Product Overview
Honeywell's Cooling Solutions business unit focuses on high-quality cooling components, including expansion valves, solenoid valves, and filter driers. The Honeywell Operating System (H.O.S.) ensures high quality, flexibility, and fast production, aiming for customer satisfaction.
Specifications and Features
  • Expansion Valves: Control mass flow of refrigerant based on pressure and temperature, with features like adjustable pressure and interchangeable orifice cartridges.
  • Automatic Expansion Valves: Maintain constant evaporation pressure, ideal for single injected evaporators.
  • Thermostatic Expansion Valves: Available with fixed or interchangeable orifice cartridges, used in systems like heat pumps.
Comparative Tables
Includes tables for expansion valves, solenoid valves, sight glasses, and filter driers, providing capacity data for different refrigerants and series to aid component selection.
Additional Information
Direct access to experienced specialists is available for advice via phone or fax.
Key Sections
  • Specifications: Lists series of thermostatic expansion valves with capacity data for refrigerants like R134a and R404A.
  • Capacity Tables: Present orifice size and capacity for different series, aiding in valve selection.
  • Valve Series and Nomenclature: Explains nomenclature and connection options for valves.
  • Solenoid Valves: Details features and specifications, including durability and modularity.
  • Technical Drawings: Provides dimensional drawings for valve series.
  • Additional Notes: Technical specifications may change without notice, with potential differences in aspects like length and pressure.
Critical Information
Emphasizes selecting the correct valve series and orifice size based on application requirements and refrigerant type. Highlights the modularity and durability of solenoid valves for various applications.
Components
  • Check Valves: Prevent flow reversion in lines.
  • Vibration Absorbers: Minimize vibrations and noise.
  • Hot Gas Bypass Valves: Adjust compressor capacity for freezing protection.
  • Liquid Injection Valves: Reduce suction gas temperature.
Electronic Controls
Offers electronic controls for safe operation in cooling and heating applications, including thermostats and temperature displays.
Additional Information
Detailed technical information, data sheets, and selection software are available on Honeywell's website, with contact information for further inquiries.
See more

Catalog excerpts

En3h-1

Cooling Components comparison tables Easy selection of the right components

 Open the catalog to page 1
En3h-2

Reliability and quality for professionals Components of the market leader in many areas Honeywell's business unit „Cooling high quality cooling components. For our customers that means: a broad choice of many innovative and well established expansion valves, solenoid valves and filter driers as well as a good range of other cooling components. In Mosbach, Germany product managers, the sales department, production are working close together focusing on the highest level of customer satisfaction through optimal products. To achieve this goal, H.O.S., the Honeywell Operating System, a big bundle...

 Open the catalog to page 2
En3h-4

Expansion valves Mature valves for various conditions Expansion Valves are used to expand liquid refrigerant from a higher pressure and a higher temperature to a lower pressure controller for superheat, Expan- sion Valves control the refrige- rant mass flow depending on evaporator. They adjust the quantity of the injected refrige- rant exactly and guarantee an economic function by optimal Automatic Expansion Valves Automatic Expansion Valves ex- pand the refrigerant and keep the adjusted evaporation pressure at a constant level. They are typically used for plants with single injected evaporators...

 Open the catalog to page 4
En3h-5

Series TLEX 4.75 - 11 External pressure equalization, MOP charge, warm thermal head, adjustable superheat setting, Balanced Port, solder connections, fixed orifice, orifice size 4.75 to 11. Capillary tube Series TMV(X) External pressure equalization, combi adsorber charge for several refrigerants, adjustable superheat set., flare connections, interchangeable orifice cartridges. Series TMV(X)BL Internal or external pressure equalization, combi adsorber charge for several refrigerants, adjustable superheat setting, inlet flare connection with optional soldering adapter, outlet solder connection,...

 Open the catalog to page 5
En3h-6

Comparative table expansion valves Series TLK/TLE/TLEX/TLESX with fixed orifice Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 6
En3h-7

* For explanations on these series see page 4-5. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.) Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 7
En3h-8

Comparative table expansion valves SeriesTLESX/TLEX with fixed orifice Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 8
En3h-9

SeriesTLESX/TLEX with fixed orifice For explanations on these series see page 4-5. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.) Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 9
En3h-10

Comparative table expansion valves SeriesTMV/TMVL with changeable orifice 1 0 Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 10
En3h-11

SeriesTMV/TMVL with changeable orifice * For explanations on these series see page 4-5. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.) Subject to change without notice ■ EN3H-0375GE23 R0709 "1 "]

 Open the catalog to page 11
En3h-12

Comparative table expansion valves Series TMX with changeable orifice Series Type Valve cartridge Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 12
En3h-13

Series TMX with changeable orifice Series Valve type Orifice size Orifice size * For explanations on these series see page 4-5. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.). Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 13
En3h-15

Series TMVL Valve body head TMVL Valve base VLS(X) Valve base VLS(X) Subject to change without notice ■ EN3H-0375GE23 R0709

 Open the catalog to page 15
En3h-16

Dimensional drawings expansion valves Series TMX TMX Valve body head TMVL TMX TMX TMX TMX XD XBS - Durchgang XDXD Orifice cartridge VD XD XBS - XBS Throughway XBS - Durchgang Valve baseDurchgang XBS - Durchgang XD XBS - Durchgang XLS - Winkel XLS - Durchgang XLS - Winkel XLS - Winkel XLS - Durchgang XLS - Durchgang XLS - Winkel XLS - Durchgang XLS - Winkel Valve base XLS Angle 16 XLS - Durchgang Valve base XLS Throughway Subject to change without notice · EN3H-0375GE23 R0709

 Open the catalog to page 16
En3h-17

Thermo head Pressure equaliser Transfer pin Adjustment of overheating Valve seat Expansion valve TLEX 0.5-4.5 T T T T L L L L K E E X ES X Nomenclature Thermostatic expansion valves (fixed orificies) External pressure equaliser Series of valve Connections (L=solder, B=flare, O=O-ring) T =Thermostatic Expansion valve T T T T T T T MV MV X MV BL MV X BL MV L M X - B M X - L Nomenclature Thermostatic expansion valves (changeable orifices) Connections (L =solder, B = flare) External pressure equaliser Series of valve T = Thermostatic expansion valve Subject to change without notice · EN3H-0375GE23...

 Open the catalog to page 17
En3h-18

Solenoid valves Practice proven design with extreme long lifetime Solenoid Valves are used in general refrigeration and for original equipment as reliable and demand-oriented barrier of line sections. They are suitable for installation into liquid line, hot gas line and suction line of a refrigerating unit. Honeywell Solenoid Valves impress by following advantages: • High durability - minimum 1.5 million alternations of load • Solid protection against humidity by special sealing of the coil • Normally closed • Direct operated: no minimum pressure differential required to open the valve • Pilot...

 Open the catalog to page 18
En3h-19

Solenoid valves Connections (S=solder in inch, MMS=solder in mm, ()=flare) Valve size Design (A = angle - direct operated, D = direct operated, S = pilot operated) For explanations on these series see page 18. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.) Subject to change without notice ■ EN3H-0375GE23 R0709 1 9

 Open the catalog to page 19
En3h-21

All valves on this double-page spread include one 230 V coil and are normally closed (NC). In our part program we offer all products also separately (except of the MD 102). The part program includes a choice of additional coils. angle construction angle construction part program part program part program part program * For explanations on these series see page 18. Please note also that these series of Honeywell could also come with other technical differences (length, weight, maximum pressures, etc.) Subject to change without notice ■ EN3H-0375GE23 R0709 21

 Open the catalog to page 21

All Honeywell Environmental & Combustion Controls EMEA catalogs and technical brochures

  1. V5832B/V5833A

    4  Pages

  2. VSxF-2/-3/-4

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.