XploRA SeriesSimply Better Raman Chemical Analysis & Imaging for Research & Industry Explore the future Automotive Test Systems I Process & Environmental I Medical I Semiconductor I Scientific HORIBA
Open the catalog to page 1Advantages • Non-destructive • Non-contact/In-situ sampling • Reduced sample preparation • Water/aqueous phase sampling • Organic/inorganic molecules • Amorphous/crystalline The sensitivity, spectroscopic and imaging performance of the XploRA product line enables the broadest range of sample analysis. Raman is an ideal technique for research and industry offering high quality data, reliability, versatility and improved value for money over other analytical techniques. Benefits not only include the range of samples that are suitable for analysis, but also the information content that is...
Open the catalog to page 2XploRA Series XploRA PLUS: Research Raman imaging has never been so fast! The XploRA PLUS incorporates unique and powerful functions in a reliable, high performance system, ideally suited to the research and analytical lab. It is fully confocal, not compromising image quality, spatial or depth resolution. The SWIFT™ Fast Raman images are the fastest fully confocal Raman images available, typically 10x faster than conventional Raman imaging. The simplicity and power of the XploRA PLUS is unmatched with an enhanced range of options such as multiple laser wavelengths, EMCCD detection, Raman...
Open the catalog to page 3The XploRA Innovation provides improved productivity and extended reliability. Improved Detection and Sensitivity • Superior CCD and EMCCD for Class leading S:N • asier and faster analysis E • Requiring far less laser power on the sample, preserving sample integrity • Ability to detect thin films, small particles, and dilute solutions Silicon (Si) 4th order sensitivity • Suitable for all laser wavelengths • Scaleable to large area and micron scale imaging for maximum image detail • Means faster and more reliable Raman imaging at the click of a button Raman Imaging just got Faster & Easier...
Open the catalog to page 4At a Glance Technical design offers automation and class leading ease of operation. Full Optical Microscopy To See Your Sample Extended polarized light microscope image • All modes of microscopy, transmission and reflection illumination • Options for DIC, phase, epifluorescence, dark field and polarized light microscopy • Automated Extended Video Montage • Range of options such as Autofocus, and ParticleFinder (auto‑location) will never limit the scope of the optical microscopy Maximum Detail, Resolution and Range • Optimized range and resolution in one-shot for all lasers • Full range...
Open the catalog to page 5Raman Data in Seconds: For Industrial Quality Control, Research and Analytical Testing The XploRA Series offers full spectral analysis in OneClick Operation. Simple operation, speed, low maintenance and push button results enables you to optimize productivity and efficiency. The XploRA Series is driven by LabSpec's intuitive user interface enabling logical workflow through an experiment. • HORIBA OneClick Raman operation • Autocalibration • Enhanced multi-page analysis reports • Augmented help and troubleshooting Sample methods for routine repetition User login accounts for system...
Open the catalog to page 6Simplified Workflow With Auto-Calibration OneCheck Simplified Calibration and Validation The patented calibration objective tool uses a certified reference material and ASTM method for system validation and ensures fast, easy calibration and validation of the instrument. OneCheck and the system is ready to run. Input Sample No preparation Impressively fast start-up time, less than 10 minutes from cold, removes the need for any lengthy start‑up procedures, adjustment or the need for the system to be continually powered on. Ideal for laboratory efficiency, running costs and the environment!...
Open the catalog to page 7Bio/Life science Nano Raman XploRA™ PLUS Faster Raman SWIFT™ Imaging / SWIFTXS (with EMCCD) Confocal Imaging Routine operation Automation YES with XY stage Optional DuoScan™ imaging YES Optional XY stage & DuoScan™ depending upon version OneClick Auto/Raw OneClick Auto 0.5 gm XY 10 nm* with TERS Integrated AFM Raman software Full Microscope Upright and/or inverted Standard + High > 1.4 cm-1 FWHM Standard + High > 1.4 cm-1 FWHM Standard + High > 1.4 cm-1 FWHM Multi-laser Options * Requires HORIBA TERS tips XploRA Nano • AFM Raman module • XploRA PLUS and INV versions • TERS Ready: 10 nm...
Open the catalog to page 8All HORIBA Process & Environmental catalogs and technical brochures
-
SLFA-60.6000 catalog
4 Pages
-
EMIA Series catalog
6 Pages
-
EMIA-STEP catalog
2 Pages
-
EMGA-921 catalog
4 Pages
-
Ultima Expert LT
4 Pages
-
LA-350
4 Pages
-
LA-960
10 Pages
-
HT-110_TOC
2 Pages
-
XGT-7200 catalog
8 Pages
-
LAQUAtwin
6 Pages
-
LAQUA series
20 Pages
-
CODA-500
1 Pages
-
51 series
2 Pages
-
VA-5000 Analyzer
1 Pages
-
B-340 series
2 Pages
-
SEC-Z500X series
13 Pages
-
Water quality analyzer
12 Pages
-
Compact Water Quality Meter
11 Pages
-
IG Series
4 Pages
-
TW-100
4 Pages
-
INM-700
4 Pages
-
ENDA-4000
2 Pages
-
GA-360E Series
2 Pages
-
PA-1000
2 Pages
-
IG-410
2 Pages
-
Infrared Thermometers
8 Pages
-
Conductivity/Resistivity Meters
16 Pages
-
U-50 Series
8 Pages
-
VA-3000 Series
10 Pages
-
XE multi-gas CEMS
2 Pages
-
AP-370 Series
12 Pages
Archived catalogs
-
B-700series
5 Pages