Overview: The Huba Control Type 200 is a flow sensor based on the Karman Vortex principle, designed for liquid media. It offers versions with or without temperature measurement and is characterized by its high accuracy, low cost, and resistance to debris and temperature variations.
Specifications:
  • Flow Range: 0.5 to 150 l/min
  • Nominal Diameters: DN 6, 8, 10, 15, 20, 25
  • Temperature Measurement: -40 to +125 ºC using PT1000 or NTC sensors
  • Accuracy: <1% fs for <50% fs and <2% for >50% fs
  • Response Time: Immediate with signal delay <100 ms
Operating Conditions:
  • Medium: Suitable for heating circuit water and drinking water
  • Temperature: Media up to +125 ºC, ambient -15 to +85 ºC
  • Pressure: Max 12 bar at +40 ºC, 6 bar at +100 ºC
Materials:
  • Sensor Paddle: ETFE
  • Case: PA6T/6I (40% GF)
  • Sealing Material: FPM, EPDM
Electrical Overview:
  • Power Supply: 5 VDC ±5%
  • Output: Frequency square pulse signal
  • Current Consumption: Standard <6 mA, enhanced EMC protection <10 mA
Approvals:
  • Drinking water approvals: KTW, W270, ACS, WRAS
  • Electromagnetic compatibility: EN 61326-2-3
Accessories: Various connection kits and adapters are available for different nominal diameters, including copper tubes and stainless steel adapters.
Installation Instructions: Ensure correct function by allowing only diameter changes from large to small and avoiding repeated elbows at the entry side.
Viscosity Influence: The document provides formulas to correct the influence of media with higher viscosity than water to maintain measuring accuracy.
See more

Catalog excerpts

OEM Flow sensor 200 0.5 ... 150 l/min-1

Vortex flow sensor OEM Flow sensor for liquid media Type 200 The flow sensor Type 200 is based on the Karman Vortex principle. You can choose between various versions. The Type 200 is available with or without temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy. + Low cost product with high levels of accuracy + Temperature non-sensitive measuring principle + Excellent media resistance (measuring element not in contact with the media) + Wide application temperature range + Marginal loss of pressure + Measuring element not sensitive to debris + Direct temperature measurement in the medium with PT1000 or NTC + Drinking water approval KTW, W270, ACS, WRAS Huba Control Type 200 | Technical data subject to change | Edition 09/2020

 Open the catalog to page 1
OEM Flow sensor 200 0.5 ... 150 l/min-2

Technical overview Flow measurement Measuring principle Vortex Measuring range Nominal diameters Accuracy at < 50% fs (water) Accuracy at > 50% fs (water) Immediately Signal delay Response time Therefore suitable for spigot use. Response time Temperature measurement (> DN 8) Measuring principle Resistance Measuring range @ T = 0 ºC PT1000 Accuracy Class B DIN EN 60751 @ T ≠ 0 ºC Measuring range @ T = +25 ºC NTC 10 kOhm @ 25 ºC NTC @ T < +25 ºC Accuracy β = 4050 @ T > +25 ºC Self-heating at temperature sensor Temperature influences Conduction resistance to connector Piezoelectric sensor element...

 Open the catalog to page 2
OEM Flow sensor 200 0.5 ... 150 l/min-3

Nominal diameters dependent variables Nominal diameters DN 6 Measuring range Flow rate Frequency range Characteristic line formula frequency output QV = Kf * ƒ + Q0 Formula quantity per pulse [litres/pulse] quantity QV * Kf = pulse 60 * (QV - Q0) Legend Volume flow rate [l/min] QV Axis intercept [l/min] Q0 Coefficient frequency output [(l/min) / ƒ] Kf ƒ Frequency [Hz] quantity litres Quantity per pulse pulse pulse (Influence of viscosity for media other than water - see page 8) incl. 3xDi inlet and outlet side 2) Pv in Pa; Q in l/min Huba Control Type 200 | Technical data subject to change |...

 Open the catalog to page 3
OEM Flow sensor 200 0.5 ... 150 l/min-4

Order code selection table Flow 9 Flow and temperature (PT1000) 8 1 Flow and temperature (NTC) 7 1 DN 6 0.5 ... 10 l/min. 9 0 6 1 DN 8 0.9 ... 15 l/min. 0 8 1 DN 10 1.8 ... 32 l/min. 1 0 Nominal diameters / DN 10 2.0 ... 40 l/min. 1 1 flow range DN 15 3.5 ... 50 l/min. 1 5 DN 20 5.0 ... 85 l/min. 2 0 DN 25 9.0 ... 150 l/min. 2 5 Frequency output, 0 ... 5 VDC (Square pulse signal) 5 VDC standard 9 0 Output / power supply Frequency output, 0 ... 5 VDC (Square pulse signal) 5 VDC enhanced EMC protection 1 3-pole connector RAST 2.5 9 0 2x3-pole connector RAST 2.5 7,8 1 1 3-pole connector RAST 2.5...

 Open the catalog to page 4
OEM Flow sensor 200 0.5 ... 150 l/min-5

Huba Control Type 200 | Technical data subject to change | Edition 09/20

 Open the catalog to page 5
OEM Flow sensor 200 0.5 ... 150 l/min-6

Admissible locking torque inside thread Geometry of customers connection tube DN 8, 10, 15, 20 o-ring Huba Control Type 200 | Technic

 Open the catalog to page 6
OEM Flow sensor 200 0.5 ... 150 l/min-7

Tube mounting instructions Consider the following to ensure the correct function of the sensor. • Only diameter changes from large to small are allowed. • Avoid repeated elbows in the same level at entryside minimum 5xDN for alternative elbows minimum 0.5xDN for recommended 90º elbow with min. R 1.8xDN Electrical connections RAST 2.5 without temperature output Connector M12x1 without temperature output Connector 2x3-poles with temperature output Ω Connector M12x1 with temperature output Pin Colour 1 brown 3 blue 1 4 black 1 brown 2 white 3 blue 2 4 black 5 gray Huba Control Type 200 | Technical...

 Open the catalog to page 7
OEM Flow sensor 200 0.5 ... 150 l/min-8

With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity > 1.8 cST) in order to reach 0 a measuring accuracy of 3% fs in the range of 1.8 - 4 cST and of 4% in the range of 1 - 14 cSt3(υ = 4 4 2 viscosity 6 cSt). 8 in 7 5 9 10 11 12 13 14 Viskosität in cSt Minimal detektierbarer Durchfluss Definition of viscosity of glycol-water-compound Kinematische Viskosität Propylenglykol‐Wasser Kinematic viscosity propylene glycol water Minimaler Durchfluss in l/min 25 Kinematische Viskosität Ethylenglykol‐Wasser Kinematic viscosity ethylene...

 Open the catalog to page 8
OEM Flow sensor 200 0.5 ... 150 l/min-9

Huba Control AG Headquarters Schweiz Industriestrasse 17 CH-5436 Würenlos Telefon Niederlassung Deutschland Vestiging Nederland Succursale France Branch Office United Kingdom Unit 13 Berkshire House, County Park Technopôle Forbach-Sud Business Centre, Shrivenham Road

 Open the catalog to page 9

All HUBA CONTROL catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.