Catalog excerpts
HORIBA proudly introduces the newest breakthrough in particle size technology. ‘ . . ' - ' . J tr W This latest evolution in the LA series advances scientific knowledge for tomorrow's world through intuitive software, unique accessories, and high performance. The LA-960 continues HORIBA's proud tradition of leading the industry with innovative design.
Open the catalog to page 2HORIBA’s Original Optical DesignHORIBA's ground breaking optical design perfects the static light scattering particle sizing technique. Advanced Detector Design The number of detectors, angular range, and layout each contribute to overall system performance. The LA-960 uses 87 logarithmically spaced silicon photodiode detectors covering a range of 0.006 -165.7 degrees to measure complete particle size distributions. Superior Instrument-to-Instrument Precision The LA-960 is designed and built to provide the same experience regardless of manufacture date, operator skill, or geographic...
Open the catalog to page 4State of the Art Sampling Systems Auto-fill Circulation Flow cell The LA-960 Powderjet combines several unique and patented features to provide the most reproducible dry measurements. Use the Auto Measurement function to control vacuum, air pressure, powder flow, start/stop conditions, measurement duration, and data processing. Designed to handle every application including small sample amounts, friable powders, and highly agglomerated materials. Wet Measurement Sample-to-sample analysis in less than 6,0 seconds The HORIBA LA-960 wet circulation system is an easy, fast and very...
Open the catalog to page 5Powderjet Dry Feeder Accessory Laser scattering particle size distribution analyzer Model: LA-960 Measurement Principle ^Windows is a registered trademark of Microsoft Corporation in the United States and other countries. 5^ When ordering the Powderjet please specify the power requirements for the final destination. ^ Above specifications and functionality are valid only when Powderjet is installed on the LA-960 main unit and controlled using the LA-960 software. ^Manufacturers and models indicated for vacuum, air compressor, computer, monitor, and/or printer are subject to change. ©Air...
Open the catalog to page 6Functional polymers The size of particles greatly influences several factors such as dissolution rate, dosing, bioavailability, and immunotoxic-ity, making it an essential parameter for pharmaceutical and biotechnology applications. From simple inhalers to advanced chemotherapies, particle size affects treatment efficacy. The performance of plastics, such as PET is determined by the molecular weight (i.e., size) of the polymers used to prepare the material. The same sort of analysis is also critical for sealants and adhesives. Particle size influences both capacity and coulombic efficiency...
Open the catalog to page 7State of the art nanoparticle measurement Measurement range 10 nm - 5,000 um The LA-960 features a wide measurement range to measure every application. The unique optical bench is user-friendly and standard in every LA-960 configuration. The advanced design of the LA-960 allows for easy measurement of nanoparticle applications. NIST-traceable size standards verify that the LA-960 accurately measures peaks as fine as 30 nanometers. 60 - second measurement cycle, even in wet mode This incredible speed is made possible by automatic laser alignment, fully automated liquid handling, and...
Open the catalog to page 8HORIBA Vietnam ORIB OR tna na a Company Limited ompany Limited pan imited mt HORIBA Jobin Yvon GmbH mbH b Head Office HORIBA TAL Sr HO IBA ITALIA S l Mi n Milano Milano Office HORIBA In ia R India Privat td Private Ltd. v t Bangalore Office Off ce HORIBA (Thailand) Ltd. BA East Office s st HORIBA Korea Ltd. Seoul Branch HORIBA Instruments Inc. Edison office Guangzhou B a uangzh Branch Bran Head Office Beijing Branch HORIBA Instruments Inc. A Edison Ltda. Brasil, office The HORIBA Group adopts IMS (Integrated Management System) which integrates Quality Management System ISO9001,...
Open the catalog to page 9HORIBA Scientific Automotive Test Systems I Process & Environmental I Medical I Semiconductor I Scientific
Open the catalog to page 10All HORIBA Process & Environmental catalogs and technical brochures
-
SLFA-60.6000 catalog
4 Pages
-
EMIA Series catalog
6 Pages
-
EMIA-STEP catalog
2 Pages
-
EMGA-921 catalog
4 Pages
-
Ultima Expert LT
4 Pages
-
LA-350
4 Pages
-
HT-110_TOC
2 Pages
-
XGT-7200 catalog
8 Pages
-
LAQUAtwin
6 Pages
-
LAQUA series
20 Pages
-
CODA-500
1 Pages
-
51 series
2 Pages
-
VA-5000 Analyzer
1 Pages
-
B-340 series
2 Pages
-
SEC-Z500X series
13 Pages
-
Water quality analyzer
12 Pages
-
Compact Water Quality Meter
11 Pages
-
IG Series
4 Pages
-
TW-100
4 Pages
-
INM-700
4 Pages
-
ENDA-4000
2 Pages
-
GA-360E Series
2 Pages
-
PA-1000
2 Pages
-
IG-410
2 Pages
-
Infrared Thermometers
8 Pages
-
Conductivity/Resistivity Meters
16 Pages
-
U-50 Series
8 Pages
-
VA-3000 Series
10 Pages
-
XE multi-gas CEMS
2 Pages
-
AP-370 Series
12 Pages
Archived catalogs
-
B-700series
5 Pages