
Dual-FL World's Fastest Fluorometer Measure absorbance spectra and fluorescence simultaneously ELEMENTAL ANALYSIS FLUORESCENCE FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING
Open the catalog to page 1100 Times Faster Data Collection The only simultaneous absorbance and fluorescence system available today! The new Dual-FL is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to 100 times faster than with other instruments. Dedicated software automates correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid extraction of information from simple or complex data sets. Hardware Features • The only true simultaneous absorbance-fluorescence system available • TE-cooled CCD fluorescence...
Open the catalog to page 2Aberration corrected double-grating excitation stray-light performance automatic order sorting Aberration corrected emission spectrograph with TE cooled CCD for rapid emission measurements Reference detector to correct fluorescence detector signals Absorbance detector: emission data acquisition
Open the catalog to page 3■ Optimized experiment set-up menus minimize user configuration time ■ Complete NIST-traceable corrected fluorescence spectra automatically generated ■ Spectral and kinetic analysis tools for both absorbance and fluorescence data • Methods and batch protocols for automating multiple sample measurement • Absorbance spectra • Fluorescence emission spectra • Fluorescence emission spectra kinetics • Combined fluorescence emission spectra and absorbance kinetics • Fluorescence excitation-emission matrices (EEMs) • Combined excitation-emission matrices • Single point experiment C:\Documenls and SettingsWl...
Open the catalog to page 4Inner-filter effect correction Rayleigh Masking (1 st and 2nd grating orders) V] File Edit View Collect Analysis Plot Column Worhsheet Statistics Image Tools Format Window Help Multivariate Analysis (Parallel Factor Analysis)
Open the catalog to page 5World's Fastest Fluorometer 17 Second Conventional Fluorometer Data Acquisition 17 Second Dual-FL Data Acquisition
Open the catalog to page 6Fluorescence Hardware Specifications
Open the catalog to page 74 Pages
6 Pages
8 Pages
2 Pages
2 Pages
7 Pages
6 Pages
5 Pages
2 Pages
2 Pages
2 Pages
24 Pages
8 Pages
2 Pages
5 Pages
12 Pages
16 Pages
4 Pages
10 Pages
12 Pages
5 Pages
20 Pages
4 Pages
6 Pages
6 Pages
6 Pages
7 Pages
2 Pages
4 Pages
5 Pages
4 Pages
2 Pages
4 Pages
20 Pages
2 Pages
2 Pages
2 Pages
8 Pages
12 Pages
2 Pages
4 Pages
4 Pages
4 Pages
14 Pages
6 Pages
6 Pages
7 Pages
3 Pages
2 Pages
2 Pages
5 Pages
2 Pages
6 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages
12 Pages
8 Pages
2 Pages
2 Pages
1 Page
2 Pages
7 Pages