Rotameter series 250
8Pages

{{requestButtons}}

Catalog excerpts

Rotameter series 250 - 1

Technical data Sheet 50466-615 July 2017 Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES ● 250 Stainless Steel indicator ● 250 PTFE ● 250 indicator + Alarm ● 250 electronic transmitter 4-20mA ● 250 electronic transmitter 4-20mA ADF Houdec Innovat

Open the catalog to page 1
Rotameter series 250 - 2

Flow meter Technical data Sheet 50466-615 July 2017

Open the catalog to page 2
Rotameter series 250 - 3

Technical data Sheet 50466-615 July 2017 Flow meter Principle The instrument must be mounted in a vertical pipe with fluid circulation in the upwards direction. The self guiding cylindrical float is positioned inside a tapered tube. When the flow passes through the meter the float rises to a position of equilibrium where the weight of the float is balanced by the net force due to the fluid pressure. The float is magnetically coupled to a pointer indicating the rate of flow on the front scale. Applications The metal tube 250 series variable area flow meter is a specially designed instrument...

Open the catalog to page 3
Rotameter series 250 - 4

Technical data Sheet 50466-615 July 2017 Flow meter Technical characteristic Precision : 2% of the maximum capacity (PTFE 3%) (class 1.6 VDI; VDE 3513 on request). Report/ratio of scale: 1 to 10 Extended of scale: to see table “Ranges of flows”. Stainless ≤ 40 bar out of standard Pressure of service: Up to 200 bar on request Note: With liquids, the operating pressure must be Tige guide at least equal to two time pressure losses of de flotteur the apparatus. At least five times with gases. Temperature of service Stainless Version: -40 with + 200°C Version PTFE: -20 with + 125°C Heat shield...

Open the catalog to page 4
Rotameter series 250 - 5

Technical data Sheet 50466-615 July 2017 Flow meter ALARM OPTION • Intrinsic safety version « ia » Detectors with D.C. current 2 wire (SJ3,5. NR. Pepperl&Fuchs) of S.I Index réglable alarme haute Contact numbers 2 adjustable (high and/or low alarm) on the totality of the scale Note: Adjustment accessible on the dial with visual witness on the scale from flow. Can be associated the electronic transmitter. Connection on terminals with screw S=2,5mm ². Exit out of standard on press packs polycarbonate PG9 cables Ø 5 to 8 Misters. Nominal voltage 8V= (IH ~ 1 k ) Tension of service No-load...

Open the catalog to page 5
Rotameter series 250 - 6

Technical data Sheet 50466-615 July 2017 Flow meter ELECTRONIC TRANSMITTER OPTION Standard VERSION (Pointer and scale plate indicator) – "T5 code" Output signal: Transmission: Power supply: :d’alimentation Linearity: Temperature deviation: Permissible ambient temperature: 4 à 20mA proportional from 10 to 100% of flow range 4mA corresponds to 0 of the scale (setted position marked --0). 5,6 mA corresponds to 10% of the fullscale (first measuring value 10%). 20mA corresponds to 100% of the full scale (top measuring value 100%). 2 wires (connection : see alarm) UB = 8 to 24 Vcc. 0,5% of max....

Open the catalog to page 6
Rotameter series 250 - 7

Technical data Sheet 50466-615 July 2017 Flow meter INSTRUMENT TYPE Code Connection code 15 ISO PN Flange NFE 29203/ NE1092 - DN15 25 ISO PN Flange NFE 29203/ NE1092 - DN25 50 ISO PN Flange NFE 29203/ NE1092 - DN50 80 ISO PN Flange NFE 29203/ NE1092 - DN80 100 ISO PN Flange NFE 29203/ NE1092 - DN100 1/2" Flange ANSI B16-5 DN 1/2" 1" Flange ANSI B16-5 DN 1 2" Flange ANSI B16-5 DN 2" 3" Flange ANSI B16-5 DN 3" 4" Flange ANSI B16-5 DN 4" I Code Measuring element code I M.. See flow range table I I Code Construction code I I C1 STAINLESS STEEL 316, ISO PN16 Flange RF I I C2 STAINLESS STEEL 316,...

Open the catalog to page 7
Rotameter series 250 - 8

Flow meter Technical data Sheet 50466-615 July 2017 LIMITS CERTIFICATES Of INDIVIDUAL CALIBRATION BNM 2% or 1.6% VDI-VDE: Gas : 0,5 l/h to 55 m3/h Liquids : 0.1 l/h to 45 m3/h Standard certificate 2%: Gas : 0,5 l/h to 300 m3/h Liquids : 0.1 l/h to 100 m3/h Models PTFE: 3% TECHNICAL DATA FOR ESTIMATE/ORDER - Nature of the measured fluid (standard, group of dangerosity), - Minimum Flow and desired maximum, - Density, - Viscosity in the operating conditions, - Temperature of service of the measured fluid, - Operating Pressure of the fluid. Information required for quote or order: - Fluid type...