Pressure measuring cell 509 0 ... 2.5 - 250 bar - 1

Huba Control FOR FINE PRESSURE AND FLOW MEASUREMENT OEM Relative pressure measuring cell 509 Pressure range 0 ... 2.5 - 250 bar Negligible temperature influence on accuracy No customer specific adjustment of zero point and temperature compensation necessary Easy mounting Overload secure up to rupture pressure Type 509 pressure measuring cells are based on ceramic technology developed by Huba Control, and used for the last 15 years in millions of applications. Due to the robust design of the ceramic cell there are no significant changes in the sensor characteristics when mounted by the customer.The pressure measuring cells are delivered either factory set or with TK zero point adjustment. You can choose between various versions including temperature measurement. Huba Control type 509 - Technical data subject to change - Edition 09/2013 1/5

Open the catalog to page 1
Pressure measuring cell 509 0 ... 2.5 - 250 bar - 2

Pressure range Relative 0 ... 2.5 - 250 bar Operating conditions Medium Temperature influences in range -30 ... +125 °C Overload / Rupt ure pressure 11 Humidity protection_ FPM spec. Storage in packaging Zero point Span < 4 bar > 6 bar Liquids and neutral gases_ Material in contact with the medium Sensor_Ceramic Al2O3 (96%) Sealing material_FPM, NBR, FPM spec. Electrical data Bridge impedance Power supply Insulation voltage ESD-handling Electromagnetic compatibility _10 kOhm ±20%_ _3 ... 30 VDC_ _2000 VDC_ _Necessary_ The product is designed exclusively forinstallation in equipment. The...

Open the catalog to page 2
Pressure measuring cell 509 0 ... 2.5 - 250 bar - 3

Accessories 3) Order number Back-up ring teflon_> 100 bar_114660 Screw insert for clamp screw_112187 Screw insert Clamp screw 1) Other pressure range on request 3) Accessories supplied loose Huba Control type 509 - Technical data subject to change - Edition 09/2013 3/5

Open the catalog to page 3
Pressure measuring cell 509 0 ... 2.5 - 250 bar - 4

Dimensions in mm / Elecrtical connections Flex connection Prevent repeated bending Flex connection Pin connection 5 Pins with temperature measuring Huba Control type 509 - Technical data subject to change - Edition 09/2013

Open the catalog to page 4
Pressure measuring cell 509 0 ... 2.5 - 250 bar - 5

Huba Control SA Succursale France Rue Lavoisier Technopole Forbach-Sud 57602 Forbach Cedex Telephone +33 (0) 387 847 300 Telecopieur +33 (0) 387 847 301 info.fr@hubacontrol.com Huba Control AG Branch Office United Kingdom Unit 13 Berkshire House County Park Business Centre Shrivenham Road Swindon Wiltshire SN1 2NR Phone +44 (0) 1993 776667 Fax +44 (0) 1993 776671 info.uk@hubacontrol.com 5/5 Huba Control type 509 - Technical data subject to change - Edition 09/2013