1. Catalogs
  2. Hollysys
  3. AFM2000 SERIES METAL TUBE ROTAMETER
video corpo

AFM2000 SERIES METAL TUBE ROTAMETER

AFM2000 SERIES METAL TUBE ROTAMETER
1 / 18 PagesView full catalog

AFM2000 SERIES METAL TUBE ROTAMETER

Product catalog summary
Terms and Conditions
  • Notice for Use: The AFM2000 Series Metal Tube Rotameter is intended for measuring steam, clean gases, and liquids in harsh conditions, but not suitable for media with solid particles or high viscosity. Users must ensure the device's suitability and corrosion resistance for their applications.
  • Safety of Use: Proper installation and adherence to explosion-proof requirements are essential for safe operation.
  • Copyright and Technical Support: Owned by HollySys, users are encouraged to contact the company for technical support.
Product Description
  • Introduction: The AFM2000 series is a modular, metal tube rotameter with features like small volume, low pressure loss, and high accuracy, suitable for various industrial applications.
  • Features: Includes modular design, explosion-proof capabilities, flexible measurement methods, and multiple power sources. Supports HART and Modbus communication protocols.
  • Structure and Principle: Composed of a measuring tube and an indicator, using magnetic coupling and sensors to measure flow, providing outputs like 4-20mA and supporting communication protocols.
  • Technical Parameters: Covers a wide range of diameters and pressure levels, with various wetted materials available for different media and conditions.
Specifications
The document outlines specifications for the AFM2000 Series, including ambient and medium temperature ranges, signal output options, power supply types, explosion-proof levels, protection class, medium viscosity, and display methods. It operates in ambient temperatures from -40℃ to 120℃, with medium temperatures up to +350℃ under specific conditions. Signal output options include two-wire 4~20mA output and Hart communication, with power supply options of 24VDC, 220VAC, and a 3.6V-9Ah lithium battery. Rated for IP65 protection, it has specific viscosity limits for different diameters.
Product Models and Measuring Range
The AFM2000 Series includes models AFM2000-4, AFM2000-5, and AFM2000-6 R/L, with diameters from DN15 to DN150. The measuring range for water at 20℃ is 16~150,000 L/h, and for air at 20℃ and 0.1013MPa, it is 0.5~4,000 m3/h. The range ratio is standard at 10:1, with some models offering 20:1. Accuracy levels are specified at 1.0 and 1.5.
Installation and Materials
Installation forms include vertical, side-side, bottom, thread, jacket, and horizontal installations. Wetted materials are selected based on medium corrosion conditions, including options like 316, 304, 316L, PTFE lining, Hastelloy C-276, and Titanium alloy. Additional structures include sanitary, damping, jacket type, high temperature, high pressure, and communication options.
Indicators
Various indicators are available, including M41, M42, M43, M44, M45, and MK1/MK2, each with specific functions such as on-site indication, LCD display, and alarm capabilities. They can operate with different power supplies and output configurations.
Damping Device and Mounting Accessories
Damping devices are recommended for conditions with low operating pressure, unstable pressure, or significant changes in pipe diameter. Magnetic filters and straight pipe sections are suggested to prevent ferromagnetic particles from affecting the rotor's movement.
Electrical Connections
Electrical connections should be made with the power off, following explosion-proof and safety regulations. The recommended cable diameter is 8 to 13mm, with specific wiring instructions for different indicator models.
Installation Requirements
  • Ensure the pipe is clean before installation to prevent impurities from affecting the float.
  • Maintain a distance from magnetic fields to avoid zero deviation issues.
  • Install the device vertically or horizontally with minimal inclination and ensure proper alignment of upstream and downstream pipes.
  • Use appropriate torque for bolts to avoid damage to PTFE lining.
  • Include bypass pipes for maintenance and ensure valves are installed for flow regulation.
Maintenance
  • Ensure the rotor operates flexibly and check for loose positioning screws.
  • Indicators are specific to each measuring tube and are not interchangeable.
  • Regularly check the pointer for correct indication and adjust if necessary.
  • Detect and troubleshoot output current deviations and ensure proper alignment of pointer and shaft limit ring.
  • Follow specific steps for converter detection and adjustment, ensuring power supply and anti-interference measures are in place.
Key Tables and Diagrams
  • Tables provide dimensions and weight for various models, torque specifications for bolts, and connection sizes for food-grade applications.
  • Diagrams illustrate installation setups and flow direction requirements for different rotameter models.
Power Supply Requirements
The voltage must be stable and pure to prevent peak pulse interference during large equipment operations. In case of power failure, power on the instrument only after the device is powered on.
Cable Requirements
Use shielded cables for onsite instruments, ensuring proper grounding separate from electrical ground. Instrument and power cables should be laid separately.
Load Requirements
The output current load should range from 250 ohms to 750 ohms. Loads greater than 750 ohms can reduce output current, while loads less than 250 ohms decrease anti-interference ability. A 250-ohm resistance can be added for small loads.
Current Output Problem Detection
Check for issues with indicators, fastening screws, pointers, and flowmeter floats. Ensure zero pointer indicates RP and regulate current as needed.
Switch Plate Indicator and Alarm Detection
Ensure indicator flexibility and check coordination with the switch plate starter. Adjust the pointer fan board if necessary.
AFM2000 Series Metal Tube Rotameter
Maintenance is generally not needed unless ferromagnetic particles cause float sticking. If this occurs, remove the rotameter to clear blockages. Ensure the float operates freely and check for system operation stability issues such as unstable flow rate, small pressure differences, incorrect flow meter range, or two-phase flow.
Calibration and Maintenance
Factory calibration is usually sufficient. If zero offset occurs, adjust installation direction and position. Avoid removing the indicator to prevent deviation.
Caliber and Measurement Range
No absolute correspondence exists among valve sizes, pump angles, flow rate, or pressure. Use correction factors to determine flow rates and select appropriate rotor calibers and measurement ranges based on user parameters.
Correction Factor Calculations
Various formulas are provided to calculate correction factors for liquid and gas volume flows under different conditions, considering medium density and temperature.
See more

Catalog excerpts

AFM2000 SERIES METAL TUBE ROTAMETER-1

AFM2000 Series Metal Tube Rotameter HOLLYSYS GROUP. ALL RIGHTS RESERVED USER MANUAL 产品展示 AFM2000 SERIES METAL TUBE ROTAMETER HollySys Group (Group Headquarters) No.2 Di Sheng Middle Road, Economic-Technological Development Area, Beijing 100176 Tel: +86 10 58981000 Fax: +86 10 58981100 Hangzhou HollySys Automation Co., Ltd. (Industrial Automation Headquarters) No.1 North No.19 Street, Qiantang District, Hangzhou 310018 Tel: +86 571 81633600 Fax: +86 571 81633700 HollySys (Asia Pacific) Pte. Ltd. (International Headquarters) Changi Business Park Crescent, #04-01/02/03 Plaza 8 @ CBP, Tower A, Singapore 486025 Tel: +65 6777 0950 Fax: +65 6777 2730 HollySys Automation India Pvt. Ltd. D-84, Ground Floor, Sector 63, Noida, Uttar Pradesh 201301 Tel: +91 12045 50652 * Read this manual before using the product PT. HollySys Automation Indonesia Metropolitan Tower, 10th Floor Unit E, Jl. R.A. Kartini Kav. 14, Jakarta 12430 Tel: +62 21 2918 2926 Fax: +62 21 2918 2936 Web: www.hollysys.com E-mail: [email protected] (Sales) [email protected] (After-sales Service) Version: Jun-2023 2

 Open the catalog to page 1
AFM2000 SERIES METAL TUBE ROTAMETER-2

AFM2000 Series Metal Tube Rotameter Contents 1. Terms and Conditions ……………………… 1 1.3 Copyright ………………………………………………… 1 Founded in 1993, HollySys is a leading supplier of intelligence solutions with more than 4,700 employees and operates in both China and abroad. HollySys is headquartered in Beijing with R&D, production, and service bases in Beijing, Hangzhou, Xi'an, Singapore, and local branches in major cities in China, as well as offices in India, Malaysia and Indonesia, establishing a comprehensive service network across the world. HollySys business consists of industrial intelligence, transpor...

 Open the catalog to page 2
AFM2000 SERIES METAL TUBE ROTAMETER-3

AFM2000 Series Metal Tube Rotameter Metal tube rotameter is also known as variable-area rotameter (hereinafter referred to as instrument). It can be used to measure steam, continuous clean gases and liquids, especially to measure and control small flow with low velocity in harsh medium conditions. It is not suitable for measuring media containing solid particles or of high viscosity. Please contact us when ordering the instrument to confirm whether the instrument meets its requirements if the medium conditions are quite bad. AFM 2000 series metal tube rotameter is a variable-area flow instrument...

 Open the catalog to page 3
AFM2000 SERIES METAL TUBE ROTAMETER-4

AFM2000 Series Metal Tube Rotameter AFM2000 series metal tube rotameter is composed of two parts: LCD: Measuring tube - magnetic coupling, sensor; Indicator - signal converting, conditioning, scale indication or number display. There are four types of wetted materials of the measuring tube: stainless steel, Hastelloy, titanium, stainless steel lining PTFE; Users can choose different wetted materials according to different process pressure and corrosion requirements of media, to meet the needs of pressure resistance and media anticorrosion. According to different measurement requirements, users...

 Open the catalog to page 4
AFM2000 SERIES METAL TUBE ROTAMETER-5

AFM2000 Series Metal Tube Rotameter Technical Parameters Product Model Instrument diameter Measuring range Technical Parameters Product Model Meter diameter Measuring range Range ratio Range ratio Standard: 250mm (Please consult the manufacturer about the particular one) Wetted materials R0 (316) R1 (304) RL (316L) RP (PTFE lining) RC (Hastelloy C) RT (Ti titanium lining) Standard: 250mm (Please consult the manufacturer about the particular one) Wetted materials Pressure level Pressure level Standard: DN15~DN50 4.0MPa please consult the manufacturer about the particular one Standard: DN15~DN100...

 Open the catalog to page 5
AFM2000 SERIES METAL TUBE ROTAMETER-6

AFM2000 Series Metal Tube Rotameter Technical Parameters Product Model Meter diameter Ambient temperature Medium temperature Intrinsically Safe: Exia II CT6 Ga Flameproof: Exd II CT6 Gb IP65 Medium viscosity On-site pointer display; LCD Electrical connections Vertical installation, bottom in and up out Vertical installation, up in and bottom out Side - side installation, bottom side in and up side out Bottom installation, bottom in and up out Thread installation, bottom in and up out (only DN15 ~ DN100) Jacket Installation, bottom in and up out (only DN15 ~ DN100) Select the corresponding installation...

 Open the catalog to page 6
AFM2000 SERIES METAL TUBE ROTAMETER-7

AFM2000 Series Metal Tube Rotameter 2.8 Indicator With different modules, M4 indicator has different functions. Rotor material: 1 □ R0, R1, RC Caliber Rotor size Displayed variables of indicators with LCD can be set. Please see the commissioning instruction for further information. The maximum pressure loss ②――Shafting subassembly ③――Rail bracket fastening screws ④――Rail bracket ⑤――Nameplate The key function: The indicator and sensor cooperate to realize on-site indication without external power supply. ②――Signal transmission module ③――Terminals ④――Rail bracket ⑤――Operation buttons ⑥――Nameplate...

 Open the catalog to page 7
AFM2000 SERIES METAL TUBE ROTAMETER-8

AFM2000 Series Metal Tube Rotameter ③――LCD mounting plate ④――Conversion module and a power outlet ④――Rail bracket ⑥――Rail bracket ⑥――Operation buttons ⑦――Operation buttons ⑧――Outlet connector The key function: It can realize LCD and indication with sensors, 3.6V DC power supply and no output. The key function: it can realize LCD and indication with sensors, 220VAC power supply and 4-20mA output (Hart communication or Modbus communication). ①――Pointer ②――LCD ④――Conversion module and 24V DC power outlet ②――Alarm pointer ③――LCD mounting plate ④――Rail bracket ⑤――Rail bracket ⑤――Limit switch board...

 Open the catalog to page 8
AFM2000 SERIES METAL TUBE ROTAMETER-9

AFM2000 Series Metal Tube Rotameter 2.9 Indicator structure and its disassembly Locking operculum Dial Set screw Conversion module Nameplate Tragschienenmodule Liquid crystal plate Under these circumstances, the medium flows in the measuring tube of the rotameter extremely unstably, and the rotor jumps up and down because the three forces on it cannot reach the equilibrium state. The moving rotor is transmitted through the magnetic coupling system to make the pointer' s shafting change, which finally causes continuous and non-stop swing of the pointer and large output range. The user cannot read...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.