EMGA 930 Oxygen/Nitrogen/Hydrogen Combustion Analyzer
4Pages

{{requestButtons}}

Catalog excerpts

EMGA 930 Oxygen/Nitrogen/Hydrogen Combustion Analyzer - 1

Specifications Product name Oxygen/Nitrogen/Hydrogen analyzer Oxygen: Non Dispersive Infrared detector (NDIR) Nitrogen: Thermal Conductivity detector TCD Hydrogen: Non Dispersive Infrared detector (NDIR) Measurement range* 1) One point or multi point calibration (Reference gas or standard samples) 2) Calibration using previous analysis data 1) Display of realtime extraction curve 2) Analysis interruption 3) Self diagnosis and alarm display 4) Analysis of extraction curve 5) Output (RC-232C or TCP/IP) 750mm(H) 785mm(D) 653mm(W) Sample window is positioned at 650mm from table. 3) Calibration curve correction function *Up to 100% wt is possible by decreasing the sample weight. Sample weight 1g as standard condition, possible to decrease Sensitivity (Minimum reading) Precision (Repeatability) Oxygen/Nitrogen: SD 0.02μg g or RSD 0.5% whichever is larger (Reference gas) Hydrogen: SD 0.04μg g or RSD 2.0% whichever is larger (Reference gas) 230kg: For transportation, the system can be split into 2 units < 140 kg each 1) Measurement result: PC or printout 2) Alarm message: PC or printout 3) Flow sheet: PC Main unit: AC200/220/230/240V ± 10% Vacuum cleaner: AC100V (Step-down transformer included) Frequency: 50/60Hz Type and power of furnace Impulse furnace with inert gas fusion with power variable from 0 to 8.0kw Sample introduction Dual sample/flux introduction mechanism Automation functions Auto cleaner, Crucible loader Integration conditions Preset integration times, integration time to reach the comparator level or both with the shortest time used. Enter up to 20 characters Main unit: 12kVA (MAX) Vacuum cleaner: 1.5kVA (MAX) Less than 10 Installation condition Operation temperature: 5-40 Optimum temperature: 5-35 Humidity: Maximal relative humidity 80%RH between 5-31 , Linearly decrease down to 50%RH between 31-40 Vibration: Duplex amplitude 20micron and less than 0.098m/S2 accelerations at frequency band Electric power consumption Ground resistance He carrier gas: Purity greater than 99.995%, Pressure 0.35MPa Stainless steel tube(O.D.3mm) and suitable connecter fitting within 3m of unit Dry air or N2 as operating gas: Pressure 0.45MPa Nylon pipe(O.D.6mm) and suitable connecter fitting within 5m of unit Other available models EMGA-830AC: same performance as EMGA-930 but without crucible loader EMGA-830M: same performance as EMGA-930 but without crucible loader and auto cleaner Cooling mechanism Dimensional outline drawing Separate Water Cooler unit Electronic balance: option Enable connection with electronic balance with 1-0.01mg sensitivity Automatic voltage regulator (AVR): option Installation example Oxygen Nitrogen Hydrogen

Open the catalog to page 1
EMGA 930 Oxygen/Nitrogen/Hydrogen Combustion Analyzer - 2

Fully Supported Accessories In Pursuit of High performance/ Speed/Operability EMGA-930 is a simultaneous oxygen/nitrogen/hydrogen elemental analyzer with high accuracy and repeatability repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs. To achieve high-speed and simple operation all accessories are included in the EMGA-930. pp y y Crucible loader (Automated crucible supply system) P recise Precise capture and po ositioning positioning of crucibles...

Open the catalog to page 2
EMGA 930 Oxygen/Nitrogen/Hydrogen Combustion Analyzer - 3

Fully Supported Accessories In Pursuit of High performance/ Speed/Operability EMGA-930 is a simultaneous oxygen/nitrogen/hydrogen elemental analyzer with high accuracy and repeatability repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs. To achieve high-speed and simple operation all accessories are included in the EMGA-930. pp y y Crucible loader (Automated crucible supply system) P recise Precise capture and po ositioning positioning of crucibles...

Open the catalog to page 3
EMGA 930 Oxygen/Nitrogen/Hydrogen Combustion Analyzer - 4

Vacuum/control units Vacuum and control units can main unit power cable (with grounding) Converter C-550 Automatic press EX-95 Shown length of pipe and power cable are for accessories Please install with enough space http://www.horiba.com e-mail: info@horiba.co.jp Head Office Miyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Tokyo Sales Office Chiyoda-ku, Tokyo, Japan TAIWAN Representative Office • HORIBA TRADING (SHANGHAI) CO., Ltd. Shanghai Office Room 1701, United Plaza, Beijing Office Room 1801, Capital Tower, Chaoyang District, Beijing, Choong-ku, Seoul, Korea • HORIBA INSTRUMENTS •...

Open the catalog to page 4

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. Duetta

    8 Pages

  9. MacroRAM

    2 Pages

  10. PSA300

    5 Pages

  11. CAMSIZER XT

    12 Pages

  12. SZ-100

    4 Pages

  13. XPLORER-NS

    6 Pages

  14. EMIA series

    6 Pages

  15. GD PROFILER

    7 Pages

  16. XGT-7200

    2 Pages

  17. EMGA-921

    4 Pages

  18. EMGA-920

    4 Pages

  19. EMGA-930

    4 Pages

  20. EMIA-V2

    14 Pages

  21. VS-20

    6 Pages

  22. CLUE Series

    6 Pages

  23. XploRA One

    2 Pages

  24. Model H1034B

    2 Pages

  25. VS20

    6 Pages

  26. Forensics

    2 Pages

  27. OpenPlex

    2 Pages

  28. AFM Raman

    2 Pages

  29. MESA-50

    2 Pages

  30. Dual-FL

    7 Pages

  31. Aqualog

    6 Pages

  32. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages