X-RAY ANALYTICAL MICROSCOPE

Open the catalog to page 1
XGT-7200 catalog - 2

XGT-7200V — A system for every application The XGT-7200V X-ray fluorescence (XRF) microscope combines optical visualization with high performance elemental analysis and imaging. No sample pre-treatment is necessary-simply insert the sample, and within three mouse clicks the analysis can be started. Dual Vacuum modes ensure the highest sensitivity to light elements (Full Vacuum) or atmospheric pressure analysis for fragile/biological materials (Localised Vacuum). Intuitive software guides the user through every step-from initial sample set up through to comprehensive data analysis...

Open the catalog to page 2
XGT-7200 catalog - 3

X-RAY ANALYTICAL MICROSCOPE XGT 7200V The spacious sample chamber allows samples of all shapes and sizes to be accommodated. The integrated XYZ stage ensures easy handling. Within seconds the user can switch between the Dual Vacuum modes available within the sample chamber. These allow chamber conditions (and measurement results) to be optimised for different samples. Full Vacuum switch I ' Full vacuum offers the highest sensitivity to light elements. Vacuum Atmospheric Pressure Sample: Silica glass Software The XGT-7200V is operated via intuitive software which leads the user through...

Open the catalog to page 3
XGT-7200 catalog - 4

Mono-cap ^ Failure analysis Complete acquisition options Full data analysis capabilities A comprehensive software platform Easy operation An intuitive navigator window leads the user through the experiment, from sample set up, through acquisition, to complete data analysis. The XGT-7200V offers the user a wide choice of acquisition methods. • Single point analysis • Multi-point analysis •Automated multi-point analysis with coordinate file import • Hyperspectral elemental imaging •Transmission X-ray imaging Hyperspectral imaging A full spectrum is acquired at each and every pixel of the...

Open the catalog to page 4
XGT-7200 catalog - 5

ious sample chamber The spacious sample chamber allows samples of all shapes and sizes to be accommodated. The integrated XYZ stage ensures easy handling. The user has complete control over sample movement and the analysis position via three integrated colour video cameras. pillary The HORIBA X-ray Guide Tube (XGT) provides X-ray beams with high intensity and microscopic diameters - ranging from 1.2 mm down to a unique 10 μm. They allow fast and easy elemental analysis of individual particles and features. The exclusive use of mono-capillary optics in the XGT-7200V ensures analytical...

Open the catalog to page 5
XGT-7200 catalog - 6

The Dual Vacuum modes of the XGT-7200V offer the user versatility for a wide range of samples. Even samples which cannot withstand full vacuum conditions can be analysed by using the Localised Vacuum mode, which retains the sample at atmospheric pressure. Fast switching * Application The Full Vacuum mode offers the highest sensitivity to light elements. It provides optimised analysis conditions for pharmaceutical tablets, mineral sections and light element alloys. Application Clam With the Localised Vacuum mode it is possible to analyse biological materials and other samples which cannot be...

Open the catalog to page 6
XGT-7200 catalog - 7

Application Focus The software controlled sample stage allows the user to define a number of experiments, including multi-point, line, and grid analyses. A maximum of 1000 points can be specified for multi-point analysis. Once the points are defined on the whole sample image and/or the high magnification image the spectra are automatically collected. FORENSIC SCIENCE Forensic scientists generally require fast and non-destructive analysis of a very wide range of materials. Often these materials are presented in very small quantity, as evidence collected from a crime scene. The elemental...

Open the catalog to page 7
XGT-7200 catalog - 8

■Specification of XGT-7200V Principle Detection range Sample type Fluorescence X-ray detector Transmission X-ray detector X-ray tube X-ray guide tube Sample chamber size Atmosphere Sample size Sample stage Optical image Data acquisition Qualitative analysis Quantitative analysis Mapping Date management Power supply Power consumption Operation Instrument weight Outer dimensions Energy dispersive X-ray fluorescence spectrometry Sodium (11 Na) to Uranium (92U) Solid, Liquid, Powder SDD (LN2 Free) Nal(TI) scintillator Rh target Tube voltage: 15/30/50 kV Tube current: Max 1.0 mA Dual-tube...

Open the catalog to page 8

All HORIBA Process & Environmental catalogs and technical brochures

  1. LA-350

    4 Pages

  2. LA-960

    10 Pages

  3. HT-110_TOC

    2 Pages

  4. LAQUAtwin

    6 Pages

  5. LAQUA series

    20 Pages

  6. CODA-500

    1 Pages

  7. 51 series

    2 Pages

  8. B-340 series

    2 Pages

  9. IG Series

    4 Pages

  10. TW-100

    4 Pages

  11. INM-700

    4 Pages

  12. ENDA-4000

    2 Pages

  13. PA-1000

    2 Pages

  14. IG-410

    2 Pages

  15. U-50 Series

    8 Pages

  16. VA-3000 Series

    10 Pages

  17. AP-370 Series

    12 Pages

Archived catalogs

  1. B-700series

    5 Pages