Water needs a future! High throughput (little losses) through optimized bar form Because of pre-stressed bars - no bridges necessary - no braiding for qualitative stormwater treatment at basin overflows, separation structures, combined sewer overflows and similar type overflow structures. to ensure operation at inlet channels of retention- and soil filters Variable installation and alignment Completely automated gentle cleaning HSR-Fine Screen High protection class (IP 68) Standard bar clearances of 4/6/8 mm for optimal operational safety High reliability and operational safety HSR-high performance bar screen for coarse, fine and floating h solids retention Fully automated forced mechanical cleaning High retention level through small bar clearances and utilization of the filter effect of the screenings Retrofitting in existing structures OUR SERVICES Design support, sizing and dimensioning, providing of CAD-files, Technology advice, start up, maintenance and repair, optimizations We would love to advice you and create a noncomittal proposal, customized to your individual needs. Meschede HST Hydro-Systemtechnik GmbH Sophienweg 3 · D-59872 Meschede Tel. +49-2 91-99 290 Fax +49-2 91-76 91 e-mail: [email protected] High hydraulic throughput/ minimal losses through flow conducive bar for
Open the catalog to page 1HSR-FINESCREEN Fine screens in combination with backflow flap gates complement each other perfectly This is how the HSR Screen works: The HSR Screen is placed on top of the weir crest. Coarse, fine and floating solids are retained through the bar structure and screenings deposits (filter mat) during overflow events. The TeleMatic control is constantly checking the upstream water level to control the cleaning frequency based on upstream water levels. During a cleaning event, the clearances between the bars are scoured and cleared of debris. Cleaning happens in front of and between the bars. The...
Open the catalog to page 2HSR-FINESCREEN Fine screens in combination with backflow flap gates complement each other perfectly This is how the HSR Screen works: The HSR Screen is placed on top of the weir crest. Coarse, fine and floating solids are retained through the bar structure and screenings deposits (filter mat) during overflow events. The TeleMatic control is constantly checking the upstream water level to control the cleaning frequency based on upstream water levels. During a cleaning event, the clearances between the bars are scoured and cleared of debris. Cleaning happens in front of and between the bars. The...
Open the catalog to page 3Water needs a future! High throughput (little losses) through optimized bar form Because of pre-stressed bars - no bridges necessary - no braiding for qualitative stormwater treatment at basin overflows, separation structures, combined sewer overflows and similar type overflow structures. to ensure operation at inlet channels of retention- and soil filters Variable installation and alignment Completely automated gentle cleaning HSR-Fine Screen High protection class (IP 68) Standard bar clearances of 4/6/8 mm for optimal operational safety High reliability and operational safety HSR-high performance...
Open the catalog to page 42 Pages
97 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages