Catalog excerpts

Airflow Sensors AWM700 Series, Compensated/Amplified
Open the catalog to page 1
Airflow Sensors The AWM700 Series, Compensated/Amplified Airflow Sensors provide in-line flow measurement with a specially designed bypass flow housing. These sensors measure flow as high as 300 standard liters per minute (SLPM) while inducing a typical pressure drop of 1 inH2O. The AWM700 has a high flow range capability in a small package, as well as a 6 ms response time. These sensors require a 10 Vdc supply, but consume only 60 mW of power. The compact plastic package withstands overpressures of 1720 mbar | 172 kPa | 25 psi without compromising performance. The snap-in AMP-compatible...
Open the catalog to page 2
AWM700 Series, Compensated/Amplified Table 1. Specifications Flow range Excitation voltage Power supply Power consumption Output loading: sinking sourcing Null voltage shift: 25 °C to -25 °C [77 °F to -13 °F] 25 °C to 85 °C [77 °F to 185 °F] Pressure drop at full scale Temperature range: operating storage <0.005 Vdc typ. variation at 5 Vdc excitation between any two directions 25 °C to 5 °C [77 °F to 41 °F] 25 °C to 60 °C [77 °F to 140 °F] Full scale output shift: 25 °C to 10 °C [77 °F to 50 °F] 25 °C to 40 °C [77 °F to 104 °F] 25 °C to 5 °C [77 °F to 41 °F] 25 °C to 60 °C [77 °F to 140 °F]...
Open the catalog to page 3
AWM700 Series, Compensated/Amplified Table 2. AWM720P1 Flow Specifications Pressure Drop Flow (SLPM) Table 3. AWM730B5 Flow Specifications Pressure Drop Flow (SLPM)
Open the catalog to page 4
AWM700 Series, Compensated/Amplified Figure 1. Mounting Dimensions (For reference only: mm/[in].)
Open the catalog to page 5
AWM700 Series, Compensated/Amplified LAMINAR FLOW Due to the fast response time of the sensor, the specifications in this datasheet were generated using laminar flow. Airflow instability or “turbulence” present in the airstream will result in an increase in measurement uncertainty. Turbulent flow may be corrected by either of the following two methods: • Straightening the airflow by using flow laminarizing. • Slowing the response of the sensor by using a simple RC time constant on the output of the sensor. (This will slow down the sensor response time. The values needed depend on the amount...
Open the catalog to page 6
ADDITIONAL INFORMATION The following associated literature is available at sensing.honeywell.com: • Airflow Products Line Guide • Airflow, Force and Pressure Sensors Range Guide • Product Installation Instructions WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this...
Open the catalog to page 7All Honeywell Advanced Sensing Technologies catalogs and technical brochures
-
TBP Series
19 Pages
-
SNDH-H SERIES
4 Pages
-
ABP2 SERIES
42 Pages
Archived catalogs
-
Model QWLC-8M
4 Pages
-
IP Series
7 Pages
-
Magnetic Sensors Line Guide
13 Pages