 526 IO-Link | Technical data subject to change | Edition 09/2020

Open the catalog to page 1
Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 2

Technical overview Pressure range Relative Absolute Operating conditions Medium FPM EPDM Medium NBR Temperature MVQ FPM Ambient Storage < 4 bar 3.0 x fs Tolerable overload / Rupture pressure > 4 bar 2.5 x fs Materials Cover Plug accommodation Pressure connection Materials in contact with medium Sensor Sealing material Stainless steel 1.4404 / AISI 316L Polyarylamide 50% GF UL 94 V-0 Stainless steel 1.4404 / AISI 316L PVDF Ceramic Al2O3 (96%) FPM, EPDM, NBR, MVQ Electrical overview Output Power supply Permanent current load Current consumption 4 wire IO-Link 18 ... 33 VDC 100 mA per...

Open the catalog to page 2
Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 3

Accuracy Parameter Test conditions: Characteristic line 1) Resolution max. Thermal characteristic 2) Long term stability acc. IEC EN 60770-1 max. Order code selection table in bar Pressure range (relative) 3) 0 ... 1 bar 8 1 1 0 ... 1.6 bar 8 1 2 0 ... 2.5 bar 8 1 4 Pressure range 0 ... 4 bar 8 1 5 (absolute) 3) 0 ... 6 bar 8 1 7 0 ... 10 bar 8 3 0 0 ... 16 bar 8 3 1 (-15 ... +100 ºC) 0 FPM Fluoro elastomer EPDM Ethylene propylene 1 Sealing material NBR Butadiene Acylonitrile 2 MVQ Silicone polymer 3 (-30 ... +100 ºC) 5 FPM Fluoro elastomer Application standard 0 Output / power supply...

Open the catalog to page 3
Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 4

Accessories (supplied loose) Order number Corner-wire box for connector M12x1 with cable 2.0 m Straight-wire box for connector M12x1 with cable 2.0 m Mounting bracket with screw Heat sink with outside thread G ½ sealed at front - inside thread G ½ Heat sink with outside thread G ½ sealed at front - inside thread G ¼ Heat sink with outside thread G ¼ sealed at front - inside thread G ¼ Calibration certificate Mounting bracket with screw Heat sink Huba Control Type 528 IO-Link | Technical data subject to change | Edition 09/2

Open the catalog to page 4
Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 5

10 5 Code Nr.:Nm Code Nr.: A Electrical connections 4 wire Connector M12x1 Legend: L+ = power Supply + L- = power Supply C/Q = IO-Link/switching output 1 DI/DQ = switching output 2 Huba Control Type 526 IO-Link | Technical data subject to change | Edition 09/2020

Open the catalog to page 5
Pressure sensor 528 IO-Link -1 ... 0 - 60 bar - 6

Huba Control AG Headquarters Schweiz Industriestrasse 17 CH-5436 Würenlos Telefon Niederlassung Deutschland Vestiging Nederland Succursale France Branch Office United Kingdom Unit 13 Berkshire House, County Park Technopôle Forbach-Sud Business Centre, Shrivenham Road