CAMSIZER XT
12Pages

{{requestButtons}}

Catalog excerpts

CAMSIZER XT - 1

Particle Analyzer CAMSIZER XT Particle Size and Particle Shape Analysis with dynamic image analysis ders, of fine pow asurement Me ns d suspensio granules an 3 mm om 1 µm to in a range fr

Open the catalog to page 1
CAMSIZER XT - 2

PARTICLE ANALYZER CAMSIZER XT Precise measurement of particle size and shape with the CAMSIZER XT n Measuring range from 1 μm to 3 mm without hardware adjustment n High resolution for narrow, mono-modal distributions n Excellent dynamic measurement range for broad distributions or multi-modal samples n Reliable detection of smallest amounts (< 0.1 %) of “oversize” particles n Particle shape analysis (e. g. aspect ratio, symmetry or roundness for detection of agglomerates, broken particles or contaminations)

Open the catalog to page 2
CAMSIZER XT - 3

eos at Product vid nology.com ch te w w w.ret sc Particle Analyzer CAMSIZER XT Measuring range from 1 µm to 3 mm – Measurement principle 5 – Modular design for optimum measurement conditions 6–7 – Air pressure dispersion Module “X-Dry” with “X-Jet” 6 – Gravity dispersion Module “X-Dry” with “X-Fall” 7 – Wet dispersion Module “X-Flow” 7 – Key features 8 – 11 – Comparison of measurement techniques 11 – Accessories 12 – Specifications 12 Experts for Particle Measurement Technology Retsch Technology's core competence is to combine innovative technology for particle characterization and quality...

Open the catalog to page 3
CAMSIZER XT - 4

PARTICLE ANALYZER CAMSIZER XT The Particle Analyzer CAMSIZER XT Benefits at a glance n Digital image processing with patented two-camera system (according to ISO 13322-2) n Wide dynamic measuring range from 1 μm to 3 mm n State-of-the-art optical system with ultra-strong LEDs for highest resolution and excellent depth of focus n Reliable detection of smallest amounts of “undersize” and “oversize” particles n Particle shape analysis (e. g. aspect ratio, symmetry or roundness for detection of agglomerates, broken particles and contaminations) n Very short measurement time of 1 – 3 minutes n...

Open the catalog to page 4
CAMSIZER XT - 5

PARTICLE ANALYZER CAMSIZER XT Certified calibration standard Recalibrating the CAMSIZER XT is a matter of seconds with the help of a highly precise (±0,1 µm) reference object, made by electron beam lithography, which simulates differently sized particles. This allows fully traceable and verifyable calibration and calibration status recording. The patented measurement principle sample flow basic camera zoom camera The patented measurement principle is fairly simple: Dispersed particles pass in front of two bright, pulsed LED light sources. The shadows of the particles are captured with two...

Open the catalog to page 5
CAMSIZER XT - 6

PARTICLE ANALYZER CAMSIZER XT Modular design for optimum measurement conditions Air pressure dispersion Gravity dispersion Wet dispersion Basic instrument The CAMSIZER XT’s “X-Change” system offers three alternative dispersion methods, allowing the selection of the optimum method for each sample type. Plug-in cartridge Measurement system X-Jet Air pressure dispersion X-Dry The modules/plug-in cartridges are easily exchanged in one minute allowing for a comfortable switching between dispersion methods. Watch the video on www.retschtechnology.com/camsizerxt to see how easily the “X-Change”...

Open the catalog to page 6
CAMSIZER XT - 7

PARTICLE ANALYZER CAMSIZER XT Gravity Dispersion with “X-Fall” Measuring range from 10 µm to 3 mm feed hopper gravity plug-in cartridge feed chute Pourable, not agglomerated samples can be analyzed by using the “X-Fall” plug-in cartridge. In this mode the particles fall from the chute through the field of view of the two cameras accelerated by gravity. Thanks to the comparably low speed of the particles, the large field of view and the high frame rate, the detection efficiency is very high, even for large particles of e. g. 3 mm. Only a few coarser particles in the sample are sufficient for...

Open the catalog to page 7
CAMSIZER XT - 8

PARTICLE ANALYZER CAMSIZER XT Wide dynamic measurement range Q3 [%] 100 90 80 70 60 50 40 30 20 10 0 X-Dry with X-Jet Example: Coffee Thanks to the patented two-camera principle, the CAMSIZER XT offers excellent resolution for fine particles as well as outstanding statistics for large particles which is crucially important for the detection of small amounts of oversized particles. The graphic shows a comparison between three differently ground coffee powder samples. The red curve represents a narrow size distribution while the green curve shows a much larger amount of over- and undersized...

Open the catalog to page 8
CAMSIZER XT - 9

Particle shape analysis Example: Catalysts Non-spherical, broken catalyst balls can be detected by looking at parameters like the aspect ratio (width divided by length of each particle, b/l) or the symmetry. The graphic shows a series of measurements with increasing amounts of broken particles. The original material is almost perfectly round, with b/l values above 0.95 (red curve). After each treatment with ultrasound the amount of broken particles increases. The amount of broken particles can be derived directly from the graph at the threshold value of b/l equal 0.95. A picture of the...

Open the catalog to page 9
CAMSIZER XT - 10

PARTICLE ANALYZER CAMSIZER XT Reliable detection of oversized particles X-Dry with X-Jet Example: PMMA micro beads Relative frequency Particle size The CAMSIZER XT features the latest camera technology with high frame rates and high resolution 16-bit grayscale images, to detect as many particles as possible in the shortest time. The graphic shows the comparison of two samples with different amounts of oversized particles. Sample 2 (red) contains more oversized particles at 20 microns than sample 1 (0.2%). The detection efficiency for small amounts of oversized particles is much better with...

Open the catalog to page 10
CAMSIZER XT - 11

PARTICLE ANALYZER CAMSIZER XT Sieving, Laser Diffraction or Dynamic Image Processing? A comparison of measurement techniques Performance Features Laser Diffraction Wide dynamic measurement range High resolution for narrow distributions Particle shape analysis Direct measurement technique Compatibility of results with other techniques Reliable detection of oversized grains Robust hardware, easy operation for routine analysis Analysis of individual particles High measurement speed, short measur

Open the catalog to page 11

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. Duetta

    8 Pages

  9. MacroRAM

    2 Pages

  10. PSA300

    5 Pages

  11. SZ-100

    4 Pages

  12. XPLORER-NS

    6 Pages

  13. EMIA series

    6 Pages

  14. GD PROFILER

    7 Pages

  15. XGT-7200

    2 Pages

  16. EMGA-921

    4 Pages

  17. EMGA-920

    4 Pages

  18. EMGA-930

    4 Pages

  19. EMIA-V2

    14 Pages

  20. VS-20

    6 Pages

  21. CLUE Series

    6 Pages

  22. XploRA One

    2 Pages

  23. Model H1034B

    2 Pages

  24. VS20

    6 Pages

  25. Forensics

    2 Pages

  26. OpenPlex

    2 Pages

  27. AFM Raman

    2 Pages

  28. MESA-50

    2 Pages

  29. Dual-FL

    7 Pages

  30. Aqualog

    6 Pages

  31. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages