Introduction
The document introduces the NanoLog™ modular spectrofluorometer, optimized for detecting nanomaterials' near-IR fluorescence. It is based on the proven technology of the Fluorolog® from Spex® Fluorescence and is designed for reliable service and expert assistance.

Modularity
The NanoLog™ is a customizable instrument, allowing users to select components such as the source, monochromators, sample compartment, emission spectrometer, and detector to suit their experimental needs and budget.

Recommended Configurations
  • Good: NanoLog™ 3-11 with single-grating excitation and emission monochromators and IGA-020 near-IR solid-state photodiode for economical studies.
  • Best: NanoLog™ 3-22-TRIAX with double-grating excitation and emission monochromators, an imaging spectrograph, and extended InGaAs array for sensitive detection.

Versatility
The NanoLog™ offers a variety of detectors, including photomultiplier tubes, solid-state photodiodes, CCD arrays, and InGaAs arrays, providing a wide range of detection capabilities.

Automation
The NanoLog™ features self-calibration and automatic settings for wavelengths and slits. The FluorEssence™ software provides powerful data acquisition, and the Nanosizer™ software offers advanced analysis for single-walled carbon nanotubes.

Exclusivity
HORIBA Jobin Yvon offers a wide variety of components and software, along with global support, ensuring users can maximize the potential of their NanoLog™.

Real Nanomaterials Performance
The NanoLog™ can perform excitation-emission matrix scans on single-walled carbon nanotubes, with the Nanosizer™ software determining chirality and diameter from the spectral data.

Specifications
  • Excitation Source: 450 W xenon short-arc with off-axis mirror for maximum efficiency.
  • Resolution: 0.2 nm for excitation, 4.2 nm for emission.
  • Accuracy: 0.5 nm for excitation, 0.3 nm for emission.
  • Range: 0–1300 nm for excitation, 0–1500 nm for emission.
  • Detectors: InGaAs multi-channel array for rapid emission spectra, with options for higher-wavelength emissions.
  • Sensitivity: Steady-state S/N of 4000:1 at 397 nm.
See more

Catalog excerpts

Nanolog - Modular Spectrofluorometer for Nanotechnology-2

Your best answer to analyzing your mixtures of nanomaterials, whether single-wall carbon nanotubes, quantum dots, or nanocrystals. Optimized for detecting nanomaterials’ near-IR fluorescence, the NanoLog™ modular spectrofluorometer can help you determine their composition and structure. Based on the proven technology of the world-renowned Fluorolog® from Spex® Fluorescence, the NanoLog™ is designed to give you a long life of reliable service and expert assistance. Modularity Create your own customized NanoLog™ from a proven series of components to suit your needs. The NanoLog™ is a modular instrument,...

 Open the catalog to page 2
Nanolog - Modular Spectrofluorometer for Nanotechnology-3

Automation The NanoLog™ is easy to use! Hardware The NanoLog™ is self-calibrating. Wavelengths and slits, accessories and sample turrets are all automatic, so you don’t have to worry about reproducible settings. Software Our NEW FluorEssence™ software is a powerful data-acquisition package. Add to that our NEW Nanosizer™ with our patented double-convolution-integral algorithm specially designed for determining chirality and diameter of singlewalled carbon nanotubes, and you get the most advanced nanomaterials system ever built. FluorEssence™ includes: I Simplified drop-down menus I Detector-algebra...

 Open the catalog to page 3
Nanolog - Modular Spectrofluorometer for Nanotechnology-4

Specifications Excitation Source 450 W xenon short-arc. Collection and focusing by off-axis mirror for maximum efficiency at all wavelengths. Excitation Monochromator Czerny-Turner with kinematic gratings and all-reflective optics. Optional double-grating units available for highest stray-light rejection and sensitivity. (Specifications based on 1200 grooves/mm grating, but other gratings are available) Resolution 0.2 nm Accuracy 0.5 nm Speed 150 nm/s Range 0–1300 nm mechanical range; throughput based on grating’s blaze Gratings 500 nm blaze for excitation (300–1200 nm range); other gratings...

 Open the catalog to page 4

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4  Pages

  2. PX-375

    6  Pages

  3. NanoRaman

    7  Pages

  4. 51 series

    6  Pages

  5. KiloArc

    2  Pages

  6. PowerArc

    2  Pages

  7. Laqua

    24  Pages

  8. Duetta

    8  Pages

  9. MacroRAM

    2  Pages

  10. PSA300

    5  Pages

  11. CAMSIZER XT

    12  Pages

  12. SZ-100

    4  Pages

  13. XPLORER-TX/TS

    6  Pages

  14. XPLORER-NS

    6  Pages

  15. EMIA series

    6  Pages

  16. GD PROFILER

    7  Pages

  17. XGT-7200

    2  Pages

  18. Ultima Expert

    5  Pages

  19. EMGA-921

    4  Pages

  20. EMGA-920

    4  Pages

  21. EMGA-930

    4  Pages

  22. EMIA-V2

    14  Pages

  23. VS-20

    6  Pages

  24. CLUE Series

    6  Pages

  25. XploRA One

    2  Pages

  26. XploRA Series

    5  Pages

  27. Model H1034B

    2  Pages

  28. VS20

    6  Pages

  29. Ultima Expert

    5  Pages

  30. Forensics

    2  Pages

  31. OpenPlex

    2  Pages

  32. AFM Raman

    2  Pages

  33. MESA-50

    2  Pages

  34. Dual-FL

    7  Pages

  35. Aqualog

    6  Pages

  36. Smart SE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.