HPT200-EX2PRESSURE• DATASHEET* 1. Pressure Measurement 2. Level Measurement 3. Temperature Measurement 4. Flow Measurement 5. Display & Control Instruments 6.Wireless Monitoring System 7.Velocity Measurement
Open the catalog to page 1HPT200-EX2Fully Welded Pressure Sensor| Applications • Oil, gas applications • Drilling platforms and pipeline • Refineries and petrochemical industry • Marine and vessel approved • Diesel tank level monitoring • Hydraulic and pneumatic system • Harsh and hazardous application • 316L stainless steel diaphragm Welded SUS316L Body construction • High degree of EMC/EMI protection • Strong shock and erosion resistance • Ex ia IIC T5 Ga, ATEX / IECEx approved • Custom absolute and gauge (relative) versions The HPT200-EX2 intrinsically safe pressure sensor is designed for use in hazardous environments,...
Open the catalog to page 2| Specifications Ambient Temperature: 25°C (unless specified) Zero-point Temp. drift 0.01 %FS/°C Pressure Connection G1/4''male, G1/2''male, 1/4'‘NPT male, 1/2'‘NPT male optional Electrical connection 1/2''NPT male thread with cable-outlet Endurance >100 million cycles, 0...100 %FS at25°C Explosion-proof Protection Custom oil filling fluorocarbon oil (O2-compatible), olive-oil, lowest temperature oil (-55°C)
Open the catalog to page 30.5-4.5V Proportion and Non-Proportional Signal (3-Wires, Voltage Output):
Open the catalog to page 5| Electrical Connection Wire color Warning: The shielding wire must be grounded, do not discard. Pressure Connections
Open the catalog to page 62. Part Number Selection Table: Kindlyaccording to your application select suitable range code , Example: code 08 =10 . Unit of measure select on the Part Number Selection Table . Example: Code B=Bar, that's 10 bar. Output Signal Power Supply S6=5 V DC S60=10-28VDC X=By customized 1=7/16-20 UNF male 3= 1/4” NPT male 8= M20x1.5 male 2=7/16-20 UNF Female 6=G1/4” male 9=G1/2” male Other Option C=Anti-corrosive Type O=Oxygen Services X=Withstand Xylene N=Standard Type LengthXXX= Cable XXX m (Cable length refers to I.S Parameter Table)
Open the catalog to page 7DATASHEET- PRESSURE MEASUREMENT (Notes: Please purchase separately. For the price of accessories, please contact our sales.) Order number Liquid level display control device With all kinds of liquid level sensor, measurement according to liquid level, and according to the setting of the container structure and size and the density of liquid, calculation, display liquid volume or quality. Terminal box The terminal box, with IP67 and watertight ventilation element, provides a moisture-free electrical termination for the submersible pressure transmitter. It should be mounted in dry environment or...
Open the catalog to page 88 Pages
8 Pages
8 Pages
7 Pages
8 Pages
7 Pages
8 Pages
8 Pages
7 Pages
8 Pages
8 Pages
6 Pages
35 Pages
4 Pages
4 Pages
6 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
15 Pages
5 Pages
9 Pages
3 Pages
3 Pages
5 Pages
5 Pages
6 Pages
6 Pages
5 Pages
3 Pages
9 Pages
3 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
6 Pages
6 Pages
5 Pages
4 Pages
5 Pages
6 Pages
6 Pages
8 Pages
5 Pages
4 Pages
5 Pages
6 Pages
4 Pages
6 Pages
4 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
14 Pages
6 Pages
9 Pages
6 Pages