Catalog excerpts

industrial & Commercial Thermal Solenoid valves for air VR Technical Information • GB 3 Edition 05.121 • Quick or slow opening and closing • Flow rate can be restricted • Robust design for a long service life • Suitable for high-duty cycling • Internal bypass orifice can be selected • EC type-tested and certified • Certified by Gosstandart pursuant to GOST-TR
Open the catalog to page 1
Solenoid valves for air VR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Examples of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.1 Solenoid valve for air VR..N,...
Open the catalog to page 2
VR..R..N quick opening/closing VG..R..R slow opening/closing VG..F..N quick opening/closing Robust solenoid valves for air VR for staged control of industrial burners in cold-air operating mode. For heavy duty use in industrial heat generation.
Open the catalog to page 3
Metallurgical industry: forging furnace Ceramics industry: intermittent shuttle kiln Aluminium industry: smelting furnace
Open the catalog to page 4
2 Certification EC type-tested and certified Meets the requirements of the – Low Voltage Directive (2006/95/EC), – EMC Directive (2004/108/EC). Approval for Russia Certified by Gosstandart pursuant to GOST-TR. Approved by Rostekhnadzor (RTN). Scan of the approval for Russia (RUS) – see www. docuthek.com ➔ Elster Kromschröder ➔ Products ➔ 03 Valves and butterfly valves ➔ Solenoid valves for air VR ➔ Kind of document: Certificate ➔ VG B00071 (nationales Zertifikat Russland) (RUS)
Open the catalog to page 5
3 Function 3.1 Solenoid valve for air VR..N, quick opening and closing Solenoid coil Iron core Closing spring Valve seat Valve disc Restrictor The solenoid valve for air VR is closed when de-energized. seat. The solenoid valve for air VR closes and the air supply is stopped. Opening: the applied AC voltage is rectified and generates a powerful magnetic field in the solenoid coil. The magnetic field attracts the iron core and lifts the valve disc from the valve seat, acting against the effective inlet pressure and the closing spring force. The solenoid valve for air VR opens and the air...
Open the catalog to page 6
3.2 Solenoid valve for air VR..R, slow opening and closing Ball Damping unit fully damped Start rate The solenoid valve for air VR..R opens and closes within 4 s. By turning the damping unit, the start rate can be set between 0 and 70% of the flow rate: The stem of the iron core is connected to the damping spindle via a ball. This connection ensures that the closing movement is damped. Turning it clockwise will decrease the start rate and turning it anti-clockwise will increase the start rate. 3.3 Solenoid valve for air VR..L, slow opening and quick closing The VR..L closes within 1 s. No...
Open the catalog to page 7
Flow rate 4.1 Bypass flow rate The solenoid valve for air VR is available with a bypass orifice in the valve housing on request. 50 The diameter of the bypass orifice depends on the supply pressure and air requirement. Inlet pressure pu [mbar]
Open the catalog to page 8
= standard = optional Order example VR 40R01NT33D10 Description Solenoid valve for air Nominal diameter Rp internal thread Flange to ISO 7005 pu max. 150 mbar Quick opening, quick closing Slow opening, quick closing Slow opening, slow closing Mains voltage 220/240 V AC, 50/60 Hz Mains voltage 120 V AC, 50/60 Hz Mains voltage 24 V DC Terminal connection box, IP 54 Electrical connection via standard socket
Open the catalog to page 9
Project planning information 6 Project planning information Wiring to EN 60204-1. Installation position: black solenoid actuator in the vertical upright position or tilted up to the horizontal, not upside down. The solenoid valve for air VR must not be in contact with masonry. Minimum clearance 20 mm. Do not store or install the unit in the open air. The solenoid body heats up during operation depending on ambient temperature and voltage.
Open the catalog to page 10
7 Accessories 7.1 Position indicator will have been burnt through. The switch can then only be operated at this power rating or higher power rating. Regardless of nominal diameter, the solenoid valve for air VR can be subsequently fitted with a micro switch for the “closed” or “not closed” signal, depending on the wiring of the contact sequence. Cable gland: PG 11, on request: with socket to ISO 4400. Connection ratings: 12 – 24 V AC/DC I = 0.1 A, cos ϕ = 1, I = 0.05 A, cos ϕ = 0.6. 250 V AC I = 1 A, cos ϕ = 0.6, I = 5 A, cos ϕ = 1. If the micro switch has switched a voltage > 24 V and a...
Open the catalog to page 11
Technical data 8 Technical data Medium: clean air. The air must be dry in all temperature conditions and must not contain condensate. Opening time: VR..N: quick opening: 0.5 s. VR..L: slow opening: 4 s. VR..R: slow opening: 4 s. Closing time: VR..N: quick closing: < 1 s. VR..L: quick closing: < 1 s. VR..R: slow closing: 4 s. Solenoid coil insulation: class F insulating material. Switching frequency: version without damping unit: any, version with damping unit: with fully operational damping unit, max. 6 switching operations per minute. Valve housing: aluminium, valve disc: Perbunan....
Open the catalog to page 12
Technical data
Open the catalog to page 13
Technical data Data table Type
Open the catalog to page 14
Maintenance cycles 9 Maintenance cycles At least once per year.
Open the catalog to page 15
Feedback Finally, we are offering you the opportunity to assess this “Technical Information (TI)” and to give us your opinion, so that we can improve our documents further and suit them to your needs. Clarity C Found information quickly C Searched for a long time C Didn't find information What is missing? C No answer Comprehension c Coherent c Too complicated c No answer Scope Too little C Sufficient c Too wide c No answer Use V To get to know the product To choose a product Planning To look for information Navigation c I can find my way around C I got “lost" C No answer My scope of...
Open the catalog to page 16All Honeywell Thermal Solutions catalogs and technical brochures
-
Thermal Solutions
12 Pages
-
COMBUSTION CATALOG
176 Pages
-
thermal IQ
4 Pages
-
Magnetic relief valves VAN
4 Pages
-
Tightness controls TC
12 Pages
-
Pressure switches for gas DG
4 Pages
-
Burners for gas BIC, BICA, ZIC
16 Pages
-
Valves and butterfly valves
8 Pages
-
E-SOLUTIONS FOR COMBUSTION™
4 Pages
-
Field bus interface PFA 700
28 Pages
-
Manual valves AKT
4 Pages
-
Gas Pressure Regulator GDJ
2 Pages
-
Gas Pressure Regulator VGBF
4 Pages
-
Thermal equipment trip TAS
4 Pages
-
Safety shut-off valve
2 Pages
-
Relief valves
2 Pages
-
BV.., IB..
8 Pages
-
Gasfilter GFK
4 Pages
-
HTS Engineered to order
8 Pages
-
Training Brochure 2019
17 Pages
-
HONEYWELL COMBUSTION SERVICE
4 Pages
Archived catalogs
-
GIKH
2 Pages
-
GIK
2 Pages
-
IFD 450, IFD 454
34 Pages
-
pb_j78r_60dj_gb
2 Pages
-
pb_tas_akt_tas_gb 2007
6 Pages
-
Gear motors GT
4 Pages
-
Actuators IC 20, IC 40
8 Pages
-
Burner control unit CM 222
4 Pages
-
Control valves S11T
4 Pages
-
Burner control unit BCU 370
6 Pages
-
Product range
4 Pages