AP-370 Series
12Pages

{{requestButtons}}

Catalog excerpts

AP-370 Series - 2

These highly sensitive E give precise, reliable me I Selective data output I Storing data in memory Troublesome calibration procedures have been reduced to the push of a function key. At the Auto-Interval Calibration (AIC) menu you can set the start time, the start range, and the interval for the automatic calibration. The system clock and calendar then assure that your calibration instructions are executed precisely. To make things even easier, remote auto-calibration can also be done from your own computer, via the monitor's RS-232C serial port (optional). An auto-range function that...

Open the catalog to page 2
AP-370 Series - 3

ambient air pollution monitors I Memory card for data management (oPt I Readout view, concentration and mass display with touch panel screen. I Minimal influence from interference components and ambient temperature I At last—a small, compact system An aval lable CompactFlash®(CF) can save average or integrated value, and read and collect data for off-line With the CF it is possible to conveniently use the analyzer The front panel can display the readout all that is needed (Not available on Model APHA-370, where CH4 values are displayed as ppm, NMHC and THC as ppmC.) Automatic compensation...

Open the catalog to page 3
AP-370 Series - 4

According to EN14626 and VDI 4202/4203 TUEV Bericht 936/21204643B 05. Jan. 2006 U. S. EPA REFERENCE Equivalent Number RFCA-0506-158 The cross flow modulation type, infrared-absorption technology eliminates the need for adjusting optical alignment. For the user, this means very stable and sensitive (5 ppm F.S.) measurements. The APMA-370 uses an AS type (antishock) interference-compensating detector, and a purified reference gas. The reference gas is generated by purging the sample through an oxidation process, where an oxidizing catalyst burns the CO to CO2. These features eliminate...

Open the catalog to page 4
AP-370 Series - 5

TUEV Bericht 936/21204643D 07. Jul. 2006 U. S. EPA REFERENCE Equivalent Number EQSA-0506-159 The APSA-370 uses an innovative detector and a new optical system for low background, high sensitivity (0.05 ppm F.S.), and greatly improved stability. The fluorescent chamber design gives measurements with minimum influence from moisture. The unit has built-in aromatic hydrocarbon cutter with a selective transmission membrane. This reduces the influence of interference components. Coupled with Horiba's unique flow-path, it also makes it possible to extend the working life of the cutter and to take...

Open the catalog to page 5
AP-370 Series - 6

According to EN14211 and VDI 4202/4203 TUEV Bericht 936/21204643C 07. Jul. 2006 U. S. EPA REFERENCE Equivalent Number RFNA-0506-157 The APNA-370 uses a combination of the dual cross flow modulation type chemiluminescence principle and the referential calculation method. This gives it the advantages of the single-detector method plus the ability to do continuous measurements of NOx, NO, and NO2. The design gives great stability and extremely high sensitivity (0.1 ppm F.S.) Standard equipment includes a drier unit with an automatic recycle function to provide dry ambient air as the ozone...

Open the catalog to page 6
AP-370 Series - 7

The APHA-370 uses a combination of the flame ionization detection method and selective-combustion. This gives it the advantage of the single-detector method plus the ability to perform continuous measurements, free of zero-drift, for THC, NMHC, and CH4. The design gives great stability and high sensitivity (0-5 ppm F.S.) The APHA-370 has a relative-sensitivity correction function for CH4 and NMHC. All the necessary features are built right into a single rack-sized instrument, including a catalytic unit for selective combustion (i.e., an NMHC cutter); a catalytic unit for generating...

Open the catalog to page 7
AP-370 Series - 8

TUEV Bericht 936/21204643A 05. Jan. 2006 U. S. EPA REFERENCE Equivalent Number EQOA-0506-160 The APOA-370 uses the cross flow modulation type, ultra-violet absorption method in conjunction with the comparative calculation method. This permits continuous measurement with great stability and high sensitivity (0.1 ppm F.S.) Horiba's innovative heated deozonizer provides reference gas by decomposing the O3 found in the sample This has the advantages of (1) reducing the influence from interference, (2) making the monitor insensitive to great changes in moisture content, and (3) prolonging the...

Open the catalog to page 8
AP-370 Series - 9

Calibration Equipment Features 'Principle Combined use of the H2S converter unit and the APSA: SO2 Monitor makes H2S measurement possible. The H2S converter unit contains two types of catalyst: SOx scrubber and H2S converter. SOx is removed by the SOx scrubber, and then the H2S that has passed through is converted into SO2 by the H2S converter. This SO2 is then measured by the APSA: SO2 Monitor HORIBA offers various calibration products for optional use with the AP-370. HORIBA's calibration equipment support mainly the following methods: All calibrators can be equipped with thermal mass...

Open the catalog to page 9
AP-370 Series - 10

Intelligent Data Acquisition System HORIBA's IDA-2000 is an intelligent data acquisition system (DAS) using a desktop or industrial PC, designed for fully automatic monitoring stations. The entire data capture and mean value calculation as well as control of the analyzers is executed by 32 bit multitasking software, running in a state-of-the- art Windows environment. It combines the power of a workstation with the ease of use, compatibility and productivity of a personal computer. The measured values as well as operating and error status messages are gathered in a 5-second interval from the...

Open the catalog to page 10
AP-370 Series - 11

Complete Integrated System HORIBA designs, assembles, calibrates and tests complete integrated systems for simultaneously measuring multiple pollutants. A system for monitoring five pollutants can typically fit into one 19-inch rack. Rack-mounted systems can be installed in equipment rooms, stand-alone shelters, trailers, vans, large trucks, or aboard marine vessels. HORIBA can integrate products into existing monitoring systems, or design and build a new system. South african bureau of standards Various Types of Fixed Stations and Mobile Laboratories HORIBA designs and builds complete...

Open the catalog to page 11
AP-370 Series - 12

Each HORIBA AP-370 Series Monitor is packaged in a light metal enclosure with sliding chassis suitable for either a table-top set-up in a research laboratory or mounting on a standard 19-inch rack for permanent installation. All the controls and serviceable components are accessible from the front for easy maintenance while the plumbing and cable connections are neatly arranged at the back. Dimensional Outline Unit: mm HORIBA continues contributing environment through analysis Please read the operation manual before using this product to assure safe and proper handling of the product. •The...

Open the catalog to page 12

All HORIBA Process & Environmental catalogs and technical brochures

  1. LA-350

    4 Pages

  2. LA-960

    10 Pages

  3. HT-110_TOC

    2 Pages

  4. LAQUAtwin

    6 Pages

  5. LAQUA series

    20 Pages

  6. CODA-500

    1 Pages

  7. 51 series

    2 Pages

  8. B-340 series

    2 Pages

  9. IG Series

    4 Pages

  10. TW-100

    4 Pages

  11. INM-700

    4 Pages

  12. ENDA-4000

    2 Pages

  13. PA-1000

    2 Pages

  14. IG-410

    2 Pages

  15. U-50 Series

    8 Pages

  16. VA-3000 Series

    10 Pages

Archived catalogs

  1. B-700series

    5 Pages