1. Pressure Measurement 2. Level Measurement 3. Temperature Measurement 4. Flow Measurement 5. Display & Control Instruments 6.Wireless Monitoring Systeih 7.Velocity Measurement
Open the catalog to page 1DATASHEET- level MEASUREMENT HPT 604-E3Threaded Pressure Level Sensor | Applications • Irrigation Equipment • Sea Water Level Measurement and Control • Deep Well and Groundwater Monitoring • Vessel and Storage Monitor Systems • Control of Lift and Pumping Stations • Level Measurement in OilTanks • Monitoring of Gasoline & Diesel FuelTanks | Features • High accuracy pressure sensor up to 0.5%F.S • 316L stainless steel diaphragm, 316L body construction shock and erosion • Custom level ranges from 50cmto 200m • Customization installation thread • IP68 full sealed waterproof design • Lightning and...
Open the catalog to page 2DATASHEET- level MEASUREMENT | Specifications Ambient Temperature: 25°C (unless specified) Polarity Protection The power lines feature reverse polarity protection; however, the signal lines do not have reverse polarity protection against the positive power supply and must not be cross-connected. Zero-point Temp. drift 0.01%FS/°C Full scale Temp. drift 0.005%FS/°C Process Connection G1/2'' male, M20*1.5 male, 1/4''NPT male; M10*1 male; Flange mounting, 2'', 3'', 4'' flange Electrical Connection Response Time Pressure Type Explosion-proof Protection EMC Standard Fixed cable with vented tube and...
Open the catalog to page 3DATASHEET- level MEASUREMENT
Open the catalog to page 4DATASHEET- level MEASUREMENT | Electronic Connections Wire color
Open the catalog to page 5DATASHEET- level MEASUREMENT 1. Range Selection Table: Kindly according to your application select suitable range code , Example: code 23 = 10 . Unit of measure select on the Part Number Selection Table . Example: Code H=m H2O, that's 10m H2O . 2. Part Number Selection Table: Selection Type Range 23 H G E5 S60 3 CW N 2 003 Range reference to range selection table code I= inWC (Min: 20 inWC; Max: 8000 inWC ) MB= mbar (Min: 50 mbar Max: 20000 mbar) G=Gauge/Relative pressure type (universal) Pressure Type A=Absolute pressure (customiZed) Signal Output 6=G1/4'' male (Typical) 8=M20x1.5 male 26=1/4''-18...
Open the catalog to page 6•DATASHEET* LEVEL MEASUREMENT Order number Liquid level display control device 0008 With all kinds of liquid level sensor, measurement according to liquid level, and according to the setting of the container structure and size and the density of liquid, calculation, display liquid volume or quality. Desiccant drying cartridge Desiccant Pack installed on Vented sensor cable.The cartridge will have to be field replaced as site environment requires. Locking flange For locking cables, made of aluminum alloy Surge electrostatic protector Anti-surge ±2000V/±4000V, anti-static 18KV, suitable for protecting...
Open the catalog to page 78 Pages
8 Pages
8 Pages
8 Pages
7 Pages
8 Pages
8 Pages
7 Pages
8 Pages
8 Pages
8 Pages
6 Pages
35 Pages
4 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
15 Pages
5 Pages
9 Pages
3 Pages
3 Pages
5 Pages
5 Pages
6 Pages
6 Pages
5 Pages
3 Pages
9 Pages
3 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
6 Pages
6 Pages
5 Pages
4 Pages
5 Pages
6 Pages
6 Pages
8 Pages
5 Pages
4 Pages
5 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
14 Pages
6 Pages
9 Pages
6 Pages