Product catalog summary
Overview
The document introduces three devices: PQA820, MacroTestG3, and CombiG2, emphasizing their integration with the HTanalysis app for improved data management and sharing. The app allows users to connect these instruments with tablets and smartphones, facilitating detailed report creation and sharing via the HTCloud database.
HTanalysis App Features
  • Displays and analyzes measurements such as voltage, current, power, harmonics, THD%, cosphi, and frequency.
  • Provides instant visualization of waveforms, vector diagrams, and harmonics.
  • Enables storage and sharing of recordings via HTCloud.
  • Allows creation of comprehensive reports with multimedia elements.
MacroTestG3 Features
  • Conducts all electrical safety tests according to IEC/EN61557-1 standards.
  • Performs advanced loop testing for MCBs, fuses, and cable sizing.
  • Measures earth resistance using various methods.
  • Tests RCDs for different types and currents.
  • Conducts insulation and continuity testing.
  • Measures environmental parameters with external probes.
Technical Specifications
  • Continuity measurement range: 0.01Ω to 99.9Ω with 200mA test current.
  • Insulation resistance test voltages: 50V to 1000VDC.
  • Line/Loop impedance measurement range: 0.01Ω to 199.9Ω.
  • Capabilities for earth resistance and ground resistivity measurement.
  • RCD tripping time and current testing with optional accessories.
  • Power and load analysis for single and three-phase systems.
Advanced Testing Capabilities
  • High-resolution loop impedance measurement with optional accessories.
  • Earth resistance measurement without auxiliary rods using innovative algorithms.
  • Comprehensive power and harmonics analysis up to the 25th harmonic.
General Specifications
  • Power supply: 6x1.2V rechargeable or 6x1.5V alkaline batteries.
  • Display: 320x240 resistive color LCD with touch screen.
  • Memory: 999 locations with 3 marker levels.
  • PC interface: Optical/USB and Wi-Fi.
  • Safety and compliance: IEC/EN61010-1, double insulation, CAT III 240V.
PQA820 Specifications and Features
The PQA820 is a power quality analyzer capable of measuring and recording various electrical parameters such as AC/DC TRMS voltage and current, active/reactive/apparent power, and energy. It supports harmonic analysis up to the 49th order and can detect voltage anomalies like sags and swells with a 10 ms resolution. It features built-in Wi-Fi and USB ports for PC connection.
Standard and Optional Accessories
Standard accessories include cables, alligator clips, a carrying bag, a remote switch probe, a stylus, a rechargeable battery, and a calibration certificate. Optional accessories enhance measurement capabilities, such as transducers for AC currents, impedance measurement adapters, and temperature/humidity sensors.
Measurement Capabilities
The PQA820 can record up to 383 parameters simultaneously, including voltages, currents, power factors, and harmonics. It supports both single-phase and three-phase systems and offers real-time analysis through the HTanalysis App, available for iOS and Android devices.
Data Analysis and Recording
The device provides detailed data analysis with features like zoom and jump functions for easy navigation through recorded data. It supports integration periods ranging from 5 seconds to 60 minutes and can record data for over 30 days.
Environmental and Safety Standards
The PQA820 is designed to withstand harsh environments with an IP65 rating, ensuring protection against dust and water. It complies with safety standards IEC/EN61010-1 and is suitable for use in CAT IV 300V environments.
Technical Specifications
The document provides detailed technical specifications, including measuring ranges, accuracy levels, and resolution for various parameters. It also includes information on the device's dimensions, weight, power supply, and operating conditions.
Conclusion
The PQA820 is a versatile and robust power quality analyzer suitable for a wide range of applications. Its comprehensive measurement capabilities, combined with advanced data analysis features and environmental resilience, make it a valuable tool for monitoring and optimizing electrical systems.
See more

Catalog excerpts

MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-2

Artificial Intelligence. Thanks to the creation of App HTanalysis it is possible to interface HT last generation instruments with tablets and smartphones. HTanalysis is a professional software allowing to display and look at measurements or recordings on your devices then sharing them on HTCloud database. HTanalysis permits to create professional reports complete with pictures, texts, video and voice notes. Interfacing the instrument with your device’s display you can look at a fast and detailed tracking of the recorded quantities on touch-screen. With PQA820 › enables you to display recordings...

 Open the catalog to page 2
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-3

Share. Whenever, whatever and wherever. Install App HTanalysis to avail yourself of HTCloud database and share measurement results and recordings with your colleagues from any place on the planet.

 Open the catalog to page 3
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-4

I'm pure technology. Touch me, please.

 Open the catalog to page 4
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-5

Clear answer. Complying o not. Share. Whenever, whatever and wherever* › O ne instrument for all electrical safety tests according to › dvanced Loop. Testing of MCBs, fuses and cable sizing. A › resistance with 2- or 3-pole volt-ampere method in TT, TN and IT Earth systems, non-trip earth loop impedance measurement, stackless earth ground resistance measurement with T2100 (optional). Soil resistivity. › easurement of electrical parameters in single phase installations M Save time! You will take half time! Color Touch Screen with icon intuitive graphics Power measurement App HTanalysis for iOS™...

 Open the catalog to page 5
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-6

• Test on general, selective and delayed RCDs . Test on RCDs with external toroidal transfor- • Test mode xVz, x1, x2, x5 and AUTO to make 6 test sequences. • Ramp: measurement of real tripping current. 'with optional accessory RCDX10. Selection of RCD type and tripping Selection of tripping current on RCDs Setting of RCD delayed time anient with external toroidal transformer AUTO test result on RCD Ramp test result on RCD Insulation resistance • AUTO function • Rapid setting of limit values and test voltages through virtual keyboard. • Setting of Timer for the test • Calibration of measuring...

 Open the catalog to page 6
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-7

Measurement of phase sequence SEQ Check of phase sequence with 1 or 2 terminals. Check of phase compliance. Measurement of leakage currents Leakage current can be measured with external clamp HT96U (optional). Virtual keyboard to enter comments. Saving on file structure. N ew detailed reports with TopView software. Saving with file tree Entering comments on measurements Transfer of data to PC by TopView software HTanalysis™ and HTCloud™ App HTanalysis will change your working concept. During testing you can: • Dictate comments orally • Associate a picture or a video to each measurement • Review...

 Open the catalog to page 7
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-8

Advanced Loop Testing of MCBs, fuses and cable sizing. For the first time ever. For the first time you will be able to check whether a complex system is working in compliance with standards. HT enriched loop measurement including functions and tests which were earlier possible just thanks to project-oriented calculations. The rules of the game? We know all the answers. I n order to protect power lines, IEC/EN61557-1 standards require designers to size the installation to grant: • protection against indirect contacts • protection against short circuits. MacrotestG3 is quite familiar with standards...

 Open the catalog to page 8
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-9

Testing of protection against indirect contacts (TT-TN-IT systems) When an earth fault occurs masses can become potentially dangerous as long as protection trips out. The instrument checks that danger does not overcome the limits set by the standards. For example in a TN system after setting the curve type and tripping time of MCB the instrument calculates short circuit current with positive outcome if MCB trips out before contact voltage becomes dangerous. Testing of MCB tripping time. If MCBs comply with tripping times provided by the standards the instrument will indicate positive outcome....

 Open the catalog to page 9
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-10

Tech specs Continuity with 200mA Power and Load Analysis Measuring range: 0,01Ω÷99.9Ω Accuracy: ±(5.0% reading + 3 digits) Test current: > 200mA (R ≤ 2Ω) Open circuit voltage: 4V ≤ V0 ≤ 12V Insulation resistance and apparent power measurement › Cosphi, power factor measurement › Single Phase and Three Phase balanced systems › Voltage,Current and frequency measurement › Active power, reactive power Measuring range: 0.01Ω ÷ 199.9Ω Resolution: 0.01Ω min (0.1mΩ with optional accessory IMP57) Accuracy: ±(5.0% reading + 3 digits) Test voltage: 100÷265V (L-N) / 100÷460V (L-L), 50/60Hz Maximum test current:...

 Open the catalog to page 10
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-11

General specifications Non-trip earth loop impedance Active Power (@ 230V in 1Ph systems, 400V in 3 Ph systems, cosphi=1, f=50.0Hz) L-N, L-PE voltage range: 100V ÷ 265V, 50/60Hz ± 5% Measuring range: 0,01Ω÷ 999Ω (systems with neutral) 1 1Ω÷ 999Ω (systems without neutral) 1 Accuracy: ±(5.0% reading + 3 digits) Test current: <15mA Allowed crest factor ≤ 1,5 320x240 resistive color LCD with touch screen 999 locations, 3 marker levels optical/USB and Wi-Fi 225 x 165 x 75 mm / 8.8 x 6.5 x 2.9 in Weight (including batteries) 1.2 kg / 2.5 lb Reactive Power (@ 230V in 1Ph systems, 400V in 3 Ph systems,...

 Open the catalog to page 11
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-12

3-banana to Shuko plug cable Kit including 4 cables, 4 alligator clips and 2 test leads Soft carrying bag containing 4 cables and 4 earth rods Remote switch probe PC software and optical-to-USB connection cable C2006 Rechargeable NiMH battery 1.2V, AA, 6 pcs External battery charger for 8 pcs. type AA batteries user’s guide T ransducer for AC currents (including leakage current) 0 ÷ 1, 0 ÷ 100, 0 ÷ 1000A AC High resolution impedance measurement adapter Earth ground clamp transducer Transducer for temperature/humidity measurement Transducer for illuminance measurement Magnetic adapter for connection...

 Open the catalog to page 12
MACROTESTG3, PQA820, COMBIG2 and HTAnalysis  a new working concept by HT-13

Continuity of earth conductors with 200mA • Earth resistance with 2-wire and 3-wire methods • Earth resistance with clamp •** Ground resistivity with 4-wire methods • Global earth resistance without RCD's tripping • Line/Fault impedance, Phase-Phase, Phase-Neutral, Phase-PE • Line/Fault impedance, Phase-Phase, Phase-Neutral, Phase-PE with high res. (0.1 mO) •* Prospective short circuit/fault current • Contact voltage • General, Selective and Delayed RCD's tripping time • RCD's test current type A, AC max 1A and B type max 300mA • Test on earth leakage delay testers RCD up to 10A • *** RCD trip...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.