This document presents Honeywell's portfolio of analytical measurement and control solutions designed for industrial processes. It emphasizes the importance of precise and reliable measurements of pH, ORP, conductivity/resistivity, dissolved oxygen, and hydrogen purity to improve product quality, process efficiency, equipment maintenance, safety, and environmental compliance.

Key Benefits of Honeywell Analytical Products

  • Consistent product quality
  • Improved process efficiency
  • Reduced equipment maintenance
  • Plant and employee safety
  • Compliance with environmental standards
  • Protection of expensive capital equipment

Product Range and Applications

Honeywell offers a broad range of sensors, analyzers, transmitters, and electrodes suitable for various industrial applications including power generation, chemical processing, wastewater treatment, and pure water monitoring.

Measurement Parameters

  • pH and ORP
  • Conductivity and Resistivity
  • Dissolved Oxygen
  • Hydrogen Purity Concentration

Product Families

  • UDA2182 Series Analyzers: Multi-parameter analyzers supporting pH, ORP, conductivity, dissolved oxygen, and hydrogen purity inputs.
  • APT 2000/4000 Analyzers and Transmitters: Modular analyzers for pH and conductivity measurements with advanced control capabilities.
  • DirectLine Transmitters: Transmitters designed for direct sensor connection with robust signal processing.
  • Meredian® Glass pH Electrodes: High-performance electrodes for reliable pH measurement in diverse conditions.
  • Durafet® pH Electrodes: Solid-state electrodes offering enhanced durability and accuracy.
  • HB/HBD Series Electrodes: High-performance electrodes designed for harsh and demanding environments.
  • DL5000 Dissolved Oxygen Sensors: Sensors optimized for accurate dissolved oxygen measurement.
  • Conductivity Cells and Mountings: Including 4905, 4909, 4973, and 5000TC series for various mounting styles and conductivity ranges.

Installation and Mounting Solutions

Honeywell provides a variety of mounting options to facilitate sensor insertion, removal, and maintenance without process interruption:

  • Ball valve mounting (4909 series) for easy insertion/removal.
  • In-line, flow chamber, or immersion mountings (4905 series) for general-purpose conductivity measurements.
  • Specialized low conductivity mountings (4973 series).
  • Toroidal conductivity cells (5000TC series) for complex industrial processes.

Operating Conditions and Application Environments

Products are categorized based on the severity of operating conditions:

  • EASY: Ambient conditions with neutral pH and moderate conductivity.
  • MODERATE: Elevated temperature and pressure, high purity water applications.
  • HARSH: High temperature, high pressure, and aggressive chemical environments.

Honeywell offers specific product lines tailored to these conditions, ensuring optimal performance and durability.

Technical Highlights and Features

  • Smart sensors and instruments with advanced diagnostics and control capabilities.
  • Wide range of electrodes including multipurpose, combination, and sanitary types.
  • Innovative solid-state pH electrodes (Durafet®) for improved reliability.
  • Comprehensive dissolved oxygen measurement solutions with DL5000 series.
  • Hydrogen purity analyzers for specialized industrial applications.

Summary Table of Products and Compatible Sensors

MeasurementAnalyzer/TransmitterCompatible Sensors/ElectrodesMounting Options
pHDL421, UDA2182, APT4000PH, APT2000PHDL1000, DL2000, 7773, 7774, 7777, 7794DVP, HB/HBD Series, HPW700Various insertion and sanitary mountings
ConductivityDL423, UDA2182, APT4000CC, APT2000CCDL4000, 4973, 4905, 4909/4908, 5000TCIn-line, flow chamber, immersion, ball valve
Dissolved OxygenDL424, DL425, UDA2182, DL5000DL5000 sensorsImmersion and flow mountings
ORPDL422, UDA21827773, 7774, 7777, HB SeriesInsertion mountings
Hydrogen Purity78667866 sensorSpecialized mounting

Best Practices and Recommendations

  • Select sensors and electrodes based on process conditions (temperature, pressure, chemical aggressiveness).
  • Use appropriate mounting hardware to facilitate maintenance and ensure sensor longevity.
  • Leverage Honeywell’s smart sensor diagnostics to optimize process control and reduce downtime.
  • Consult authorized distributors and analytical professionals for product selection and support.

Conclusion

Honeywell’s analytical measurement solutions provide reliable, accurate, and durable instruments and sensors tailored for a wide range of industrial applications. Their comprehensive product portfolio supports improved process control, safety, and cost efficiency, backed by global distribution and expert technical support.

See more

Catalog excerpts

SmartSensors-Analytical-Instruments-2

HONEYWELL INNOVATION AND EXPERTISE Analytical measurements are essential in virtually every industrial process. Precise and reliable measurement and control of pH, ORP, conductivity/resistivity, dissolved oxygen and hydrogen purity will benefit your operation in many ways: • Consistent product quality • Improved process efficiency • Reduced equipment maintenance • Plant and employee safety • Compliance with environmental standards • Protects expensive capital

 Open the catalog to page 2
SmartSensors-Analytical-Instruments-3

 From the primary sensors to the analytical instrument, Honeywell provides a broad portfolio of proven analytical measurement and control solutions to keep your operation running smoothly, efficiently and safely. Best of all, Honeywell’s smart sensors and analytical instruments are available from authorized distributors throughout the world. Knowledgeable analytical professionals are there to assist you—when and where you need them.   ...

 Open the catalog to page 3
SmartSensors-Analytical-Instruments-4

  UDA2182 Series Analyzers                  ...

 Open the catalog to page 4
SmartSensors-Analytical-Instruments-5

  pH is measured in a wide variety of process applications to ensure product quality, monitor effluent discharge and to control addition of chemicals for optimum chemical reaction. Applications include power, chemical process, wastewater and pure water measurements. HPW7000: High Purity Measurement    

 Open the catalog to page 5
SmartSensors-Analytical-Instruments-6

Honeywell conductivity technology helps measure, analyze and transmit valuable conductivity, resistivity and concentration information in simple and complex industrial processes with a complete line of conductivity cells and mountings.   4905: In-Line, Flow Chamber, or Immersion Mountings/General Purpose Conductivity 4973: In-Line or Flow Chamber Mountings for Low Conductivity Measurements DirectLine DL4000 Series    

 Open the catalog to page 6
SmartSensors-Analytical-Instruments-7

Honeywell is an industry proven leader for analytical products and solutions with unique technologies. Innovations in analytical measurements lead to more reliable systems, lower total cost solutions and safer environments. This results in process control that maximizes up-time and minimizes cost to add to your bottom line. Hydrogen Purity Concentration   Durafet® pH Electrodes Meredian® Glass pH Electrodes     ...

 Open the catalog to page 7
SmartSensors-Analytical-Instruments-8

Product Range     Elevated Temperature; Elevated Pressure; 3-11 pH Ambient Conditions; Neutral pH DirectLine pH High Temperature; High Pressure; Very Acidic/Very Basic Ambient Conditions; Conductivities between 20 and 10,000 uS/cm Elevated Temperature; Elevated Pressure; High Purity Water Applications...

 Open the catalog to page 8

All Honeywell Process Solutions catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.