HPT702
1 /8Pages

HPT702

HPT702
1 /8Pages

Catalog excerpts

HPT702-2

HPT 702 Standard Industry Air Differential Pressure Transmitter Applications · HAVC Air differential pressure · Wind pipe pressure measurement · Wind machine · Industrial dust removal equipment · Purification plant · Blow down expander · Leak detection device Characters · Min 1 Pa gas pressure sensitive · Digital temperature compensation · Germany silicon chips assembled · Anti-humidity and water proof · IP65 enclosure · Advanced circuit linearity compensation · CE approving Profiles HPT702 differential pressure transmitter is precision engineered for monitoring differential pressure of air and...

 Open the catalog to page 2
HPT702-3

Specifications Ambient Temperature: 25° (unless specified) C Parameter Pressure Range Safe overload Burst Pressure Accuracy (Linearity/hysteresis/ repeatability) Long Time Stability Working Temp Storage Temp Temperature compensation Zero Point Temp Drift Full Scale Temp Drift Medium compatible ≥5 kPa, compatible with 316L liquids Electronic Wire Power Supply Load resistance R=(U-12.5) / 0.02-RD (RD is cable inner resistance) Electronic connection Fixed cable outlet Proof grade Pressure connect port Response time Adjustment Pressure Type Support adjustable zero and span. Around 0.2KG (excluding...

 Open the catalog to page 3
HPT702-5

Electronic Connections RS485 output wiring diagram

 Open the catalog to page 5
HPT702-6

Pressure method The default pressure port is φ8 gas mouth, in which the long nozzle is the high-end pressure port and the short nozzle is the low-end pressure port. (Φ6 gas mouth or quick connector can also be used) Zero and Full Scale Adjustment There are two types of wind differential pressure transmitter with potentiometer and without potentiometer. If the user chooses the potentiometer hole (the user can manually adjust the zero position. Note: If there is no standard pressure source, do not move the full-scale potentiometer, otherwise it will affect the accuracy of the transducer), uses...

 Open the catalog to page 6
HPT702-7

How to Order 1. Pressure Range Selection Table: 01 Kindly according to your application select suitable range code , Example: Code 16 =3kPa . Unit of measure select on the Part Number Selection Table . Example: Code K=kPa , that’s 3 kPa. 2. Part Number Selection Table: Selection Type Signal output Power supply Pressure connection Range reference to pressure range selection table code. Pressure unit C=LCD E=LED Pressure range 31=Ø8 gas mouth with M10*1.5 male thread X= By Customized Cable length

 Open the catalog to page 7
HPT702-8

Accessories (Notes: Purchased separately. For the price of accessories, please contact our sales.) Order number Liquid level display control device With all kinds of liquid level sensor, measurement according to liquid level, and according to the setting of the container structure and size and the density of liquid, calculation, display liquid volume or quality. Adapter Converter It is able to convert RS-232 signal to RS-485 balanced differential signal and extend the communication distance to 1.2km.It uses a particular pump to gain power from RS-232 signal (RTS, DTR, TXD) without initializing...

 Open the catalog to page 8

All Holykell catalogs and technical brochures

  1. HPT604-BL

    6  Pages

  2. HRF600-S 2025

    4  Pages

  3. HRF 600 2025

    4  Pages

  4. HPT701 2025

    6  Pages

  5. HK301

    5  Pages

  6. H305V

    3  Pages

  7. 4001

    5  Pages

  8. UF2000-F

    6  Pages

  9. UF2000B

    6  Pages

  10. HTWF

    5  Pages

  11. FLOWMETER

    9  Pages

  12. HPT604H

    3  Pages

  13. HPT604-FW

    5  Pages

  14. HPT612

    6  Pages

  15. HPT603

    6  Pages

  16. HPT611

    6  Pages

  17. HPT608

    6  Pages

  18. HPT607

    6  Pages

  19. HPT606

    6  Pages

  20. UE3008

    4  Pages

  21. HPT605

    6  Pages

  22. UE3005

    6  Pages

  23. UE3003

    5  Pages

  24. UE3002

    4  Pages

  25. UE3001

    5  Pages

  26. HPT613

    6  Pages

  27. HPT604-BM

    6  Pages

  28. HR80G

    8  Pages

  29. HPT675S

    5  Pages

  30. UE3006

    4  Pages

  31. HPT604

    6  Pages

  32. HLM

    4  Pages

  33. HPT708

    6  Pages

  34. HPT601/602

    6  Pages

  35. HPT200-G

    6  Pages

  36. HPT703

    6  Pages

  37. HPT200-HT

    6  Pages

  38. HPT200-EX

    6  Pages

  39. HPT907C

    6  Pages

  40. HPT200

    6  Pages

  41. HPT300-S

    6  Pages

  42. HPT300-C

    6  Pages

  43. HPT906

    6  Pages

  44. HPT700

    6  Pages

  45. HK7 Series

    14  Pages

  46. Flow meter

    9  Pages

  47. HPT621

    6  Pages

Archived catalogs

  1. HRF-600S

    4  Pages

  2. HRF-600

    4  Pages

  3. HPT701

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.