Group: HORIBA
Catalog excerpts
Specifications Product name Oxygen/Nitrogen analyzer Oxygen: Non Dispersive Infrared detector (NDIR) Nitrogen: Thermal Conductivity detector TCD Measurement range* 1) One point or multi point calibration (Reference gas or standard samples) 2) Calibration using previous analysis data 1) Display of realtime extraction curve 2) Analysis interruption 3) Self diagnosis and alarm display 4) Analysis of extraction curve 5) Output (RC-232C or TCP/IP) 750mm(H) 785mm(D) 653mm(W) Sample window is positioned at 650mm from table. 3) Calibration curve correction function Oxygen: ~5%(m/m) Nitrogen: ~3%(m/m) *Up to 100% wt is possible by decreasing the sample weight. Sample weight 1g as standard condition, possible to decrease Sensitivity (Minimum reading) Precision (Repeatability) Oxygen/Nitrogen: 0.001μg/g 0.5% whichever is larger (Reference gas) 1) Measurement result: PC or printout 2) Alarm message: PC or printout 3) Flow sheet: PC Type and power of furnace Impulse furnace with inert gas fusion with power variable from 0 to 8.0kw Sample introduction Dual sample/flux introduction mechanism 230kg: For transportation, the system can be split into 2 units < 140 kg each Main unit: AC200/220/230/240V ± 10% Vacuum cleaner: AC100V (Step-down transformer included) Frequency: 50/60Hz Installation condition Operation temperature: 5-40 Optimum temperature: 5-35 Humidity: Maximal relative humidity 80%RH between 5-31 , Linearly decrease down to 50%RH between 31-40 Vibration: Duplex amplitude 20micron and less than 0.098m/S2 accelerations at frequency band He carrier gas: Purity greater than 99.995%, Pressure 0.35MPa Stainless steel tube (O.D.3mm) and suitable connecter fitting within 3m of unit Dry air or N2 as operating gas: Pressure 0.45MPa Nylon pipe (O.D.6mm) and suitable connecter fitting within 5m of unit Separate Water Cooler unit Electronic balance: option Enable connection with electronic balance with 1-0.01mg sensitivity Automatic voltage regulator (AVR): option Preset integration times, integration time to reach the comparator level or both with the shortest time used. Cooling mechanism Auto cleaner, Crucible loader Integration conditions Main unit:12kVA (MAX) Vacuum cleaner: 1.5kVA (MAX) Ground resistance Automation functions Electric power consumption Other available models EMGA-820AC: same performance as EMGA-920 but without crucible loader EMGA-820M: same performance as EMGA-920 but without crucible loader and auto cleaner Dimensional outline drawing Installation example Oxygen Nitrogen
Open the catalog to page 1Fully Supported Accessories In Pursuit of High performance/ Speed/Operability EMGA-920 is a simultaneous oxygen/nitrogen elemental analyzer with high accuracy and repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs. To achieve high-speed and simple operation all accessories are included in the EMGA-920. Crucible loader (Automated crucible supply system) Precise capture and positioning of crucibles by rotary mechanism Maximum stock: 100pcs....
Open the catalog to page 2Fully Supported Accessories In Pursuit of High performance/ Speed/Operability EMGA-920 is a simultaneous oxygen/nitrogen elemental analyzer with high accuracy and repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs. To achieve high-speed and simple operation all accessories are included in the EMGA-920. Crucible loader (Automated crucible supply system) Precise capture and positioning of crucibles by rotary mechanism Maximum stock: 100pcs....
Open the catalog to page 3Vacuum/control units Vacuum and control units car main unit power cable (with grounding) Converter C-550 Automatic press EX-95 Shown length of pipe and power cable are for accessories Please install with enough space http://www.horiba.com e-mail: info@horiba.co.jp Head Office Miyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Tokyo Sales Office Chiyoda-ku, Tokyo, Japan • HORIBA TRADING (SHANGHAI) CO., Ltd. TAIWAN Representative Office Shanghai Office 3F, N0.18 Lane 676, Chung Room 1701, United Plaza, Beijing Office Room 1801, Capital Tower, Chaoyang District, Beijing, Choong-ku, Seoul, Korea •...
Open the catalog to page 4All HORIBA Scientific catalogs and technical brochures
-
SLFA-60.6000
4 Pages
-
PX-375
6 Pages
-
XploRA Series Raman
8 Pages
-
LabRAM Odyssey - Pre booking
2 Pages
-
OMNI TERS Probes
2 Pages
-
NanoRaman
7 Pages
-
51 series
6 Pages
-
LabRAM HR Evolution
5 Pages
-
QPrep Automatic Dilutor
2 Pages
-
KiloArc
2 Pages
-
PowerArc
2 Pages
-
Laqua
24 Pages
-
Duetta
8 Pages
-
MacroRAM
2 Pages
-
PSA300
5 Pages
-
CAMSIZER XT
12 Pages
-
Particle Analyzer CAMSIZER
16 Pages
-
SZ-100
4 Pages
-
LA-960 Series - Partica
10 Pages
-
Plasma Profiling TOFMS
12 Pages
-
Nano-Spectroscopy Solutions
5 Pages
-
PTI QuantaMaster Series
20 Pages
-
SLFA-60/6000 series
4 Pages
-
XPLORER-TX/TS
6 Pages
-
XPLORER-NS
6 Pages
-
EMIA series
6 Pages
-
GD PROFILER
7 Pages
-
XGT-7200
2 Pages
-
XP Examina Forensics Package
4 Pages
-
Ultima Expert
5 Pages
-
XGT 1000WR Brochure
4 Pages
-
IRIS 4.2MP Scientific CMOS
2 Pages
-
iHR550 Imaging Spectrometer
4 Pages
-
FluoroMax Series
20 Pages
-
VS7000 PDA Brochure
2 Pages
-
VS7000 CCD HD Brochure
2 Pages
-
VS7000 CCD HS Brochure
2 Pages
-
Delta Time Brochure
8 Pages
-
Delta Series Brochure
12 Pages
-
FluoroMax-4 TCSPC
2 Pages
-
EMGA-921
4 Pages
-
EMGA-930
4 Pages
-
EMIA-V2
14 Pages
-
VS-20
6 Pages
-
CLUE Series
6 Pages
-
Pulsed RF GD OES
7 Pages
-
Ultima Expert LT
3 Pages
-
LabSpec 6 Spectroscopy Suite
2 Pages
-
XploRA One
2 Pages
-
XploRA Series
5 Pages
-
Model H1034B
2 Pages
-
VS20
6 Pages
-
Ultima Expert
5 Pages
-
Sample Preparation
2 Pages
-
Forensics
2 Pages
-
Spectroscopy solutions
2 Pages
-
OpenPlex
2 Pages
-
AFM Raman
2 Pages
-
iHR Series Spectrometers
6 Pages
-
MESA-50
2 Pages
-
Dual-FL
7 Pages
-
Aqualog
6 Pages
-
Smart SE
2 Pages
Archived catalogs
-
SLFA-60 Brochure
2 Pages
-
JY 2000 2
2 Pages
-
ULTIMA 2
8 Pages
-
ICP-OES ACTIVA-M
12 Pages
-
ICCD
2 Pages
-
InGaAs Array
2 Pages
-
Compact Optical Chopper
1 Pages
-
Accessories for Spectroscopy
1 Pages
-
Symphony CCD Detectors
2 Pages
-
Glow Discharge OES
7 Pages