1. Catalogs
  2. Holykell
  3. UE2000/US8000/US9000

UE2000/US8000/US9000

UE2000/US8000/US9000

UE2000/US8000/US9000

Product catalog summary
Overview: The document provides technical specifications and installation guidelines for the UE Series Explosion Proof Type Ultrasonic Level Meter by HOLYKELL. It highlights the device's robust design, measurement capabilities, and protective features.
Specifications: The ultrasonic level meter is designed for non-contact measurement with high accuracy and reliability. It features an isolated power supply, lightning protection, and overvoltage/overcurrent protection. The device supports various output options, including 4-20mA, 1-5V, and RS485, and is suitable for measuring levels in volatile, flammable, and corrosive environments.
Installation Guidelines: Key installation considerations include avoiding blind areas, ensuring the sensor is not obstructed by walls or feeding holes, and using sun/rain shades for outdoor installations. The sensor should be mounted at a distance from walls to accommodate the ultrasonic beam angle.
Features: The device supports threaded and coil clamping installations, has a beam angle design for accuracy, and is housed in a durable, waterproof, anti-corrosion, and explosion-proof structure. It is equipped with high-quality terminal blocks for long-term stability.
Technical Specifications: The level range varies from 5M to 50M, with accuracy between 0.25%-0.5% F.S. The device operates under a working pressure of 2 Bar (5 Bar for explosion-proof type) and a temperature range of -20 to +80°C. It includes an English language display for various measurements and states.
Wiring and Connections: The document provides detailed wiring instructions for current, voltage, and RS485 connections, specifying wire colors and functions.
Ordering Information: A part number selection table is provided, detailing options for range, cable length, waterproof rating, output type, and power supply. Customization options are available for specific requirements.
See more

Catalog excerpts

UE2000/US8000/US9000-2

UE SERIES Explosion Proof Type Ultrasonic Level Meter US SERIES Universial Type Ultrasonic Level Meter Profiles HOLYKELL’s Ultrasonic level meter have beautiful appearance, stability performance; explore proof design and good measurement function. Isolated power supply by industrial instruments, all of the output, input lines with lightning protection, overvoltage, over current protection circuit functions. Transmitter function of small, weak energy, high sensitivity, bearing small; a complete sensor system can accurately complete the objects in different environments continuous non-contact measurement;...

 Open the catalog to page 2
UE2000/US8000/US9000-3

Features 1.Support M78*2 mm threaded into type installation and coil clamping type installation, the installation more convenient 2.Many model output optional customizable 4-20ma three-wire system, 1-5v, RS485 more customizable 3.Less than 9°C Beam angle design ,Resolution 3mm, less than 200ms responsible time to make sure more accuracy 4.Wide range of application,Sealed high-temperature toxic volatile,flammable and explosive of strongly corrosive liquid medium level measurement of non-contact ultrasonic sensors 5.Housing adopts the NLEPE synthetic material IP66 waterproof,Anti-Skid,Anti-corrosion,Anti-explosion...

 Open the catalog to page 3
UE2000/US8000/US9000-4

Wiring connection Electronic Wires Connection Red

 Open the catalog to page 4
UE2000/US8000/US9000-5

How to Order Part Number Selection Table Selection Type UE2000(Explosion Proof Type) Model US8000 (Integrative Type) US9000 (Segregated Type) Water Proof Power Supply J1 = Relay (Upper & Lower alarm) V1=Voltage output (0-5V) V2= Voltage output (1-5V) R=Digital RS485(MCU Protocol) X=By Customized Cable Length

 Open the catalog to page 5

All Holykell catalogs and technical brochures

  1. HPT604-E11

    8  Pages

  2. HPT604-E8

    8  Pages

  3. HPT604-E5

    8  Pages

  4. HPT604-E3

    7  Pages

  5. HPT200-EX2

    8  Pages

  6. HPT200-EX1

    8  Pages

  7. HPT604-BL

    6  Pages

  8. HRF600-S 2025

    4  Pages

  9. HRF 600 2025

    4  Pages

  10. HPT701 2025

    6  Pages

  11. HK301

    5  Pages

  12. H305V

    3  Pages

  13. 4001

    5  Pages

  14. UF2000-F

    6  Pages

  15. UF2000B

    6  Pages

  16. HTWF

    5  Pages

  17. FLOWMETER

    9  Pages

  18. HPT604H

    3  Pages

  19. HPT604-FW

    5  Pages

  20. HPT612

    6  Pages

  21. HPT603

    6  Pages

  22. HPT611

    6  Pages

  23. HPT608

    6  Pages

  24. HPT607

    6  Pages

  25. HPT606

    6  Pages

  26. UE3008

    4  Pages

  27. HPT605

    6  Pages

  28. UE3005

    6  Pages

  29. UE3003

    5  Pages

  30. UE3002

    4  Pages

  31. UE3001

    5  Pages

  32. HPT613

    6  Pages

  33. HPT604-BM

    6  Pages

  34. HR80G

    8  Pages

  35. HPT675S

    5  Pages

  36. UE3006

    4  Pages

  37. HPT604

    6  Pages

  38. HLM

    4  Pages

  39. HPT708

    6  Pages

  40. HPT601/602

    6  Pages

  41. HPT200-G

    6  Pages

  42. HPT702

    8  Pages

  43. HPT703

    6  Pages

  44. HPT200-HT

    6  Pages

  45. HPT200-EX

    6  Pages

  46. HPT907C

    6  Pages

  47. HPT200

    6  Pages

  48. HPT300-S

    6  Pages

  49. HPT300-C

    6  Pages

  50. HPT906

    6  Pages

  51. HPT700

    6  Pages

  52. HK7 Series

    14  Pages

  53. Flow meter

    9  Pages

  54. HPT621

    6  Pages

Archived catalogs

  1. HRF-600S

    4  Pages

  2. HRF-600

    4  Pages

  3. HPT701

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.