Document Overview: This document provides a standard torque table for the NFS Wedgegard® Coupling, detailing the torque ratings for various codes and configurations. The ratings are given in Newton-meters (Nm) and are approximate values per single Wedgepin fitted.
Specifications: The document lists torque ratings for different coupling codes, including S350, S500, S700, S950, and their respective configurations such as W37, W50, W100, etc. Each configuration has specific torque ratings under different conditions (e.g., O, OW, GD, W, WY, Y, YB, BN, B, BG, G, RG, R, RK, K).
Key Data: The table provides torque values for each configuration, indicating the performance capabilities of each coupling type. For example, the S350 code with a W37 configuration has a torque rating of 45 Nm under condition O, while the S950 code with a W100 configuration has a torque rating of 5600 Nm under condition K.
Important Notes: The document notes that dimensions and specifications may change without notice for improvement purposes. It is crucial for users to verify the latest specifications before application.
Contact Information: For further inquiries, Howdon Power Transmission Limited can be contacted via phone, email, or through their website and Twitter handle.