DynaMyc - Fluorescence Lifetime Mapping Microscope
2Pages

{{requestButtons}}

Catalog excerpts

DynaMyc - Fluorescence Lifetime Mapping Microscope - 1

Technical Specifications Based on upright Olympus BX51 microscope Plan achromat x10 and x40, other magnifications available. 5 position turret Confocal pinhole 4 diameters, from 100 μm to 1000 μm, Motorized, computer-controlled Local Support Camera 8 bits, 2 Mpix, Fluorescence camera (optional) 10 bits, 1.4 Mpix, cooled, low noise in place of standard camera Excitation sources Fiber-coupled pulsed laser sources Repetition rate 10 kHz to 100 MHz, with Delta Diode™ sources Wavelength range Who else can give you the service and applications support you need, in order to achieve the total potential from your instrument? HORIBA Scientific has applications laboratories staffed by fluorescence experts in the USA, Europe, and Asia. HORIBA Scientific’s affiliates and sister companies are in the UK, Germany, France, Italy, China, Korea, and Japan. Add to this a global network of representatives, and you can rest assured that you will have the support you expect only from HORIBA Scientific. We are part of HORIBA, a $1 billion company with more than 5000 employees world-wide. Motorized stage Resolution Travel range Manual control With joystick Automatic control Through DataStation software TCSPC Electronics Single-photon counting detection Lifetime range Dead time TBX picosecond detection module Spectral range Transit spread time Dark count Filters Excitation filters Dichroic filters Motorized, computer-controlled Emission filters 6 positions: BP or long-pass filters Motorized, computer-controlled Motorized, computer-controlled Software Data acquisition DataStation software TCSPC mapping High-speed scan, down to 5 ms per decay Data analysis DAS6 software, inc. reconvolution feature Operating system Windows XP / Windows Vista www.horiba.com/scientific info.sci@horiba.com France: HORIBA Jobin Yvon S.A.S., 16-18 rue du Canal, 91165 Longjumeau cedex - Tel: +33 (0)1 64 54 13 00 - Fax: +33 (0)1 69 09 07 21 - Email: info-sci.fr@horiba.com USA: HORIBA Jobin Yvon Inc., 3880 Park Avenue, Edison, NJ 08820-3012 - Toll-free:+1-866-jobinyvon - Tel: +1 732 494 8660 - Fax: +1 732 549 5125 Email: info-sci.us@horiba.com Japan: HORIBA Ltd., Scientific Instruments Sales Dept., Alte-Building, Higashi-Kanda, 1-7-8 Higashi-Kanda, Chiyoda-ku, 101-0031 Tokyo - Tel: +81 (0)3 3861 8231 Fax: +81 (0)3 3861 8259 - Email: info-sci.jp@horiba.com Germany: HORIBA Jobin Yvon GmbH, Hauptstrasse 1, 82008 Unterhaching - Tel: +49 (0)89 46 23 170 - Fax: +49 (0)89 46 23 17-99 - Email: info-sci.de@horiba.com Italy: HORIBA Jobin Yvon Srl, Via Cesare Pavese 35/AB, 20090 Opera (Milano) - Tel: +39 02 57 60 30 50 - Fax: +39 2 57 60 08 76 - Email: info-sci.it@horiba.com UK: HORIBA Jobin Yvon Ltd, 2 Dalston Gardens, Stanmore, Middlesex HA7 1BQ - Tel: +44 (0)20 8204 8142 - Fax: +44 (0)20 8204 6142 - Email: info-sci.uk@horiba.com China: HORIBA Jobin Yvon SAS, Room 1801, Capital Tower N°6 Jia, Jianguomenwai Av., Chaoyang District, Beijing 100022 - Tel: +86 (0)10 8567 9966 Fax: +86 (0)10 8567 9066 - Email: info-sci.cn@horiba.com Brasil: HORIBA Scientific, Av. das Nações Unidas, 21.735, Bairro Jurubatuba, São Paulo CEP 04795-100 - Tel: +11 5545 1500 - Fax: +11 5545 1570 Email: info-sci@horiba.com Spain: HORIBA Jobin Yvon, C Francisco Silvela 56 Duplicado 2 DIZQ, Madrid 28028 - Tel: +34 91 724 1657 - Fax: +34 91 724 1373 - Email: info-sci@horiba.com Other countries: Tel: +33 (0)1 64 54 13 00 - Email: info-sci@horiba.com Fluorescence Lifetime Mapping Microscope This document is not contractually binding under any circumstances - Printed in France - ©HORIBA Jobin Yvon 09/2011-V2

Open the catalog to page 1
DynaMyc - Fluorescence Lifetime Mapping Microscope - 2

DynaMyc Time-resolved Fluorescence On The Micron-Scale DynaMyc is the ultimate tool to investigate dynamic events in microscopic samples, such as energy transfer and molecular binding. HORIBA Scientific, leader in fluorescence spectroscopy, offers an advanced system to apply time-resolved fluorescence spectroscopy on the micron-scale. l Biological as well as material science samples l Cell and tissue analysis l Intrinsic fluorescence l Conjugated fluorescence labels and quantum dots l Thin films and semiconductors l Fluorescence dyes l Nanoparticles l Quantum dots l FRET FluoroHub...

Open the catalog to page 2

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. Duetta

    8 Pages

  9. MacroRAM

    2 Pages

  10. PSA300

    5 Pages

  11. CAMSIZER XT

    12 Pages

  12. SZ-100

    4 Pages

  13. XPLORER-NS

    6 Pages

  14. EMIA series

    6 Pages

  15. GD PROFILER

    7 Pages

  16. XGT-7200

    2 Pages

  17. EMGA-921

    4 Pages

  18. EMGA-920

    4 Pages

  19. EMGA-930

    4 Pages

  20. EMIA-V2

    14 Pages

  21. VS-20

    6 Pages

  22. CLUE Series

    6 Pages

  23. XploRA One

    2 Pages

  24. Model H1034B

    2 Pages

  25. VS20

    6 Pages

  26. Forensics

    2 Pages

  27. OpenPlex

    2 Pages

  28. AFM Raman

    2 Pages

  29. MESA-50

    2 Pages

  30. Dual-FL

    7 Pages

  31. Aqualog

    6 Pages

  32. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages