Catalog excerpts
WATER QUALITY ANALYZERS pH mV(ORP) ION SENSOR TECHNOLOGY Conductivity DO Resistivity Salinity TDS
Open the catalog to page 1ELECTRODE LINE UP HORIBA popular electrode is now even tougher and responds faster Enhanced stability and minimized drift Integrating two new technologies for faster response times and optimal performance pH fast response glass membrane (Patent pending) The membrane contains HORIBA's unique combination of rare earth metals to improve response time by twofold and to increase durability against chemical substances. Response data from switching pH4 standard solution to tap water. New electrode Conventional stability point electrode stability point Conventional electrode water proof water...
Open the catalog to page 2Not just “unbreakable” . New flat sensor innovations allow the measurement of trace sample droplets or the measurement of solid sample surface. What is an ISFET (semiconductor sensor) ? ISFET is the abbreviation of Ion Sensitive Field Effect Transistor. The response membrane is equipped with semiconductor based sensor. Special features of the ISFET The flat electrode has less than a 100μm distance between the housing and the sensor water proof water proof water proof water proof ater, food, 1. Will not crack or break like conventional glass electrodes 2. The sensor is flat and very small in...
Open the catalog to page 3Intuitive and very easy to use touch panel operation Simply slide your finger across the screen to switch displays 2-channel can be displayed simultaneously Color LCD display NAVI COND RESI COND RESI
Open the catalog to page 4Full support for on-screen settings confirmation, maintenance information and troubleshooting tips guide you through trouble free operation Inspection Navigation_ Easy navigation for main unit and electrode Various industrial standards (JIS, USP, EP, JP, CP) Troubleshooting Navigation On-screen reliable support for a resolution when a problem occurs during calibration or sample measurements. A user's guide is incorporated in the software to access if one experiences any operation difficulties. Liquid JuMMtfi 11 t «r*tl£ ftt Hbtml 1« in It* flunrttr »m tlnsntft hs diMp. Application...
Open the catalog to page 5Economical meter for pH and temperature Multi-parameter for pH/temperature/ORP with PC/printer output capability. Multi-parameter for pH/temperature/ORP/ION with PC/printer output capability
Open the catalog to page 6Multi-parameter for pH/temperature/ORP/ conductivity with PC/printer output capability Multi-parameter for pH/temperature/ORP/ dissolved oxygen with PC/printer output capability Portable conductivity/resistivity/ salinity meter with PC/printer output Portable dissolved oxygen meter with PC/printer output Set includes conductivity electrode. (model 9382-10D) Select from the followings. • 2 m cable (OM-51-2) • 10 m cable (OM-51-10) • Laboratory (OM-51-L1) (BOD measurement) Revolutionary waterproof meter and electrodes enhance care-free operation in the lab or eld pH electrode (model 9621-10D)...
Open the catalog to page 7F-70 series / DS-70 series Specifications Measurement pH method ION Conductivity Salinity Resistivity TDS Measurement pH range COND RESI COND RESI Glass electrode method Ion electrode method mV(ORP) Temperature(Display) ION Conductvity 2 AC bipolar method Conversion from conductivity value Conversion from conductivity value Conversion from conductivity value pH0.000 ~ 14.000 Resolution 0.001pH pH0.000 ~ 14.000 Resolution 0.01/0.001pH ±1999.9mV Resolution 0.1mV 0.0 ~ 100.0℃(-30.0 ~ 130.0℃) Resolution 0.1℃ 0.00μg/L ~ 999g/L(mol/L) Resolution Valid numbers 3 digits Cell constant...
Open the catalog to page 8pH/ORP Electrode Line up 2 AC bipolar method Conversion from conductivity value Conversion from conductivity value Conversion from conductivity value 0.0 ~ 100.0℃(-30.0 ~ 130.0℃) Resolution 0.1℃ Cell constant 100m-10.000mS/m ~ 19.99S/m Cell constant 10m-10.0μS/m ~ 1.999S/m Cell constant 1000m-10.00mS/m ~ 199.9S/m Resolution 0.05% of F.S. 0.00 80.00PPT(0.000% 8.000%) Resolution 0.01PPT(0.001%) ~ 199.9kΩm Cell constant 100m-10.00Ωm Cell constant 10m-10.0Ωm ~ 1.999MΩm Cell constant 1000m-10.000Ωm ~ 19.99kΩm Resolution 0.05% of F.S. 0.01 mg/L ~ 100 g/L 0.01 mg/L ~ 1000 g/L Resolution 0.01mg/L...
Open the catalog to page 9Water proof Accurate measurement from only a single drop on the HORIBA original flat sensor. LAQUAtwin's easy, reliable and on-site quick measurement quick measurement of 7 parameters brings a new dimension to your water quality testing. Unique measurement variation by LAQUAtwin. Select measurement method depending on your situation and sample. Conductivity(EC) Meter Drop a sample with a pipette, small volume as 0.1mL can be measured. Using sampling sheet B (optional), volumes down to 0.05 mL can be tested. When you're in the lab, you can test the sample in a beaker. Ensure the sensor guard...
Open the catalog to page 10g sheet ace e r e off f the mpling d with nd Accurate reading from only a single drop, in a few seconds. whenever and wherever you want to measure without beakers. It is your "lab-in-a-pocket". pH, conductivity, ions and Salt concentration. 7 parameters, 11 models Calibrate and measure at the touch of a button the smiley face will tell you when the result can be read LAQUAtwin is fully waterproof and dustproof(IP67) Carrying case containing standard solution comes standard for handy lab portability Solid samples Foods containing some moisture can be tested by placing a small piece directly...
Open the catalog to page 11WATER QUALITY ANALYZERS website Horiba 60 years engineering realizes lineup various of water quality analyzers and electrodes for any laboratory use. "Water quality analyzer website" introduces HORIBA lab water quality analyzers and electrodes and provide many services such as manual download or water quality measurement tips. LAQUA website Taking your comments and feedback to our heart,"LAQUA" is our new brand to deliver you our best solution to your needs. "LAQUA" website introduces case of solutions with LAQUA and innovative pH electrodes. Water quality will be more familiar with you by...
Open the catalog to page 12All HORIBA Process & Environmental catalogs and technical brochures
-
SLFA-60.6000 catalog
4 Pages
-
EMIA Series catalog
6 Pages
-
EMIA-STEP catalog
2 Pages
-
EMGA-921 catalog
4 Pages
-
Ultima Expert LT
4 Pages
-
LA-350
4 Pages
-
LA-960
10 Pages
-
HT-110_TOC
2 Pages
-
XGT-7200 catalog
8 Pages
-
LAQUAtwin
6 Pages
-
LAQUA series
20 Pages
-
CODA-500
1 Pages
-
51 series
2 Pages
-
VA-5000 Analyzer
1 Pages
-
B-340 series
2 Pages
-
SEC-Z500X series
13 Pages
-
Compact Water Quality Meter
11 Pages
-
IG Series
4 Pages
-
TW-100
4 Pages
-
INM-700
4 Pages
-
ENDA-4000
2 Pages
-
GA-360E Series
2 Pages
-
PA-1000
2 Pages
-
IG-410
2 Pages
-
Infrared Thermometers
8 Pages
-
Conductivity/Resistivity Meters
16 Pages
-
U-50 Series
8 Pages
-
VA-3000 Series
10 Pages
-
XE multi-gas CEMS
2 Pages
-
AP-370 Series
12 Pages
Archived catalogs
-
B-700series
5 Pages