Overview: The ABP2 Series are high-accuracy, compensated, and amplified board mount pressure sensors by Honeywell. They offer both digital and analog outputs, capable of handling liquid media, and are designed for precise pressure readings across a wide range of pressures and temperatures. Calibration and temperature compensation are managed by an on-board ASIC.
Specifications: These sensors cover a pressure range from 6 mbar to 12 bar (600 Pa to 1.2 MPa or 2 inH2O to 175 psi) with a Total Error Band (TEB) as low as ±1.5% FSS, long-term stability of ±0.2% FSS, and accuracy of ±0.25% FSS BFSL. The operating temperature range is from -40°C to 110°C.
Features: Key features include a 24-bit digital I2C or SPI-compatible output, ratiometric analog output, ultra-low power consumption, and compliance with standards such as IPC/JEDEC J-STD-020E, REACH, and RoHS. They are suitable for IoT applications and compatible with various liquid media.
Applications: The sensors are applicable in medical, industrial, commercial, and transportation sectors, including ventilators, HVAC systems, coffee makers, and air brakes.
Value to Customers: The small size simplifies integration into PCBs, reduces design and manufacturing costs, and enhances system performance and reliability. Their flexibility and versatility make them suitable for a wide range of applications.
Differentiation: The ABP2 Series offers application-specific designs, digital outputs for easy integration, and a comprehensive TEB specification that minimizes the need for individual sensor testing and calibration.
Additional Information: The document includes sections on power consumption, digital and analog output versions, nomenclature, pressure range specifications, and recommended pneumatic sensor connections.
Environmental Specifications: The sensors handle 0% to 95% RH non-condensing for external surfaces and up to 100% RH condensing for certain internal surfaces. They are rated for 15 g vibration and 75 g shock, with a life cycle of at least 1 million full-scale pressure cycles.
Pressure Types and Outputs: The sensors measure absolute, differential, and gauge pressures, with both analog and digital outputs available.
Power Consumption: Detailed tables illustrate power consumption for digital and analog versions at different supply voltages and sampling rates.
Nomenclature and Order Guide: A detailed guide for ordering sensors is provided, including product series, package type, pressure port options, and pressure ranges.
Breakout Boards: Information on breakout boards for use with the Honeywell SEB Sensor Evaluation Kit is included.
General Information: The document provides product dimensions, pinout details, and recommended PCB layouts for various package types.
Pinout and Functionality: Pin configurations for I2C and SPI sensors are outlined, detailing the function of each pin.
Start-Up Timing: The sensor is ready to receive commands 2.5 ms after the VDD supply is within operating specifications.
Power Supply Requirement: The system power must meet a minimum VDD rising slope of 10 V/ms.
Reference Circuit Designs: Circuit diagrams for digital and analog output versions are provided, emphasizing noise suppression techniques.
I2C and SPI Communications: Detailed explanations of I2C and SPI communication protocols, including data transfer rates, sensor addressing, and pressure and temperature reading procedures, are provided. Example Arduino codes for interfacing with the sensors are included.
Specifications and Standards: Specifications for O-rings used in pressure manifolds are outlined, adhering to the AS-568 Standard.
Procedures and Recommendations: Emphasis is placed on the buyer's responsibility to determine product suitability for specific applications, with recommended compression ranges for O-rings provided.
Warranty and Liability: Honeywell provides a standard warranty covering defects in materials and workmanship, disclaiming liability for consequential damages.
Warnings: Warnings are issued against using these products as safety or emergency stop devices, highlighting potential risks of personal injury if misused.
Additional Information: Contact details for Honeywell's global network are provided for further assistance, along with references to additional materials available online.
See more

Catalog excerpts

ABP2 SERIES-1

Board Mount Pressure Sensors High Accuracy, Compensated/Amplified 6 mbar to 12 bar | 600 Pa to 1.2 MPa | 2 inH2O to 175 psi Digital or Analog Output, Liquid Media Capable DESCRIPTION The ABP2 Series are piezoresistive silicon pressure sensors offering a digital or analog output for reading pressure over the specified full scale pressure span and temperature range. They are calibrated and temperature compensated for sensor offset, sensitivity, temperature effects and accuracy errors (which include non-linearity, repeatability and hysteresis) using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure and temperature are updated at approximately 200 Hz. All products are designed and manufactured according to ISO 9001 standards. The liquid media option includes an additional gel coating to protect the electronics under port P1, which enables use with non-corrosive liquids (e.g. water and saline) and in applications where condensation can occur. The ABP2 Series is available in tube packaging. Pocket tape and reel packaging is available upon request. • Simplifies design-in: Small size saves room on the PC board (PCB), simplifying design in smaller and lower power devices. Meets IPC/JEDEC J-STD-020E Moisture Sensitivity Level 1 requirements: - Allows avoidance of thermal and mechanical damage during solder reflow attachment and/or repair that lesser rated sensors may incur. - Allows for unlimited shelf life when stored at <30ºC/85 %RH (simplifying storage and reducing scrap). - Eliminates lengthy bakes prior to reflow. - Allows for lean manufacturing due to stability and usability shortly after reflow. • Cost-effective: Small size helps engineers reduce design and manufacturing costs while maintaining enhanced performance and reliability of the systems they design. • Accurate: Total Error Band (TEB) and wide pressure range enable engineers to optimize system performance by improving resolution and system accuracy. • Flexible: Supply voltage range, variety of pressure units, types and ranges, output options, and wide operating temperature range simplify use in the application • Versatile: Wet-media compatibility, low power, and temperature output options make the sensor a versatile choice for Internet of Things applications • Application-specific design ensures suitability for a wide array of customer requirements. • Digital output allows the sensor to be directly plugged into the customer’s circuitry without requiring major design changes • Total Error Band (see Figure 1): - Provides a more comprehensive measurement of performance over the compensated temperature range, which minimizes testing and calibrating every sensor, thereby potentially reducing manufacturing cost; improves sensor accuracy and offers ease of sensor interchangeability due to minimal part-to-part variation. - Improves sensor accuracy - Offers ease of sensor interchangeability due to minimal part-to-part variation POTENTIAL APPLICATIONS • Medical: Ventilators/portable ventilators, CPAP, blood analysis, blood pressure monitoring, breast pumps, drug dosing, hospital beds, massage machines, oxygen concentrators, patient monitoring, sleep apnea equipment, urine analyzers and wound therapy • Industrial: HVAC transmitters, life sciences, material handling, pneumatic control and regulation, process gas monitoring and valve positioning/ positioners • Commercial: Air beds, coffee makers, washing machines, level measurement, dish washers, vacuum cleaners, hand dryers and rice cookers • Transportation: Air brakes, CNG monitoring, fork lifts and fuel level measurement • Total Error Band (see Figure 1): As low as ±1.5 %FSS • Liquid media option: Compatible with a variety of liquid media • Long-term stability: as low as ±0.2 %FSS • Accuracy: ±0.25 %FSS BFSL • Wide pressure range: 6 mbar to 12 bar | 600 Pa to 1.2 MPa | 2 inH2O to 175 psi • High burst pressures • Wide operating temperature range of -40°C to 110°C [-40°F to 230°F] • Calibrated over wide temperature range of -40°C to 110°C [-40°F to 230°F] • 24-bit digital I2C or SPI-compatible output • Ratiometric analog output • IoT (Internet of Things) ready interface • Ultra-low power consumption (as low as 0.01 mW typ. average power, 1 Hz measurement frequency) • Meets IPC/JEDEC J-STD-020E Moisture Sensitivity Level 1 • REACH and RoHS compliant • Temperature output available • NSF-169, LFGB and BPA compliant materials Honeywell offers a variety of board mount pressure sensors for use in potential medical and industr

 Open the catalog to page 1
ABP2 SERIES-2

ABP2 SERIES BASIC BOARD MOUNT PRESSURE SENSORS TABLE OF CONTENTS TOTAL ERROR BAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 GENERAL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 POWER CONSUMPTION AND STANDBY MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 DIGITAL OUTPUT VERSIONS. . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 2
ABP2 SERIES-3

ABP2 SERIES BASIC BOARD MOUNT PRESSURE SENSORS TOTAL ERROR BAND Total Error Band (TEB) is a single specification that includes the major sources of sensor error. TEB should not be confused with accuracy, which is actually a component of TEB. TEB is the worst error that the sensor could experience. Honeywell uses the TEB specification in its datasheet because it is the most comprehensive measurement of a sensor’s true accuracy. Honeywell also provides the accuracy specification in order to provide a common comparison with competitors’ literature that does not use the TEB specification. Many competitors...

 Open the catalog to page 3
ABP2 SERIES-4

ABP2 SERIES BASIC BOARD MOUNT PRESSURE SENSORS TABLE 2. OPERATING SPECIFICATIONS ANALOG Current consumption: I2C sleep/standby mode SPI sleep/standby mode Update/data rate SPI/I C voltage level: low high Total Error Band : 0°C to 50°C -20°C to 85°C -40°C to 110°C Power consumption Operating temperature range Compensated temperature range Startup time Clipping limit for analog version: upper lower MAXIMUM MINIMUM Sensors are not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 2 Operating temperature range: The temperature...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.