1. Catalogs
  2. Huazheng Electric
  3. Huazheng HZXB Variable Frequency Series Resonance Test Device Ac Resonance Test System

Huazheng HZXB Variable Frequency Series Resonance Test Device Ac Resonance Test System
1 /1Page

Huazheng HZXB Variable Frequency Series Resonance Test Device Ac Resonance Test System

Huazheng HZXB Variable Frequency Series Resonance Test Device Ac Resonance Test System
1 /1Page

Catalog excerpts

Huazheng HZXB Variable Frequency Series Resonance Test Device Ac Resonance Test System-1

Fast delivery I 24-hour customer service I customizable 30-300Hz, test voltage 128kV, test time 60min. 2. AC withstand voltage test for 220kV GIS, switches, and circuit breakers, with a test frequency of 30-300Hz, a test voltage not exceeding 495kV, and a test time of 1 minute. 3. AC withstand voltage test for 1 lOkV GIS, switches, and circuit breakers, with a test frequency of 30-300Hz, a test voltage not exceeding 265kV, and a test time of 1 minute. 4. AC withstand voltage test of 35kV/300mm2 cable for 3km, capacitance < 0.5835uF, test frequency 30-300Hz, test voltage 52kV, test time 60min. 5. 10kV/300mm2 cable 6km AC withstand voltage test, capacitance < 2.253uF, test frequency 30-300Hz, test voltage 22kV, test time 5min. 6. AC voltage withstand test for 0.5km of 220kV/630mm2 cable, capacitance < 0.072uF, test frequency 30-300Hz, test voltage 216kV, test time 60min. 7. AC withstand voltage test for full insulation of 110kV/80000kVA main transformer, with capacitance < 0.02uF, test frequency 45-65Hz, test voltage not exceeding 160kV, and test time of 1 minute. 2. Input power: Three-phase 380V input, the frequency is 50Hz; 6. Device output waveform: sine wave 7. Waveform distortion rate: output voltage waveform distortion rate < 1%; 8. Working time: continuous 60min allowed under rated load; overvoltage 1.1 times for 1 minute; 9. Temperature rise: The temperature rise is less than or equal to 65K after continuous operation under rated load for 60min; 10. Quality factor: the device itself Q>30 (f=45Hz); 11. Protection function: It has overcurrent, overvoltage and flashover protection for the tested product (see the variable frequency power supply section for details); 12. Measurement accuracy: system RMS level 1.5;

 Open the catalog to page 1

All Huazheng Electric catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.