Infrared Thermometers

Infrared Thermometers

Infrared Thermometers

Product catalog summary

Overview

The HORIBA IT-540 and IT-550 series are handheld, non-contact infrared thermometers designed for quick, accurate, and easy temperature measurements across a wide range of applications. These devices offer reliable functionality, narrow focus, splash resistance, and cost-effective performance tailored to various industrial and laboratory needs.

Product Lineup and Features

The series includes multiple models with varying features:

  • IT-550 Series: Equipped with twin laser sights for precise targeting, available in Field (F), Laboratory (L), and Spot (S) models. These models support digital and analog outputs, memory functions, and printer connectivity via an optional expansion kit.
  • IT-540 Series: Compact and lightweight with standard, narrow-focus, and spot-focus models. Features include upper/lower temperature alarms, measurement-hold functions, twin or single beam markers, and LED target markers.

All models cover temperature ranges from -50°C to 500°C, with some IT-540 variants extending up to 1000°C.

Key Specifications and Functionalities

  • -50°C to 500°C (standard), up to 1000°C for select models.
  • Targeting: Twin laser beams for precise aiming (IT-550 series), single beam or LED markers (IT-540 series).
  • Output Options: Analog output, digital output, voltage output depending on model.
  • Data Handling: Memory function, measurement hold, upper/lower temperature alarms, and printer output capabilities.
  • Durability: Splash-resistant design suitable for wet environments, especially beneficial in food industry applications.
  • Display: Resolution switch available on select models for enhanced readability.

Applications

The thermometers are suitable for diverse fields including:

  • Electronic components temperature measurement (e.g., IC components)
  • Food industry (HACCP compliance, kitchen environments)
  • Maintenance and safety inspections (e.g., elevator machine rooms, piping)
  • Construction and civil engineering (thermal insulation, ovens, dryers)
  • Laboratory testing and field measurements

Data Management and Connectivity

The IT-550 series supports advanced data processing features:

  • Optional expansion kit enables direct connection to printers for hardcopy output.
  • Digital and voltage outputs allow easy integration with computers and recorders for data export to spreadsheets or word processors.
  • Memory functions facilitate collection and storage of temperature data for later analysis.

Design and Usability

  • Compact, lightweight, and handheld design for portability.
  • Splash-resistant construction allows safe operation with wet hands.
  • Twin laser sights reduce required target area to one-third compared to older models, enabling accurate measurement of small objects from a distance.
  • Audio alarms and flashing markers alert users to abnormal temperature readings.

Safety and Compliance

Users are advised to read the operation manual thoroughly to ensure safe and proper handling. The devices comply with HACCP standards, making them suitable for food safety applications.

Manufacturer and Support

HORIBA Ltd. provides global support with offices and representatives in Japan, Korea, Taiwan, China, and the USA. Contact information and website details are provided for customer assistance.

See more

Catalog excerpts

Infrared Thermometers-1

Process & Environmental Infrared Thermometer Handheld Models

 Open the catalog to page 1
Infrared Thermometers-2

Infrared Thermometer Handheld Models Quick, Accurate and Easy A full lineup of hand-held infrared thermometers covering a wide range Every unit offers reliable functionality, narrow focus, splash resistance and low cost exceptional performance. HORIBA has the ideal model to meet your specific temperature measurement needs. Narrow-focus model Printer I Splash- I Memory output I resistant I function (Option) (Option) (Option) (Option) Analog I Splash- I Dis.P'?y Twin |Upper/Lower| Measurement- beam I temp I hold marker I alarm I function Twin |Upper/Lower| Measurement- beam I temp I hold marker...

 Open the catalog to page 2
Infrared Thermometers-3

(Unit: mm) ¿20 ¿24 ¿48 ¿80 500 1000 1500 2000 ¿40 ¿72 500 HACCPCompliance 1000 Food temperature management Non-contact testing of highvoltage equipment such as a power supply system ¿40 500 ¿72 1000 ¿100 Temperature measurement as a Surface temperature part of lab tests measurement of ICs and other minute surfaces 400 ¿100 400 HACCPCompliance ¿2.5 Refrigeration maintenance of Temperature check when foods adding or removing food from storage 73 ¿2.5 ¿32.4 30 100

 Open the catalog to page 3
Infrared Thermometers-4

Non-Contact Infrared Thermometer IT-550 Series CE marking compliant Narrow Focus, Splash-Resistance & Digital Output The Twin-Laser Sight Makes Measurements A Snap! Narrow-focus type Target area of ø24/1000 mm Digital Output Memory function, Digital Output, Voltage Output, PC/Printer connection and more! Speedup data processing by collecting temperature measurements directly from the thermometer! (F and L models) The twin laser sight makes it easy to focus on target. The F (Field) model, L (Lab) model and the S (Spot) model all have unique twin-laser sights optimized for your applications. The...

 Open the catalog to page 4
Infrared Thermometers-5

( Graphing made easy ) C Obtaining hardcopy J ( Simplifying reports ) • Using the accompanied software (L & s models) ▲Sample screen • Exporting data to spreadsheets (an models) ▲Sample screen of MS Excel PRINT IglfftM ▲Sample printout ASample report ( Data manipulations J Using a graphical recorder J ▲Sample graph ▲Sample screen of MS Word Power supply minute devices For laboratory Use. Spot Focus Model output ^^^ffln (Option) (Option) Spectral response Measurement temp, range Display temp, range (Display resolution) Response time [0.1 *C resolution] Within ±1 'C (-50.0 to -0.1 'C), Within ±0.5'C...

 Open the catalog to page 5
Infrared Thermometers-6

Non-Contact infrared Thermometer The easy-to-carry, compact & lightweight design 3 Types of narrow field, low cost and spot focus advanced design • Quick, accurate readings, even under rapidly changing ambient temperatures minimizing "temperature drift." • Wide measurement area • Abnormal temperature warning by audio alarm and flashing marker* * Only for models designated NH and N. For routine maintenance work Narrow-focus model (Dual beam model) For measuring electronic components For measuring foods, etc Spot focus model Standard model Narrow-focus model Upper/Lower! Measurement- Spot focus...

 Open the catalog to page 6
Infrared Thermometers-7

Infrared Thermometer ELECTRIC / ELECTRONIC during regular 'Electronic components Check for abnormal heating Spot infrared thermometers measure temperatures of very small parts. SAFETY / MAINTENANCE Check for overheating or freezing. Infrared thermometers can inspect different points i Elevator machine room Overheating inspection of the operator motor and other parts during regular Temperature control in baking and other process is crucial. Non-contact measurement is sanitary and leads CONSTRUCTION / CIVIL ENGINEERING ^Thermal insulation

 Open the catalog to page 7
Infrared Thermometers-8

+ Support System Covering HORIBA INSTRUMENTS LIMITED OFFICE. China HORIBA INSTRUMENTS Tokyo Sales Office TAIWAN Representative Office OFFICE, China HORIBA INSTRUMENTS HORIBA continues contributing to the preservation of the global environment through analysis and measuring technology. Please read the operation manual before using this product to assure safe and proper handling of the product. •The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. •The color of the actual products may differ from the color pictured in this...

 Open the catalog to page 8

Archived catalogs

  1. B-700series

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.