Catalog excerpts
JUPITER MUL TIMETER & MUL TIFUNCTION
Open the catalog to page 1You might think I am just a multimeter... 690V › Autorange measurements with automatic AC/DC detection. › DC, AC TRMS, AC+DC TRMS voltage up to 690V. › impedance voltage input to eliminate ghost voltage readings. Low › DC, AC TRMS, AC+DC TRMS current by means of external transducer. › Frequency of voltage and/or current. › Resistance and continuity with buzzer. › MIN/MAX/PEAK/HOLD functions. › 6000 counts. TRMS AC+DC current measurement. AC current measurement with flexible transducer F3000U. RCD tripping time and current measurement. Current harmonic measurement. My name is Jupiter. Why to...
Open the catalog to page 2... but I have a multifunction soul! RCD tripping time and current: full control! RCD tripping time and current. › can measure the tripping time of RCDs type A and AC up to 300mA** and the tripping current of RCDs type I AC up to 30mA (RAMP test). › y AUTO function makes everything more immediate: my display will show you the 6 consecutive tests (x1/2, M x1, x2, x5, 0°, 180°) for a full RCD check. › will show you an unequivocal response OK or NOT OK. I I’m Jupiter... and I’ll show you the Earth. Non-trip earth ground resistance and Line (Loop) impedance. › TT systems I measure the non-trip...
Open the catalog to page 4Ghost voltage cancellation. Non-trip earth ground resistance measurement. Leakage current measurement. Measurement comparison: 3.9A: with RMS clamp - 4.7A: with TRMS clamp 6.1A: correct reading with AC+DC TRMS clamp. Inrush Current measurement.
Open the catalog to page 5Optional accessories • F3000U AC flexible clamp with 30/300/3000A full scales • HT96U* AC current clamp with 1/100/1000A full scales • HT97U* AC current clamp with 10/100/1000A AC full scales • HT98U* DC current clamp with 1000A full scale • HT4006 AC/DC current clamp with 40/400A full scales • NOCANBA Hypertac-to-banana adapter * Adapter NOCANBA required. Technical specifications DC Voltage Measurement range: 0.0V rn 690.0V Resolution: 0.1V Accuracy: ±(0.5%reading + 2digits) AC TRMS, DC, AC+DC TRMS, LoZ Voltage Measurement range: 0.5V rn 690.0V Frequency range: 32Hz rn...
Open the catalog to page 6All HT catalogs and technical brochures
-
Catalogue 2O24
110 Pages
-
HOT
8 Pages
-
NRG
8 Pages
-
SUN
12 Pages
-
PV-ISOTEST
4 Pages
-
GENERAL CATALOGUE 2021
94 Pages
-
THERMAL CAMERAS
11 Pages
-
ACCESSORIES CATALOGUE
35 Pages
-
QUICK PICK GUIDE
19 Pages
-
THT70 & THT60 Infrared cameras
12 Pages
-
MERCURY
2 Pages
-
Brochure I-V500w -1500V
9 Pages
-
New Digital Infrared cameras
12 Pages
-
General Catalogue 2016
120 Pages
-
NEW PV TESTER LEAFLET
16 Pages