H8000 Series Multipurpose Colorful Date Paperless Recorder
35Pages

{{requestButtons}}

Catalog excerpts

H8000 Series Multipurpose Colorful Date Paperless Recorder - 1

H8000 Series Multipurpose Colorful Date Paperless Recorder (For Pressure, Level, Temperature, Humidity, Flow…. Data logger, display, record and Control) HOLYKELL TECHNOLOGY COMPANY LIMITED

Open the catalog to page 1
H8000 Series Multipurpose Colorful Date Paperless Recorder - 2

I. Overview Holykell 8000 series Color paperless recorder can input signals, such as standard voltage, standard current, thermoelectric couple, resistance temperature detector and millivolt, etc; it can be based on 18-channel alarm output or 12-channel analog quantity output, RS232/485 communication interface, Ethernet interface, mini-printer interface, USB interface and SD card socket; sensor distribution can be provided; it is characterized by powerful display function, real-time curve display, historical curve recall, bar graph display and alarm list display, as well as humanized...

Open the catalog to page 2
H8000 Series Multipurpose Colorful Date Paperless Recorder - 3

Data backup Support USB and SD card for data backup and transfer, maximum capacity: 8GB, support FAT and FAT32 formats. Storage capacity Internal Flash storage capacity: 64M Byte Time interval of recording Time duration of storage (Continuous record without power failure) Operating environment Working power Recordingtime(days)= (! Note: Calculation of channel number: The program will divide the channel into five classes of 4, 8, 16, 32 and 64. When the channel number falls within the range of two classes, the bigger one should be taken. If, for instance, the channel number is 12, the number...

Open the catalog to page 3
H8000 Series Multipurpose Colorful Date Paperless Recorder - 4

●When switching on/off power, please take out the storage medium. ●For the general matters needing attention of the storage medium, refer to the operating instructions. 3.2 Instrument installation 3.2.1 Installation site It should be installed at the following places: ● Subpanel: The instrument is a panel mounting one ●Installation place: It should be installed indoors to avoid wind, rain and sunshine. ●Well ventilation: To prevent the internal temperature from rising, it should be installed at a well-ventilated place. ●Infrequent mechanic vibration It should be installed at a place with...

Open the catalog to page 4
H8000 Series Multipurpose Colorful Date Paperless Recorder - 5

Installation method ●Installation dimension (Unit: mm) ●Installation of instrument (1)Installation method A. Input the instrument from the front of the panel B. Install the instrument according to the installing support attached to the instrument as shown below: ▲Fix four installing supports to the two sides of the instrument (2)For the installation, refer to the r

Open the catalog to page 5
H8000 Series Multipurpose Colorful Date Paperless Recorder - 6

●Wiring diagram Terminal diagram of instrument tail Wiring that Ⅳ. Ordering Instruction H81□-□-□-□-□ 12-channel input ① ② ③ ④ ⑤ H87□-□-□-□-

Open the catalog to page 6
H8000 Series Multipurpose Colorful Date Paperless Recorder - 7

①Number of Input Channel ② Number of Transmitting Output Channel (remark) Input channel Output channel 1-channel input 2-channel input 3-channel input . . . 47-channel input 48-channel input No output 1-channel output 2-channel output 3-channel output . . . 11-channel output 12-channel output ③ Number of Alarm Output Channel (remark) ④Power Supply Alarm channel Voltage range No output 1-limit alarm 2-limit alarm 3-limit alarm . . . 17-limit alarm 18-limit alarm ⑤Additional functions (You can select all the following functions with ―/‖ to separate them, and can omit the unselected...

Open the catalog to page 7
H8000 Series Multipurpose Colorful Date Paperless Recorder - 8

Ⅴ. Function and operation Paperless Recorder large information content and convenient configuration, the multi-channel temperature controller is equipped with multiple operating display screens and configuration screens. Therefore, the user can operate the instrument without training. Power on the instrument and display the initial picture of the system and then enter the digital picture after the completion of system initialization. Various display pictures and configuration pictures are described as follows: 5.1 Switching of running screen The running screen consists of real-time curve...

Open the catalog to page 8
H8000 Series Multipurpose Colorful Date Paperless Recorder - 9

①:Time scale: Time duration of each grid. Time scale is connected with time interval. Fore more information, refer to the following table: 1 second 16min utes/gr id 32min utes/gr id 64min utes/gr id 30mi nute /grid 1ho ur/gr id 2ho urs/ grid 4ho urs/ grid 12min ute/gri d 24min utes/gr id 48min utes/gr id 96min utes/gr id time interval Time scale ②:Data curve: At most 6 curves can be displayed on the same screen. (The six curve colors can be set by displaying configuration.) ③:Grid: It can be convenient for the user to estimate time and data. ④:Current time represented by the grid ⑤:Curve...

Open the catalog to page 9
H8000 Series Multipurpose Colorful Date Paperless Recorder - 10

⑾:Operating key: Press the ―Switch‖ to switch to other display pictures. Press ―Time Scale‖to switch time scale. Press ―Previous‖to check the previous curve combination. Press ―Next‖ to check the next curve combination If you press ―Cycle‖, the ― ‖circular icon will appear on the screen; if you press the circular time interval in the display combination, it will switch to the next curve combination automatically. 5.4 Bar graphics The six channel data and percentile bar graphics can be displayed at the same time. ①: Name of channel: It means the corresponding engineering location number of...

Open the catalog to page 10
H8000 Series Multipurpose Colorful Date Paperless Recorder - 11

5.5 Digital pictures Multiple real-time data and alarm statuses can be displayed at the same time. ①:Name of channel: Display the engineering location number of the channel (settable). (For the setting method, refer to Section 5.12.4.1 Input Method of Channel Location Number.) ②:Data of work amount: Current data of work amount. ③:Indication of limit alarm: From the top to the bottom, each diamond refers to high-high limit, high limit, low limit and low-low limit. Gray means no alarm function; green means no alarm has been given; red/pink means an alarm. ④:Unit: Display the unit of the...

Open the catalog to page 11
H8000 Series Multipurpose Colorful Date Paperless Recorder - 12

5.6 Historical curve pictures According to the setting of the curve combination, the historical data curve of six channels can be displayed at the same time (curve accuracy: 0.5%± character). 1 ①:Time scale: Time duration of each grid. Time scale is connected with recording time interval. For more information, refer to the description of real-time curve picture. ②: Data curve: At most six curves can be displayed on the same screen at the same time. (The six curve colors can be set through the display configuration.) ③:Grid: Convenient for the user to estimate time and data. ④:Time of the...

Open the catalog to page 12

All Holykell catalogs and technical brochures

  1. HK301

    5 Pages

  2. H305V

    3 Pages

  3. 4001

    5 Pages

  4. UF2000-F

    6 Pages

  5. UF2000B

    6 Pages

  6. HTWF

    5 Pages

  7. HRF-600

    4 Pages

  8. HRF-600S

    4 Pages

  9. FLOWMETER

    9 Pages

  10. HPT604H

    3 Pages

  11. HPT604-FW

    5 Pages

  12. HPT612

    6 Pages

  13. HPT603

    6 Pages

  14. HPT611

    6 Pages

  15. HPT608

    6 Pages

  16. HPT607

    6 Pages

  17. HPT606

    6 Pages

  18. UE3008

    4 Pages

  19. HPT605

    6 Pages

  20. UE3005

    6 Pages

  21. UE3003

    5 Pages

  22. UE3002

    4 Pages

  23. UE3001

    5 Pages

  24. HPT613

    6 Pages

  25. HPT604-BM

    6 Pages

  26. HR80G

    8 Pages

  27. HPT675S

    5 Pages

  28. UE3006

    4 Pages

  29. HPT604

    6 Pages

  30. HLM

    4 Pages

  31. HPT708

    6 Pages

  32. Sensor Cells

    4 Pages

  33. HPT601/602

    6 Pages

  34. HPT200-G

    6 Pages

  35. HPT702

    8 Pages

  36. HPT703

    6 Pages

  37. HPT200-HT

    6 Pages

  38. HPT200-EX

    6 Pages

  39. Sensor Cells

    4 Pages

  40. HPT907C

    6 Pages

  41. HPT200

    6 Pages

  42. HPT300-S

    6 Pages

  43. HPT300-C

    6 Pages

  44. HPT906

    6 Pages

  45. HPT700

    6 Pages

  46. HK7 Series

    14 Pages

  47. HPT701

    6 Pages

  48. Flow meter

    9 Pages

  49. HPT621

    6 Pages

Archived catalogs