HRS DTA SERIES
1Pages

{{requestButtons}}

Catalog excerpts

HRS DTA SERIES - 1

HRS DTA SERIESHYGIENIC DOUBLE TUBE HEAT EXCHANGER The HRS DTA Series is a complete stainless steel double tube design for hygienic applications. The product flows through the inner tubes and the media fluid flows through the surrounding shell. Because of its geometry, the DTA Series is a true counter current heat exchanger. Using our corrugation technology, both heat transfer and efficiency are increased over standard smooth tube heat exchangers. In addition potential fouling is minimised. APPLICATIONS Fluids Containing Fibres or other Particles Low-High Viscosity Fluids MATERIALS OF CONSTRUCTION FEATURES Corrugated tubes for increased heat transfer Bellow fitted to absorb differential expansion between shell and tube Multiple units can be interconnected and have the option of frame mounting, insulation and cladding in stainless steel Shell Side: AISI 304 Stainless Steel Tube Side: AISI 316L Stainless Steel STANDARD CONNECTIONS Shell Side: Flange Tube Side: Clamp SURFACE FINISH External: Satin or Polished Tube Side: Roughness < 0.8 g STANDARD DESIGN CONDITIONS Shell side: 10 barg/150° C Tube side: 10 barg/150° C Lengths Surface Area (m) (m2) The surface area and volumes shown are for 6.0 meter length models ©2016 HRS Heat Exchangers All rights reserved www.hrs-heatexchangers.com info@hrs-he.com

Open the catalog to page 1

All HRS Heat Exchangers catalogs and technical brochures