1. Catalogs
  2. Huazheng Electric
  3. Huazheng HZCT-100A Transformer CT PT Analyzer Supplier

Huazheng HZCT-100A Transformer CT PT Analyzer Supplier
1 /1Page

Huazheng HZCT-100A Transformer CT PT Analyzer Supplier

Huazheng HZCT-100A Transformer CT PT Analyzer Supplier
1 /1Page

Catalog excerpts

Huazheng HZCT-100A Transformer CT PT Analyzer Supplier-1

HuazhengHZCT-100A CT PT Analyzer Fast delivery I 24-hour customer service I customizable Test use:CT, electromagnetic PT Output:0~180Vrms, 12Arms,36A(peak) CT transformation ratiomeasuring range: 1-40000 Accuracy:±0.1% PT transformation ratiomeasuring range: 1-40000 Accuracy:±0.1% Phase measurement Accuracy:±2min Resolution^.5min Secondary winding resistance measurement range:0~300Q Accuracy:0.2%±2mQ AC load measurement range:0~1000VA Accuracy:0.2%±0.02VA working environmenttemperature: -10oC~50oC, humidity: <90% size and weight:Size: 340 mmx300 mmx140mm weight: <7kg • Full-featured to meet the excitation characteristics (ie, volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio difference, and angle difference of various types of CT (eg, protection, metrology, TP) Such test requirements, but also for various types of PT electromagnetic unit excitation characteristics, transformation ratio, polarity, secondary winding resistance test. • Automatically give corner voltage/current, 10% (5%) error curve, accurate limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence factor (Kr), saturation inductance, etc. • The test meets various types of transformer standards such as GB1208 (IEC60044-1), GB16847 (IEC60044-6), and GB1207, and tests are automatically selected according to the type and level of the transformer. • Based on the advanced low-frequency test principle, it can deal with CT tests with inflection points up to 40KV. • The device uses the international popular square wave method to make the excitation curve more perfect. • Device storage capacity up to a few G, can store hundreds of thousands of test data, power loss is not lost. • The test is simple and convenient, one-button CT direct resistance, excitation, ratio and polarity tests are performed, and in addition to the load test, all other CT tests use the same wiring method. • It is easy to carry and the device contains about 8Kg of total weight of wiring.

 Open the catalog to page 1

All Huazheng Electric catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.