Portable Ultrasonic Water Depth Meter
9Pages

{{requestButtons}}

Catalog excerpts

Portable Ultrasonic Water Depth Meter - 1

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED Portable Ultrasonic Water Depth Meter---HLU-SF 1. Profiles: Holykell HLU-SF ultrasonic water depth meter is used in reservoirs, lakes, rivers or shallow sea water etc. The main principal is to place ultrasonic transducer above water or in water and use ultrasonic spreading in the water to get calculated water depth by instrument. This instrument adopts the international advanced technology, equipped also with water depth measurement functions, control functions, data transfer functions and man-machine communication capabilities. This instrument is a water depth measurement instrument of ultrasonic receive and dispatch sensor, servo circuit, temperature compensation, salinity compensation and compensation circuit unit, monitor, and control signal output and serial data or analog output unit (optional). Its main advantages are high reliability, long life, easy access, simple operation, accurate measurement of features and less-maintenance, it has already been widely used in the hydrographic survey, hydropower plant, reservoir area, shallow seas, lakes, rivers, surveying, environmental waters monitoring etc. ■ the water depth meter has different compensation of water quality and water sound temperature for sea water, river water, and cost performance are surpassed import type. ■Standard configuration of instrument: 1. Sensor; 2. handheld instrument, high-capacity lithium-ion battery (built-in), 3.Dedicated charger. Can be selected a variety of portable protective box when you ordering. Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: admin@holykell.com Website: Http://www.holykell.com Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of Chin

Open the catalog to page 1
Portable Ultrasonic Water Depth Meter - 2

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 2. Instrument composition and port definition Sensor Lead Connect thread Sensor Sensor.connection nec tion Wall-hung con nect Charge Port Signal Output Charge Port Signal Output and wiring Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: admin@holykell.com Website: Http://www.holykell.com Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of Chin

Open the catalog to page 2
Portable Ultrasonic Water Depth Meter - 3

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 3. Maximum Range: 100m, 200m, 300m (default 100m, can be customizable ) Detection accuracy: ± 0.5% FS (based on 20 °C water standard plane) Blind Zone Detection: ≤ 500 to 800mm (at F0 ~ FS, according to the sensor range) Draft depth: ≥ 500mm Detection methods: of 0.1 ~~ 100Hz / s (without special requirements, 1Hz / s is default) Beam angle: 18 °± 2 ° Operating frequency: 50kHz~200kHz (based on matching sensor dependent) Output signal: 4 ~20 mA, RS485 (can be customizable) Instrument operating parameters: Dispaly: LCD multi-information screen+...

Open the catalog to page 3
Portable Ultrasonic Water Depth Meter - 4

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 4. Instrument display and keyboard definition: Show Value(m) Output display of analog or temp Netaddress indicate Baud rate indicate Analog output indicate Switching value output Serial port communication 示 Fault report and type indicate ■ Keyboard definition: Addend key: press this key and add "1" of blink digit number then determine the decimal point in setting status, when you need negative numbers operation, Press to tune out or remove the negative sign; Press the key for 5 seconds in working status you can turn off the display and access a...

Open the catalog to page 4
Portable Ultrasonic Water Depth Meter - 5

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 5. Menu operation: Menu Press flip over key in working status will display P1, press the shift key again, will enter P1 menu, the menu is as follows: The first limit alarm output: no use. The second limit alarm output: ditto. The third limit alarm output: ditto. The fourth limit alarm output: ditto. Draft depth Settings, set one half of the negative distance between the surface to depth sensor emission face into the menu, it will automatically count the draft depth when the instrument display depth of water. Parameter setting method: press shift...

Open the catalog to page 5
Portable Ultrasonic Water Depth Meter - 6

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 6. Installation dimension of sensor: 【The following picture is the schematic diagram of sensor body, the final size and appearance is subject to the real goods】 ◆Installation suggestion: sensor installation should consider the protection requirements of the cable, we suggest to make cable through the pipe, then connect pipe to sensor connector, other external fittings can connect the pipe directly. In order to avoid cable fracture to cause permanent damage of sensor, cable should be avoid under the stress of the installation of fittings....

Open the catalog to page 6
Portable Ultrasonic Water Depth Meter - 7

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 8. Communication protocol of Serial port: 【Standard Baud rate】 Half duplex asynchronous mode, Baud rate can be set freely from 600 to 19200 BPS. MC version communication format (standard Baud rate). 1: Host machine: After sending address (1 ~ 64)of binary code then inquire receiving data. 2: Slave: to response by interrupt mode, each frame sending 21 byte. Sending data Sequence of Slave: First 5 bytes is water depth value (5 bytes ASC code, the unit is meter) The sixth to twentieth bytes is production testing code (no business of the user); the...

Open the catalog to page 7
Portable Ultrasonic Water Depth Meter - 8

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED sound... gauge or power driver has been damaged. 1. The depth of water meter installed too 1. Adjust the sensor’s axis and make inclined, reflection is not good; it perpendicular to the water surface 2. The power setting too big, and then caused remaining vibration or diffraction power P is about 10, above 30 m numerical value range, power P is about 10 ~ 15 3. Don't properly used in air 4. There are two or more than two sets distance change... of water depth meter are working in 4. Move another instrument close, causing echo interference; distant...

Open the catalog to page 8
Portable Ultrasonic Water Depth Meter - 9

MANUAL HOLYKELL TECHNOLOGY COMPANY LIMITED 4~20mA output is abnormal: it is too high or too low, display 10 mv ... has been illegally modified; 2.The output fine adjustment parameter AX has been illegally modified; 2. Contact the distributor or the manufacturer to set correct parameter; 3. Charging in time. 3. Low battery. 1.Check the host and extension set, 1. The setting of extension baud rate is adjust Baud rate to be consistent; The water depth meter of not consistent with the setting of host 2.Check host’s Ar value, make the extension address does not upper host or PC cannot be...

Open the catalog to page 9

All Holykell catalogs and technical brochures

  1. HK301

    5 Pages

  2. H305V

    3 Pages

  3. 4001

    5 Pages

  4. UF2000-F

    6 Pages

  5. UF2000B

    6 Pages

  6. HTWF

    5 Pages

  7. HRF-600

    4 Pages

  8. HRF-600S

    4 Pages

  9. FLOWMETER

    9 Pages

  10. HPT604H

    3 Pages

  11. HPT604-FW

    5 Pages

  12. HPT612

    6 Pages

  13. HPT603

    6 Pages

  14. HPT611

    6 Pages

  15. HPT608

    6 Pages

  16. HPT607

    6 Pages

  17. HPT606

    6 Pages

  18. UE3008

    4 Pages

  19. HPT605

    6 Pages

  20. UE3005

    6 Pages

  21. UE3003

    5 Pages

  22. UE3002

    4 Pages

  23. UE3001

    5 Pages

  24. HPT613

    6 Pages

  25. HPT604-BM

    6 Pages

  26. HR80G

    8 Pages

  27. HPT675S

    5 Pages

  28. UE3006

    4 Pages

  29. HPT604

    6 Pages

  30. HLM

    4 Pages

  31. HPT708

    6 Pages

  32. Sensor Cells

    4 Pages

  33. HPT601/602

    6 Pages

  34. HPT200-G

    6 Pages

  35. HPT702

    8 Pages

  36. HPT703

    6 Pages

  37. HPT200-HT

    6 Pages

  38. HPT200-EX

    6 Pages

  39. Sensor Cells

    4 Pages

  40. HPT907C

    6 Pages

  41. HPT200

    6 Pages

  42. HPT300-S

    6 Pages

  43. HPT300-C

    6 Pages

  44. HPT906

    6 Pages

  45. HPT700

    6 Pages

  46. HK7 Series

    14 Pages

  47. HPT701

    6 Pages

  48. Flow meter

    9 Pages

  49. HPT621

    6 Pages

Archived catalogs