1. Catalogs
  2. HORIBA Scientific
  3. Sample Preparation
video corpo

Sample Preparation

Sample Preparation

Sample Preparation

Product catalog summary
Overview: The document provides a comprehensive overview of various sample preparation systems and certified reference materials offered by HORIBA for scientific applications. These systems are designed to enhance accuracy, efficiency, and safety in laboratory settings.
Certified Reference Materials: HORIBA offers a wide range of certified reference materials for calibration, control, and validation across various analytical techniques such as ICP, AA, ICP-MS, GC, HPLC, CI, XRF, GDS, CS, and ONH analyzers. These materials are traceable to NIST and are available in different forms including liquids, chips, powders, blocks, and disks. The stability of solutions is guaranteed for 12 to 18 months.
Sample Preparation Systems:
  • Vigorous Vertical Shaker Mill (Genogrinder): Capable of grinding up to 384 samples using titer plates or 16 samples by centrifugation. It preserves DNA/RNA during grinding and is suitable for applications like pesticides analysis and DNA/RNA extraction.
  • Microwave (QLabPro): Used for mineralization, extraction, evaporation, or synthesis of samples. It can handle up to 30 samples per cycle with a heating capacity of 230°C, applicable in fields like geology and food chemistry.
  • Automatic Sample Dilution (QPrep): Facilitates dilution of up to 360 samples per cycle, improving precision and accuracy for ICP, OES, ICP-MS, and AA standards preparation.
  • Tubular and Muffle Furnace: Offers temperatures up to 1100°C for fast combustion and temperature ramps, suitable for C/S analysis and decontamination processes.
  • Ball Mill (Mixer Mill): Grinds samples down to nanometer size and is used for applications involving rocks, cement, and pigments.
  • Cryogenic Grinder (Freezer Mill): Operates at -190°C for grinding thermosensitive samples, preserving DNA/RNA and volatile compounds.
  • Borate Fusion (Single & Six Positions Electric Fluxer): Prepares glass disks for XRF and alkaline fusions for AA and ICP analysis, ensuring user safety.
  • Sample Digestion (Vulcan): Automates digestion steps for up to 144 samples per cycle, dedicated to ICP and AA analysis.
  • Disc Grinder (Shatterbox): Grinds samples down to 20 µm grains, suitable for mining samples and geology.
  • Nickel Capsules Press: Facilitates easy folding of Nickel capsules for elemental analysis.
  • Heating Blocks (Qblock): Provides heating up to 230°C with customizable blocks, compatible with the VULCAN digestion station.
  • Pelletizing (X Press): Offers manual or automatic pressing for XRF, IR, and GD analysis, producing pellets in under two minutes.
Conclusion: HORIBA's sample preparation systems and certified reference materials are designed to improve laboratory efficiency, accuracy, and safety across various scientific fields, including geology, metallurgy, environment, and biochemistry.
See more

Catalog excerpts

Sample Preparation-1

Certified reference materials Sample Preparation Calibrate, control, validation for Efficient, automatic, fast, safe for the operators ICP, AA, ICP-MS, GC, HPLC, CI, XRF, GDS, CS & ONH analyzers u Different sources according to techniques and accreditation requirements u ono or multi-elements reference materials M u Reference materials traceable to NIST u Stability of solutions gauranteed for 12 or 18 months u 0,000 standards reference: liquids, chips, powders, blocks, disks 1 Document non contractuel - Les spécifications sont susceptibles d’être modifées sans préavis - ©HORIBA Jobin Yvon- 12/2013 Furnace Fusion Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific www.horiba.com/scientific Explore the future Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific

 Open the catalog to page 1
Sample Preparation-2

An efficient sample preparation for accurate results Cryogenic Grinder Freezer Mill Ball Mill Mixer Mill Vigorous Vertical Shaker Mill Genogrinder Grinding up to 384 samples by titer plates, or 16 samples by centrifugation. Grinding completed in 1-2 minutes with adjustable speed between 500 and 2000 strokes/min. DNA/ RNA preservation during the cells’ grindings, cryogenic station available as an option. Grinding of 0.2 g to 20 g of sample down to nanometer size, emulsion production up to 60 ml volume and powders blending. Containers available as an option to fit specific applications. High shaking...

 Open the catalog to page 2

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4  Pages

  2. PX-375

    6  Pages

  3. NanoRaman

    7  Pages

  4. 51 series

    6  Pages

  5. KiloArc

    2  Pages

  6. PowerArc

    2  Pages

  7. Laqua

    24  Pages

  8. Duetta

    8  Pages

  9. MacroRAM

    2  Pages

  10. PSA300

    5  Pages

  11. CAMSIZER XT

    12  Pages

  12. SZ-100

    4  Pages

  13. XPLORER-TX/TS

    6  Pages

  14. XPLORER-NS

    6  Pages

  15. EMIA series

    6  Pages

  16. GD PROFILER

    7  Pages

  17. XGT-7200

    2  Pages

  18. Ultima Expert

    5  Pages

  19. EMGA-921

    4  Pages

  20. EMGA-920

    4  Pages

  21. EMGA-930

    4  Pages

  22. EMIA-V2

    14  Pages

  23. VS-20

    6  Pages

  24. CLUE Series

    6  Pages

  25. XploRA One

    2  Pages

  26. XploRA Series

    5  Pages

  27. Model H1034B

    2  Pages

  28. VS20

    6  Pages

  29. Ultima Expert

    5  Pages

  30. Forensics

    2  Pages

  31. OpenPlex

    2  Pages

  32. AFM Raman

    2  Pages

  33. MESA-50

    2  Pages

  34. Dual-FL

    7  Pages

  35. Aqualog

    6  Pages

  36. Smart SE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.